Specifications 

Electrical 

Primary input .............. 110-120, 200-240Vac @ 50-60Hz 

RS-422 Converter Input from Transformer 

Primary input ...................................... 24Vac @ 50-60Hz 
Power consumption ......................................... 20W max. 
Allowable line drop.................................................150ms 

Environmental 

Operating temperature:.............0° to 50°C (32° to 122°F) 
Relative humidity: .................... 0 to 90% non-condensing

 

Mechanical 

Height ...................................................... 38.5mm (1.5in) 
Width .......................................................435mm (17.1in) 
Depth ........................................................ 129mm (5.1in) 
Weight ......................................................1.5kg (3.3 lbs.) 

 

Declarations 

Regulatory Compliance 

REG ID: RS422 
EMC........................................................47 CFR, Part 15 
 ICES-003 
 EN55022 

(CE) 

Immunity ................................................ EN50082-1 (CE) 
Safety ......................................................... UL 1950 (UL) 
 

cUL CSA C22.2 No. 950 

 

EN 60950 (CE) 

FCC COMPLIANCE:

 This equipment complies with Part 15 of the 

FCC rules for intentional radiators and Class A digital devices when 
installed and used in accordance with the instruction manual. 
Following these rules provides reasonable protection against harmful 
interference from equipment operated in a commercial area. This 
equipment should not be installed in a residential area as it can radiate 
radio frequency energy that could interfere with radio 
communications, a situation the user would have to fix at their own 
expense. 

EQUIPMENT MODIFICATION CAUTION:

 Equipment changes 

or modifications not expressly approved by Sensormatic Electronics 
Corporation, the party responsible for FCC compliance, could void the 
user's authority to operate the equipment and could create a hazardous 
condition. 

WARNING!

 North America power requirements: In North America, 

this device is intended to be supplied from a Class 2 power supply. 
This installation should be made by a qualified service person and 
should conform to all local codes. 

WARNING!

 EU power requirements: This product runs on 24Vac. In 

the EU, it is intended to be powered from a Limited Power Source. A 
limited power source is a certified source of SELV, and if inherently 
limited, with 8 amps maximum output current, and a maximum of 
100VA available; or if not inherently limited, fused with a maximum 
value of 3.3 Amps, meeting section 2.11 of IEC950, and a maximum 
of 250VA available. The power supply can be obtained through 
American Dynamics or through another source where the provider can 
furnish the verification. This is required to assure electrical safety in 
the product. 

Stromanforderungen in der EU:

 Dieses Produkt wird mit 24 V 

Wechselstrom betrieben. In der EU ist es für den Betrieb durch eine 
begrenzte Stromquelle vorgesehen. Eine begrenzte Stromquelle ist 
eine zertifizierte SELV-Quelle (Schutzkleinspannung), bei inhärenter 
Begrenzung mit einem maximalen Ausgangsstrom von 8 A und 100 
VA maximaler Verfügbarkeit, bei nicht inhärenter Begrenzung mit 
einer maximalen Sicherung von 3,3 A gemäß Abschnitt 2.11 der 
IEC950 und 250 VA maximaler Verfügbarkeit. Das Netzteil kann über 
American Dynamics oder eine andere Quelle bezogen werden, wobei 
der Anbieter den Nachweis der Konformität bereitstellen sollte. Dies 
ist zur Gewährleistung der elektrischen Sicherheit des Produktes 
erforderlich. 

Other Declarations 

Thank you for using American Dynamics products. We support our 
products through an extensive and worldwide network of dealers. The 
dealer, through whom you originally purchased this product, is your 
point of contact if you have a need for service or support. Our dealers 
are fully empowered to provide the very best in customer service and 
support. Dealers should contact American Dynamics at 
(800) 507-6268 or (561) 912-6259 or on the web at 
www.americandynamics.net. 

WARRANTY DISCLAIMER:

 Sensormatic Electronics Corporation 

makes no representation or warranty with respect to the contents 
hereof and specifically disclaims any implied warranties of 
merchantability or fitness for any particular purpose. 

NOTICE: 

The information in this manual was current when 

published. The manufacturer reserves the right to revise and improve 
its products. All specifications are therefore subject to change without 
notice. 

LIMITED RIGHTS NOTICE:

 For units of the Department of 

Defense, all documentation and manuals were developed at private 
expense and no part of it was developed using Government Funds. 
The restrictions governing the use and disclosure of technical data 
marked with this legend are set forth in the definition of “limited 
rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. 
Unpublished - rights reserved under the Copyright Laws of the United 
States. 

TRADEMARK NOTICE:

 

American Dynamics

 and 

Sensormatic

 are 

trademarks or registered trademarks of Sensormatic Electronics 
Corporation. Other product names mentioned herein may be 
trademarks or registered trademarks of Sensormatic or other 
companies. 

COPYRIGHT:

 Under copyright laws, the contents of this manual 

may not be copied, photocopied, reproduced, translated or reduced to 
any electronic medium or machine-readable form, in whole or in part, 
without prior written consent of Sensormatic Electronics. 
MDR 8/05 

www.americandynamics.net 

Содержание RCSN422

Страница 1: ...tallation The converter can be placed on a tabletop or installed in a rack under a shelf or on a wall Parts Supplied Install Kit 0351 1635 01 which includes Mounting Bracket 2 Screw PHP M3x8 4 Connect...

Страница 2: ...First blink indicates a successful ROM check second blink indicates a successful RAM check LED illuminates continuously when either check fails stopping the test Remains illuminated during program loa...

Страница 3: ...EU ist es f r den Betrieb durch eine begrenzte Stromquelle vorgesehen Eine begrenzte Stromquelle ist eine zertifizierte SELV Quelle Schutzkleinspannung bei inh renter Begrenzung mit einem maximalen A...

Страница 4: ...instructions For just the ping test refer to MegaPower LT operation instructions MP LTHB 1 Note If a controller requests device information from a camera having the same address as the converter the c...

Страница 5: ...L 860 AP J Box To MiniDome To Unicard SpeedDome To Optima To Optima LT To SpeedDome Ultra Pigtail To SpeedDome Ultra I O J1 10 J5 P3 P1 P7 Pin 1 TX Pin 1 RX Pin 7 RX Pin 1 RX Pin 1 RX Pin 6 RX Pin 1 R...

Страница 6: ...Dome Ultra Pigtail To SpeedDome Ultra I O J1 10 J5 P3 P1 P7 Pin 1 TX Pin 1 RX Pin 7 RX Pin 1 RX Pin 1 RX Pin 6 RX Pin 1 RX Pin 2 TX Pin 2 RX Pin 6 RX Pin 2 RX Pin 2 RX Pin 7 RX Pin 2 RX Pin 3 AC Pin 3...

Страница 7: ...y it to c program files AD_Utilities Note This file must be F2814 0102 or higher 3 Set the code converter to address 32 4 Launch the ADCASNET utility and click Load Utility 5 Click the Scan Network ic...

Отзывы: