To program a specific camera select button for a switcher

camera number:

1. Press the front panel PGM button on the AD1202.

The PGM LED illuminates steadily, and the Channel Select
button 1 LED flashes repeatedly.

2. Press the desired AD1202 Channel Select button for the

specific camera input to be programmed. 

The associated Channel Select LED flashes.

3.  Press the desired camera select button on the switcher. The

switcher should indicate the selected camera. (Refer to the
appropriate switcher installation manual for the camera
selection procedures and indicators).

4. Confirm that the AD1202 Channel Select button LED and

the switcher selection indicate the desired choice.  (Either
selection may be changed prior to the next step.)

Note:  Do not program two different AD1202 buttons to the

same switcher camera number. If two buttons are 
programmed for the same camera number the 
AD1202 selects the lower numbered button for that 
camera, and the other button is ignored.

5. Press the front panel SEL button.  This accepts the choices

and programs the AD1202 external camera selection to
respond to the switcher camera selection.

The flashing Channel Select LED advances to the next
sequential Channel Select button to permit further
programming.

6. To program another channel select button repeat the above

steps from step 2.  

Note:  All programming of the select buttons will be held in

non-volatile memory and will not need to be re-
programmed upon a power failure.

Preset Scene Programming

Camera pan/tilt and lens units with preset capability can be
programmed to move automatically to preset scenes using
AD1640/1680 Series Receivers.  A suitably equipped camera
site Receiver can store 72 preset scenes for subsequent recall.
The AD1202 can program and call any of the first four preset
scenes (1 - 4).  Preset scenes are stored at the respective
camera Receiver, not in the AD1202.

Note: The front panel controls must be enabled for preset

programming (see Programming Blocking, page 5).

To program and store a preset scene:

1. Select the desired camera by pressing the corresponding

front panel Channel Select button.

2. Using the AD1202 front panel controls, adjust the camera

pan, tilt, zoom, iris, and focus to obtain the desired scene, as
viewed on the MON video output.

3. Press the front panel PRESET SET button.

The SET LED illuminates.

4. Enter the desired preset number (1 - 4) by pressing the

corresponding Channel Select button.

The Channel Select LED illuminates briefly to confirm the
selection, then both the SET and Channel Select LED’s turn
off, indicating that the preset scene is programmed.

If no Channel Select button is pressed within five seconds
after the SET button is pressed, the function is cancelled
and the SET LED turns off.

Programmed preset scenes 1 - 4 may be called by front panel
commands any time the associated camera is under control of
the AD1202 (see Calling a Preset Scene, page 9).

If Preset Scene 1 is programmed for a camera by the above
AD1202 procedure only
, that preset is automatically called by
the AD1202 when an alarm is received on the Alarm Input
associated with that camera (see Alarm Response, page 10).

Note:  All presets are held in non-volatile memory and will

not need to be reset upon a power failure.

Video Input Termination

The termination of each video input to the AD1202 may be
individually selected as terminated (75 ohms) or unterminated
(Hi-Z) via a rear panel DIP switch, labeled TERM (see Figure
6).  Four separate switches are provided, labeled 1 to 4, one for
each corresponding video input channel.  The factory default
setting of all inputs is Terminated, 75 ohms.

To change the termination of any video input, push the
associated slide switch (switch 1 for input channel 1, etc.) to
the appropriate position:  up for terminated in 75 ohms, or
down for unterminated at Hi-Z.

7

AD1202

SETUP

HI-Z

TERM

1

2

3

4

75 ½

Figure 6 - AD1202 Rear Panel Termination DIP Switch

Содержание AD1202

Страница 1: ...Controller The AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site Each camera can be individually controlled from AD1202 front panel switc...

Страница 2: ...is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATI...

Страница 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Страница 4: ......

Страница 5: ...y Reset 6 Camera Selection 6 Camera Programming 6 Preset Scene Programming 7 Video Input Termination 7 Coax Code Selection 7 OPERATION 8 Controlling Camera Site Functions 8 Camera Pan Tilt Control 8 C...

