American Dynamics AD1202 Скачать руководство пользователя страница 29

Problem

Possible Causes

Suggested Action

Operating Problems

Cannot program camera numbers or

Programming Blocking feature enabled

Check and enable front panel controls (page 5)

preset scenes

No AD1202 indicators illuminate

No power to AD1202

Check AC power cord, connection, and source

LEDabove select button 1 is 

Two or more buttons are pressed at

Perform built-in test on pg A-2. If all LEDs flash

permanently illuminated; does

the same time

rapidly, take 1/4 turn of all #4 nuts holding down

not respond to any button pressed

the front panel PCB.

Alarmed camera not being called 

Alarm connections not wired in parallel to

Wire alarm connection to both the switcher and 

to  the external switchers monitor nor

switcher and controller

coax follower (pg. 9)

activation of audio alert

No preset called during alarms

Preset 1 never set

Set preset 1 (pg. 7)

After the alarmed camera has been

External unit pin (pin 21) not grounded

Ground pin 21 (pg. 6)

acknowledged at the switcher, the LED 
still flashes at the AS1202

No control of four auziliaries

Receiver driver connected; cannot respond to

Check manually for auxiliary settings

all auxiliariesa

Video Problems

No picture on Monitor

Monitor/Camera not connected

Check monitor/camera connections

Monitor/camera not powered on or not properly set  up

Verify monitor/camera operation and adjustment

Video pictures too bright, 

Camera not terminated properly 

Check termination of associated camera input 

(pg 7)

too dark, or bad color

Camera iris is not adjusted correctly

Adjust camera iris using calibrated monitor

Black horizontal lines through 

Faulty camera sync or video output

Exchange affected camera with a known good one

picture, or picture not stable

Unit is in external mode and the

Monitor output of AD1202 is incorrectly used

Use monitor output of switcher when in external

monitor output of the AD1202 

unit mode

is displaying the last camera selected

Camera Control Problems

Externally selected camera

AD1202 camera numbers not programmed

Program AD1202 inputs for the desired camera

does not  respond

numbers (refer to pg. 6)

Binary inputs not connected correctly

Check physical connection and confirm proper
wiring (pg. 3)

AD1202 not in External unit mode

Select ground pin 21 (external unit)

Erratic movement of pan/tilt

Coax Code type not set correctly

Check type of coax code (Enhanced or Standard)

and set Coax Code Selection accordingly (page 7)

Incorrect response to key presses

Coax Code type not set correctly

Check type of coax code (Enhanced or Standard)

and set Coax Code Selection accordingly (page 7)

No movement of the pan/tilt connected

Camera not properly terminated; coax code type not

Check termination switch ( page 7)

to the VCR receiver drivers 

set correctly

IF YOU ENCOUNTER ANY PROBLEMS OPERATING

THIS UNIT, OR NEED ASSISTANCE, CALL OUR

TECHNICAL SUPPORT CENTER:

within the United States:  1-800-442-2225

outside the United States:  (914) 624-7640

AD1202

TROUBLESHOOTING

Содержание AD1202

Страница 1: ...Controller The AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site Each camera can be individually controlled from AD1202 front panel switc...

Страница 2: ...is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATI...

Страница 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Страница 4: ......

Страница 5: ...y Reset 6 Camera Selection 6 Camera Programming 6 Preset Scene Programming 7 Video Input Termination 7 Coax Code Selection 7 OPERATION 8 Controlling Camera Site Functions 8 Camera Pan Tilt Control 8 C...

Страница 6: ......

Страница 7: ...mming controls This capability prevents inadvertent changes to camera programming A built in test procedure provides verification of AD1202 front panel controls and indicators FEATURES Individual cont...

Страница 8: ...ideo source is incorrectly unterminated or double terminated coax control will not function properly Looping Video Outputs The AD1202 provides a passive looping output for each camera video input via...

Страница 9: ...TPUT The AD1202 provides an open collector output pulse on pin 15 Alarm Out when an alarm input is received The pulse is held active until the alarm input clears with a minimum of five seconds duratio...

Страница 10: ...ller leave pin 21 open unconnected For operation as a control follower connect pin 21 to ground pin 16 22 or 24 Code Select pin 23 This pin selects the type of coax control code Standard or Enhanced U...

Страница 11: ...camera Each button has two positions fast and slow for use with variable speed pan tilt units When the button is pressed near the center the smaller arrow head the pan tilt action is set to slow spee...

Страница 12: ...mera 2 input 3 for camera 3 and input 4 for camera 4 Each AD1202 input can be programmed to follow any of 16 camera numbers Note To program the AD1202 camera inputs the camera address binary output fr...

Страница 13: ...mera Receiver not in the AD1202 Note The front panel controls must be enabled for preset programming see Programming Blocking page 5 To program and store a preset scene 1 Select the desired camera by...

Страница 14: ...address is provided via the BIN IN pins and the AD1202 automatically selects the camera input programmed for this address The monitor output of the switch should be used to view the selected inputs N...

Страница 15: ...ng to the desired auxiliary number 1 4 The AUX LED turns off Alarm Response There are four alarm inputs on the rear panel EXTERNAL connector see page 3 Each alarm input corresponds to one of the four...

Страница 16: ......

Страница 17: ...Appendix...

Страница 18: ...te simultaneously signifying that the switch closure was recognized by the unit If the LED s flash when a button is pressed one or more buttons may be shorted and the unit is not operating properly 4...

Страница 19: ...Typical System Connections...

Страница 20: ...14 16 18 20 22 24 LOCAL MONITOR AD1641U COAX RECEIVER AD1641U COAX RECEIVER AD1641U COAX RECEIVER NOTE AD1641U Receivers shown for illustration Any AD Receiver with Coax control may be connected in th...

Страница 21: ...IVER AD1641U COAX RECEIVER AD1641M RECEIVER W B S AD1641M RECEIVER W B S PAN TILT NOTE AD1641 Series Receivers shown for illustration Any AD Receiver with Coax or AD Manchester Control Code may be con...

Страница 22: ...de may be connected in this manner If using an AD1645U do not connect pins 2 3 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 HI Z 75 TERM 1 2 3 4 NOTE AD1202 set for Manual Camera Selection See page 3...

Страница 23: ...RECEIVERS AD1641U COAX RECEIVER AD1641U COAX RECEIVER I N AUX 1 4 5 8 120V 60HZ 1 2 3 4 5 6 7 8 B O U T A O U T MD 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 1 2 3 4 HI Z 75 TERM 1 2 3 4 DATA 120V...

Страница 24: ......

Страница 25: ...Index...

Страница 26: ......

Страница 27: ...Control Code Outputs 4 Alarm Inputs 3 Alarm Output 3 Camera Address Output 3 Channel Select Output 3 Code Select Control Pin 4 External Unit Control Pin 4 Factory Reset 6 FEATURES 1 FOCUS Button 5 FR...

Страница 28: ......

Страница 29: ...Camera not terminated properly Check termination of associated camera input pg 7 too dark or bad color Camera iris is not adjusted correctly Adjust camera iris using calibrated monitor Black horizont...

Страница 30: ......

Страница 31: ...tonio Cork Ireland Aguadilla P R 00690 Declares that the product s listed below Name Type MCS Coax Controller Model Number ADS1202X comply with the EMC Standards EN55022 Class B EN50082 1 and also com...

Страница 32: ...rol Code outputs Alarm Inputs Four alarm contact closures Normally Open one input per camera Alarm Output One alarm output TTL open collector pulse Mounting Desktop or Rack mount with AD2117 21 kit Di...

Отзывы: