American Dynamics AD1202 Скачать руководство пользователя страница 3

The installation of this product should be made by qualified

service personnel and should conform to all local codes.

QA301D

!

W

W

W

WA

A

A

ARRRRNN

N

NIIIINN

N

NGGG

G

To reduce the risk of fire or shock hazard, do 

not expose this product to rain or moisture.

AMERICAN

DYNAMICS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, 

DO NOT REMOVE COVERS (OR BACK) .

NO USER-SERVICEABLE PARTS INSIDE.  

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION

!

The lightning flash with arrowhead

symbol, within an equilateral

triangle, is intended to alert the

user to the presence of uninsulated

"dangerous voltage" within the

product's enclosure that may be of

sufficient magnitude to constitute a

risk of electric shock to persons.

The exclamation point within an

equilateral triangle is intended to

alert the user to the presence of

important operating and maintenance

(servicing) instructions in the

literature accompanying the product.

UUU

UNN

N

NPPPPA

A

A

ACCCCKKK

KIIIINN

N

NGGG

G    A

A

A

ANN

N

NDD

D

D    IIIINN

N

NSSSSPPPPEEEECCCCTTTTIIIIO

O

O

ONN

N

N

Unpack carefully.  This is an electronic product and should

be handled as such.  Compare the items received with the

packing list with your order.

Be sure to save:

1.  The shipping cartons and insert pieces.  They are the    

)

     safest material in which to make future shipments of 

     the product.

2.  The IMPORTANT SAFEGUARDS sheet.

3.  These Installation and Operating Instructions.

M

M

M

MA

A

A

AIIIINN

N

NTTTTEEEENN

N

NA

A

A

ANN

N

NCCCCEEEE

User maintenance of this unit is limited to external cleaning

and inspection.  For specific recommendations refer to the

IMPORTANT SAFEGUARDS sheet packaged with this product.

IIIIN

N

N

NSSSSTTTTA

A

A

ALLLLLLLLA

A

A

ATTTTIIIIO

O

O

ONN

N

N    A

A

A

ANN

N

NDD

D

D    SSSSEEEERRRRV

V

V

VIIIICCCCEEEE

If you require information during installation of this

product or if service seems necessary, contact the

Sensormatic Repair and Service Department at (800)

442-2225.  You must obtain a Return Authorization Number

and shipping instructions before returning any product for

service.

Do not attempt to service this product yourself.  Opening or

removing covers may expose you to dangerous voltages or

other hazards.  Refer all servicing to qualified personnel.

This equipment has been tested and

found to comply with Part 15 of the

FCC Rules.

Operation is subject to the

following two conditions: 1. This

device may not cause harmful

interference, and 2. This device

must accept any interference

received, including interference

that may cause undesired operation.

Содержание AD1202

Страница 1: ...Controller The AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site Each camera can be individually controlled from AD1202 front panel switc...

Страница 2: ...is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATI...

Страница 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Страница 4: ......

Страница 5: ...y Reset 6 Camera Selection 6 Camera Programming 6 Preset Scene Programming 7 Video Input Termination 7 Coax Code Selection 7 OPERATION 8 Controlling Camera Site Functions 8 Camera Pan Tilt Control 8 C...

Страница 6: ......

Страница 7: ...mming controls This capability prevents inadvertent changes to camera programming A built in test procedure provides verification of AD1202 front panel controls and indicators FEATURES Individual cont...

Страница 8: ...ideo source is incorrectly unterminated or double terminated coax control will not function properly Looping Video Outputs The AD1202 provides a passive looping output for each camera video input via...

Страница 9: ...TPUT The AD1202 provides an open collector output pulse on pin 15 Alarm Out when an alarm input is received The pulse is held active until the alarm input clears with a minimum of five seconds duratio...

Страница 10: ...ller leave pin 21 open unconnected For operation as a control follower connect pin 21 to ground pin 16 22 or 24 Code Select pin 23 This pin selects the type of coax control code Standard or Enhanced U...

Страница 11: ...camera Each button has two positions fast and slow for use with variable speed pan tilt units When the button is pressed near the center the smaller arrow head the pan tilt action is set to slow spee...

Страница 12: ...mera 2 input 3 for camera 3 and input 4 for camera 4 Each AD1202 input can be programmed to follow any of 16 camera numbers Note To program the AD1202 camera inputs the camera address binary output fr...

Страница 13: ...mera Receiver not in the AD1202 Note The front panel controls must be enabled for preset programming see Programming Blocking page 5 To program and store a preset scene 1 Select the desired camera by...

Страница 14: ...address is provided via the BIN IN pins and the AD1202 automatically selects the camera input programmed for this address The monitor output of the switch should be used to view the selected inputs N...

Страница 15: ...ng to the desired auxiliary number 1 4 The AUX LED turns off Alarm Response There are four alarm inputs on the rear panel EXTERNAL connector see page 3 Each alarm input corresponds to one of the four...

Страница 16: ......

Страница 17: ...Appendix...

Страница 18: ...te simultaneously signifying that the switch closure was recognized by the unit If the LED s flash when a button is pressed one or more buttons may be shorted and the unit is not operating properly 4...

Страница 19: ...Typical System Connections...

Страница 20: ...14 16 18 20 22 24 LOCAL MONITOR AD1641U COAX RECEIVER AD1641U COAX RECEIVER AD1641U COAX RECEIVER NOTE AD1641U Receivers shown for illustration Any AD Receiver with Coax control may be connected in th...

Страница 21: ...IVER AD1641U COAX RECEIVER AD1641M RECEIVER W B S AD1641M RECEIVER W B S PAN TILT NOTE AD1641 Series Receivers shown for illustration Any AD Receiver with Coax or AD Manchester Control Code may be con...

Страница 22: ...de may be connected in this manner If using an AD1645U do not connect pins 2 3 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 HI Z 75 TERM 1 2 3 4 NOTE AD1202 set for Manual Camera Selection See page 3...

Страница 23: ...RECEIVERS AD1641U COAX RECEIVER AD1641U COAX RECEIVER I N AUX 1 4 5 8 120V 60HZ 1 2 3 4 5 6 7 8 B O U T A O U T MD 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 1 2 3 4 HI Z 75 TERM 1 2 3 4 DATA 120V...

Страница 24: ......

Страница 25: ...Index...

Страница 26: ......

Страница 27: ...Control Code Outputs 4 Alarm Inputs 3 Alarm Output 3 Camera Address Output 3 Channel Select Output 3 Code Select Control Pin 4 External Unit Control Pin 4 Factory Reset 6 FEATURES 1 FOCUS Button 5 FR...

Страница 28: ......

Страница 29: ...Camera not terminated properly Check termination of associated camera input pg 7 too dark or bad color Camera iris is not adjusted correctly Adjust camera iris using calibrated monitor Black horizont...

Страница 30: ......

Страница 31: ...tonio Cork Ireland Aguadilla P R 00690 Declares that the product s listed below Name Type MCS Coax Controller Model Number ADS1202X comply with the EMC Standards EN55022 Class B EN50082 1 and also com...

Страница 32: ...rol Code outputs Alarm Inputs Four alarm contact closures Normally Open one input per camera Alarm Output One alarm output TTL open collector pulse Mounting Desktop or Rack mount with AD2117 21 kit Di...

Отзывы: