American Dynamics AD1202 Скачать руководство пользователя страница 11

FRONT PANEL CONTROLS

The following front panel controls are provided for operator
control of a camera site (see Figure 5).  The use of these
controls is described in the SETUP and OPERATION sections
of this manual, pages 6 through 9.

Channel Select Group

1, 2, 3, and 4 -  Selects either a camera (site) to control, a

preset scene to set or call, or an auxiliary to activate.

The illuminated LED above each button indicates the
channel selected, either manually or by a switcher.

PRESET Group

SET -  Allows the operator to store a preset scene for the

selected camera site.

CALL -  Allows the operator to recall a preset scene for the

selected camera.

The illuminated LED's above the SET and CALL
buttons indicate the selected action.

AUX Group

ON -  Allows the operator to activate an auxiliary function

for the selected camera site.

OFF -  Allows the operator to turn off an auxiliary function

for the selected camera site.

The illuminated LED's above the ON and OFF buttons
indicate the selected action.

Note:  Operation of the OFF button is valid only when in

Enhanced Mode or AD Manchester mode.  Standard
Mode can only activate four momentary auxiliaries.

Programming Group

PGM -  Enters Camera Programming (page 6) to program

the AD1202 for specific camera numbers for use with a
compatible AD switcher.

The illuminated LED above the PGM button indicates
camera programming operation.

SEL -  Programs a selected AD1202 camera number for use

with a compatible AD switcher.

The LED above the SEL button illuminates while the
button is pressed.  This LED also indicates an illegal
programming action while programming blocking is in
effect (see Programming Blocking).

Pan and Tilt Group

Four arrow buttons control the pan and tilt movement of the
camera.  Each button has two positions, fast and slow, for
use with variable speed pan/tilt units.

When the button is pressed near the center (the smaller
arrow head), the pan/tilt action is set to slow speed.

When the button is pressed near the outside (the larger
arrow head), the pan/tilt action is set to fast speed.

Lens Control Group

ZOOM -  Controls the camera lens zoom on a motorized

lens unit, TELE (telephoto) or WIDE (wide angle).

FOCUS -  Controls the camera lens focus on a motorized

lens unit, NEAR or FAR.

IRIS -  Controls the camera lens Iris on a motorized lens

unit, OPEN or CLOSE.

Programming Blocking

A programming blocking feature disables the front panel
control functions from programming camera numbers and
preset scenes (see Setup, pages 6 and 7).  This capability
prevents inadvertent changes to camera or preset scene
programming.

To disable (block) programming functions:

First, press the PGM button.  While holding down the PGM
button press the Channel Select buttons “2”, “3”, “2”, “3”.

After this sequence is entered, the Camera and Preset Scene
Programming functions (pages 6 and 7) are disabled.  If the
operator attempts to begin a preset scene sequence and
presses the PGM button the LEDs above PGM and SEL
will steadily illuminate.  Likewise, if a camera
programming sequence is attempted by pressing the SET
button, the LEDs above SET and SEL flash. 

To enable all front panel control functions:

First, press the PGM button.  While holding down the PGM
button press the Channel Select buttons “1”, “4”, “1”, “4”.

After this sequence is entered, all setup programming and
operating functions are enabled.

Note:  If the unit is operating as a coax controller in a stand-

alone configuration with pin 23 unconnected, camera
programming is permanently blocked (see page 6). 

5

AD1202

FRONT PANEL CONTROLS

MCS

1

2

3

4

CLOSE

OPEN

IRIS

FAR

NEAR

FOCUS

WIDE

TELE

ZOOM

PRESET

CALL

SET

AUX

OFF

ON

SEL

PGM

Figure 5 - AD1202 Coax Controller Front Panel Controls

Содержание AD1202

Страница 1: ...Controller The AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site Each camera can be individually controlled from AD1202 front panel switc...

Страница 2: ...is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATI...

Страница 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Страница 4: ......

Страница 5: ...y Reset 6 Camera Selection 6 Camera Programming 6 Preset Scene Programming 7 Video Input Termination 7 Coax Code Selection 7 OPERATION 8 Controlling Camera Site Functions 8 Camera Pan Tilt Control 8 C...

Страница 6: ......

Страница 7: ...mming controls This capability prevents inadvertent changes to camera programming A built in test procedure provides verification of AD1202 front panel controls and indicators FEATURES Individual cont...

Страница 8: ...ideo source is incorrectly unterminated or double terminated coax control will not function properly Looping Video Outputs The AD1202 provides a passive looping output for each camera video input via...

Страница 9: ...TPUT The AD1202 provides an open collector output pulse on pin 15 Alarm Out when an alarm input is received The pulse is held active until the alarm input clears with a minimum of five seconds duratio...

Страница 10: ...ller leave pin 21 open unconnected For operation as a control follower connect pin 21 to ground pin 16 22 or 24 Code Select pin 23 This pin selects the type of coax control code Standard or Enhanced U...

Страница 11: ...camera Each button has two positions fast and slow for use with variable speed pan tilt units When the button is pressed near the center the smaller arrow head the pan tilt action is set to slow spee...

Страница 12: ...mera 2 input 3 for camera 3 and input 4 for camera 4 Each AD1202 input can be programmed to follow any of 16 camera numbers Note To program the AD1202 camera inputs the camera address binary output fr...

Страница 13: ...mera Receiver not in the AD1202 Note The front panel controls must be enabled for preset programming see Programming Blocking page 5 To program and store a preset scene 1 Select the desired camera by...

Страница 14: ...address is provided via the BIN IN pins and the AD1202 automatically selects the camera input programmed for this address The monitor output of the switch should be used to view the selected inputs N...

Страница 15: ...ng to the desired auxiliary number 1 4 The AUX LED turns off Alarm Response There are four alarm inputs on the rear panel EXTERNAL connector see page 3 Each alarm input corresponds to one of the four...

Страница 16: ......

Страница 17: ...Appendix...

Страница 18: ...te simultaneously signifying that the switch closure was recognized by the unit If the LED s flash when a button is pressed one or more buttons may be shorted and the unit is not operating properly 4...

Страница 19: ...Typical System Connections...

Страница 20: ...14 16 18 20 22 24 LOCAL MONITOR AD1641U COAX RECEIVER AD1641U COAX RECEIVER AD1641U COAX RECEIVER NOTE AD1641U Receivers shown for illustration Any AD Receiver with Coax control may be connected in th...

Страница 21: ...IVER AD1641U COAX RECEIVER AD1641M RECEIVER W B S AD1641M RECEIVER W B S PAN TILT NOTE AD1641 Series Receivers shown for illustration Any AD Receiver with Coax or AD Manchester Control Code may be con...

Страница 22: ...de may be connected in this manner If using an AD1645U do not connect pins 2 3 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 HI Z 75 TERM 1 2 3 4 NOTE AD1202 set for Manual Camera Selection See page 3...

Страница 23: ...RECEIVERS AD1641U COAX RECEIVER AD1641U COAX RECEIVER I N AUX 1 4 5 8 120V 60HZ 1 2 3 4 5 6 7 8 B O U T A O U T MD 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 1 2 3 4 HI Z 75 TERM 1 2 3 4 DATA 120V...

Страница 24: ......

Страница 25: ...Index...

Страница 26: ......

Страница 27: ...Control Code Outputs 4 Alarm Inputs 3 Alarm Output 3 Camera Address Output 3 Channel Select Output 3 Code Select Control Pin 4 External Unit Control Pin 4 Factory Reset 6 FEATURES 1 FOCUS Button 5 FR...

Страница 28: ......

Страница 29: ...Camera not terminated properly Check termination of associated camera input pg 7 too dark or bad color Camera iris is not adjusted correctly Adjust camera iris using calibrated monitor Black horizont...

Страница 30: ......

Страница 31: ...tonio Cork Ireland Aguadilla P R 00690 Declares that the product s listed below Name Type MCS Coax Controller Model Number ADS1202X comply with the EMC Standards EN55022 Class B EN50082 1 and also com...

Страница 32: ...rol Code outputs Alarm Inputs Four alarm contact closures Normally Open one input per camera Alarm Output One alarm output TTL open collector pulse Mounting Desktop or Rack mount with AD2117 21 kit Di...

Отзывы: