NOTICE
PLAYBACK
OPERATION
RECORDING
OPERATION
PREPARATION
36
INTRODUCTION
ENGLISH
REC Trigger Output Selection in the Alarm
Recording
REC Trigger output can be selected during the alarm recording.
1
Press the DISPLAY
button.
2
Press the
SHIFT
button to blink SETUP.
3
Press the + SET button.
4
Press the
SHIFT
button.
And press the + SET
button to set the REC
trigger SEL.
USAGE TIME TOTAL 0H
HEAD 0H
S E T U P
REC TRIGGER SEL. FIXED
MENU=[DISPLAY]
M E N U
CLOCK ADJUST
SETUP
SETUP
DISPLAY MODE
END=[DISPLAY]
PROGRAM
ALARM RECALL
TIME DATE SEARCH
M E N U
CLOCK ADJUST
SETUP
DISPLAY MODE
END=[DISPLAY]
PROGRAM
ALARM RECALL
TIME DATE SEARCH
5
Press the DISPLAY
button twice to erase the
display.
17:30:02 A 3
28/8/96 WED
RESTART REC OFF
TAPE END MODE STOP
ALARM STOP
S E T U P
1SHOT REC FIELD 1F
MENU=[DISPLAY]
INTERVAL 0.2S
ALARM REC TIME 15S
SPEED A 3H
■
Change to SETUP Screen (1).
■
Each time the + SET button is pressed, the display
changes as follows.
→
FIXED
→
PULSE
DISPLAY
TIME MODE
SET
SHIFT
TRACKING
LOCATION SELECT
+
–
DISPLAY
TIME MODE
SET
SHIFT
TRACKING
LOCATION SELECT
+
–
DISPLAY
TIME MODE
SET
SHIFT
TRACKING
LOCATION SELECT
+
–
DISPLAY
TIME MODE
SET
SHIFT
TRACKING
LOCATION SELECT
+
–
DISPLAY
TIME MODE
SET
SHIFT
TRACKING
LOCATION SELECT
+
–
ENGLISH
REC TRIGGER SEL.
FIXED
PULSE
Normal Recording
A3
LOW (0V)
PULSE (*1)
A12 ~ 960
PULSE (*1)
PULSE (*1)
A12 ~ A24
HIGH (5V)
PULSE (*1)
One shot Recording
L01 ~ L03
PULSE (*1)
PULSE (*1)
Alarm Recording
A3
HIGH (5V)
PULSE (*1)
PULSE (*1) detail
Record mode
Record mode
a
b
5V
0V
A3
20
36 ~ 44
168
40
1120 ~ 1160
a (ms)
b (ms)
a (ms)
b (ms)
L01 ~ L03
40
Depend on the condition
A18
40
56 ~ 64
480
40
3200 ~ 3240
A12
40
96 ~ 104
240
40
1600 ~ 1640
A24
40
170 ~ 190
720
40
4800 ~ 4840
48
40
330 ~ 350
960
40
6400 ~ 6440
120
40
810 ~ 830
72
40
490 ~ 510
Содержание ADR8045X
Страница 50: ...49 INTRODUCTION ENGLISH PREPARATION RECORDING OPERATION PLAYBACK OPERATION NOTICE MEMO...
Страница 51: ......