Страница 6: ......

Страница 7: ...mming controls This capability prevents inadvertent changes to camera programming A built in test procedure provides verification of AD1202 front panel controls and indicators FEATURES Individual cont...

Страница 8: ...ideo source is incorrectly unterminated or double terminated coax control will not function properly Looping Video Outputs The AD1202 provides a passive looping output for each camera video input via...

Страница 9: ...TPUT The AD1202 provides an open collector output pulse on pin 15 Alarm Out when an alarm input is received The pulse is held active until the alarm input clears with a minimum of five seconds duratio...

Страница 10: ...ller leave pin 21 open unconnected For operation as a control follower connect pin 21 to ground pin 16 22 or 24 Code Select pin 23 This pin selects the type of coax control code Standard or Enhanced U...

Страница 11: ...camera Each button has two positions fast and slow for use with variable speed pan tilt units When the button is pressed near the center the smaller arrow head the pan tilt action is set to slow spee...

Страница 12: ...mera 2 input 3 for camera 3 and input 4 for camera 4 Each AD1202 input can be programmed to follow any of 16 camera numbers Note To program the AD1202 camera inputs the camera address binary output fr...

Страница 13: ...mera Receiver not in the AD1202 Note The front panel controls must be enabled for preset programming see Programming Blocking page 5 To program and store a preset scene 1 Select the desired camera by...

Страница 14: ...address is provided via the BIN IN pins and the AD1202 automatically selects the camera input programmed for this address The monitor output of the switch should be used to view the selected inputs N...

Страница 15: ...ng to the desired auxiliary number 1 4 The AUX LED turns off Alarm Response There are four alarm inputs on the rear panel EXTERNAL connector see page 3 Each alarm input corresponds to one of the four...

Страница 16: ......

Страница 17: ...Appendix...

Страница 18: ...te simultaneously signifying that the switch closure was recognized by the unit If the LED s flash when a button is pressed one or more buttons may be shorted and the unit is not operating properly 4...

Страница 19: ...Typical System Connections...

Страница 20: ...14 16 18 20 22 24 LOCAL MONITOR AD1641U COAX RECEIVER AD1641U COAX RECEIVER AD1641U COAX RECEIVER NOTE AD1641U Receivers shown for illustration Any AD Receiver with Coax control may be connected in th...

Страница 21: ...IVER AD1641U COAX RECEIVER AD1641M RECEIVER W B S AD1641M RECEIVER W B S PAN TILT NOTE AD1641 Series Receivers shown for illustration Any AD Receiver with Coax or AD Manchester Control Code may be con...

Страница 22: ...de may be connected in this manner If using an AD1645U do not connect pins 2 3 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 HI Z 75 TERM 1 2 3 4 NOTE AD1202 set for Manual Camera Selection See page 3...

Страница 23: ...RECEIVERS AD1641U COAX RECEIVER AD1641U COAX RECEIVER I N AUX 1 4 5 8 120V 60HZ 1 2 3 4 5 6 7 8 B O U T A O U T MD 1 2 3 4 DATA 120V 60Hz MON EXTERNAL 1 2 23 24 1 2 3 4 HI Z 75 TERM 1 2 3 4 DATA 120V...

Страница 24: ......

Страница 25: ...Index...

Страница 26: ......

Страница 27: ...Control Code Outputs 4 Alarm Inputs 3 Alarm Output 3 Camera Address Output 3 Channel Select Output 3 Code Select Control Pin 4 External Unit Control Pin 4 Factory Reset 6 FEATURES 1 FOCUS Button 5 FR...

Страница 28: ......

Страница 29: ...Camera not terminated properly Check termination of associated camera input pg 7 too dark or bad color Camera iris is not adjusted correctly Adjust camera iris using calibrated monitor Black horizont...

Страница 30: ......