![American Dynamics 1476-C Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/american-dynamics/1476-c/1476-c_installation-and-operating-instructions-manual_2924331008.webp)
FRONT PANEL CONTROLS
AD1476
Figure 11 - AD 1476 Front Panel
FRONT PANEL CONTROLS
All operator controls for the SuperQuad are located on the front panel, see
Figure 11, above.
ON/OFF Rocker Switch
This switch turns power on and off to the SuperQuad HR. Push 1 for power
ON; a red marker will appear on the top of the switch indicating that power
is applied to the SuperQuad. Push 0 for power off.
SELECT Pushbuttons
1-5, 2-6, 3-7, 4-8
: Each of these pushbuttons calls a fullscreen display of the
corresponding cameras to the CALL Monitor output.
pressed once, calls the lower number cameras ( 1 to 4).
Pressed twice quickly, calls the higher number camera (5 '0 8).
Quad AB:
This button is used to call either Quad A or Quad B to the
QUAD Monitor output, depending on the Quad Display mode selected (see
page 10, Quad Display setup).
if MANUAL is selected as the display mode, to obtain:
Quad A - push the QUAD AB button once.
Quad B - push the QUAD AB button twice, quickly.
DuoQuad (alternating Quad A and Quad B) - hold the QUAD A/B
button for two seconds.
When Quad A is selected the Quad A/B button is illuminated. When
Quad B is selected the Quad A/B button is not illuminated. When in
DuoQuad Mode the button illumination alternates on and off.
If A ONLY or B ONLY is selected as the Quad Display mode, only that
Quad can be called by the Quad A/B button.
FUNCTION Pushbuttons
FREEZE:
Alternate depression of this button freezes the currently
displayed Quad picture on both the CALL and QUAD Monitor
outputs or restores the real-time Quad display. When the display is
frozen, the pushbutton is illuminated and an on-screen display of
the word "FROZEN" alerts the operator that the Quad display is not
updating.
RUN:
Alternate action either starts the RUN sequence on the
CALL Monitor or holds the currently-displayed camera on the
CALL Monitor. The pushbutton is illuminated while sequencing.
When a sequence is running, an "R" is displayed in the second line
of the camera titles. When not sequencing, an "H" is displayed to
signify that the sequence is on hold. Holding the RUN pushbutton
for three seconds calls the Programming Setup Menu (page 8).
ALARMS:
Alternate action either enables or disables alarm
handling. Alarm handling can only be disabled when alarms are not
present. The pushbutton is illuminated when alarms are enabled.
During alarm handling, the ALARM pushbutton serves as an
Acknowledge pushbutton. The button does not function when the
unit is in VCR EXPAND mode.
VCR Pushbuttons
EXPAND
: Alternate action switches the SuperQuad in or out of
the VCR PLAYBACK mode. The pushbutton is illuminated when
in the EXPAND mode.
LOOP:
Pressing this button displays video from the EXPAND
input on the QUAD monitor output. The pushbutton is illuminated
when in the Loop-thru mode.
Note:
If the QUAD output is connected to the VCR input, using the
LOOP feature from the VCR output may cause video instability
with some VCR's.