SYSTEM DESCRIPTION

Figure 1 - AD 1476 SuperQuad HR

SYSTEM DESCRIPTION

The AD1476 SuperQuad HR combines a high-resolution quad
display, a multi-function video switcher, and a VCR quad
playback expander with a microprocessor control unit in a
single rack/tabletop enclosure. The VCR playback functions
provide jitter-free expanded pictures from full frame recorders
and digitally enhanced enlargements from single-field, time-
lapse recorders.

The built-in sequential switcher adds the channel-input number
and a user-entered 8-character camera identification data to
each video input. On-screen menus are provided for setup of all
user-programmable functions. Manual or automatic alarm
callup to the Call output are provided. The SuperQuad also
adds date/time data to the on-screen display and provides
RS232 remote control.

AD1476 FEATURES

• High resolution quad display

• Terminated or looping video inputs

• Automatic sensing of VCR mode provides optimized

playback of Quad recordings  - a Loop-thru mode permits
viewing of VCR output on the Quad

• Password-protected setup program with on-screen menus to

enter all user setups - password can be disabled

 •  Separate Quad and Call outputs

• On-screen displays including camera number and 8

character user-entered data

• User setup of full-screen camera sequences on the Call

output - Quad display may be included

• Manual instant freeze of the Quad display

 •  Full screen manual call-up of cameras or the Quad display

 •  Automatic Alarm Call-up of full-screen display of alarmed
    cameras to the Call output - multiple alarms are sequenced

• Alarm inputs individually definable as Normally-Open,

Normally-Closed, or Disabled

• Alarm Clearance modes selectable:

Instant:

Clears each alarm when its alarm input is
deactivated.

Delay:

Holds each alarm for 20 seconds after the alarm

input is deactivated.

Acknowledge:

 Holds each alarm until manually

acknowledged.

Sequencing of the Quad display with the full-screen displays

of alarmed cameras

• Automatic Freeze of Quad picture at the instant of the first

alarm and display of frozen Quad while the alarm is active

• Vertical sync lock to either Camera 1 or the AC line

• On-screen Date/Time display with US or European date

format and 24-hour time format

• User-programmed data battery-backed up for a minimum of

ten years, including on-screen identification of all inputs,
system arming for alarm operation, and date/time

• Video Loss Detection  - At video loss, the quadrant affected

will be blank and the words "VIDEO LOSS" will blink
adjacent to the camera number

• RS-232 remote control

Содержание 1476-C

Страница 1: ...Model 1476 C SuperQuad HR Installation and Operating Instructions...

Страница 2: ...RS 232 5 Video Inputs 6 Video Outputs 7 Front Panel Controls 8 General Operation 9 Quad Operation 9 SuperQuad Operation 9 Video Loss Detection 9 Alarm Handling 9 VCR Playback 10 Setup Programming 10...

Страница 3: ...l outputs On screen displays including camera number and 8 character user entered data User setup of full screen camera sequences on the Call output Quad display may be included Manual instant freeze...

Страница 4: ...nal jumpers see Figure 2 may need to be reset for specific user requirements These jumpers are factory set for most user needs as indicated below and in Figure 2 Color Filters Jumpers J4 27 The SuperQ...

Страница 5: ...ct rating of this relay is 0 6 Amps 120 VAC or 2 0 Amps 30 VAC RS 232 The SuperQuad HR may be controlled via RS 232 connection from a keyboard terminal or computer Refer to page 13 for control of the...

Страница 6: ...n Quad A video inputs 5 thru 8 are displayed in Quad B Refer to Figure 4 Four 3 position slide switches located on the rear panel one under each pair of BNC connectors configure the input termination...

Страница 7: ...hain is terminated in 75 ohms 5 to 7 Camera Configuration If less than eight video sources are used and you do not wish to have a blank screen in one of the Quads or you wish to see one or more high p...

Страница 8: ...ttons FREEZE Alternate depression of this button freezes the currently displayed Quad picture on both the CALL and QUAD Monitor outputs or restores the real time Quad display When the display is froze...

Страница 9: ...re alarmed The Alarm pushbutton blinks whether or not alarm handling is enabled The Alarm cameras are identified on the screen by an A The QUAD Monitor displays either the programmed Quad Display or a...

Страница 10: ...QUAD output This Loop thru capability provides the user with the ability to view the output from the VCR directly on the Quad monitor for ease of VCR setup Note It the QUAD output is connected to the...

Страница 11: ...amming and the ALARMS pushbutton can always acknowledge an alarm Note The unit must be set to operate the way it is intended before the front panel is disabled Unit ID Establishes the SuperQuad Unit I...

Страница 12: ...all entries are displayed as desired press NEXT to store the entries and advance to the QUAD DISPLAY menu QUAD DISPLAY The Quad Display menu lets you select the desire configuration of the QUAD Monito...

Страница 13: ...rmally Closed X Disabled Alarms from this input ignored Use the arrow pushbuttons to position the cursor at the status to be changed Use the or pushbuttons to change the entry until the desired status...

Страница 14: ...and pushbuttons to change the format DATE AND TIME The date and time values are set as three separate fields in each line month day and year for date our minute and second for time Use the arrow push...

Страница 15: ...disconnect is received KEYBOARD CONTROL The AD1475RT keyboard can control one or more SuperQuads via the RS 232 interface Dedicated buttons are provided on the keyboard for all SuperQuad functions ex...