Electric Models Only
All electrically heated dryers must be connected to the electric
service shown on the dryer’s data label. The connecting
wires must be properly sized to handle the rated current.
Warning (Gas Models Only)
Dryers built for use with a voltage between 200
and 240 must verify the input voltage during
!
TERM
LINE VOLTAGE
50 Hz
60 Hz
HIGH
260
226
283
249
MED
239
208
260
230
LOW
217
189
236
208
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify
exact voltage.
When fuses are used they must be dual element, time delay, current limiting,
class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying
either local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others,
calculate/verify correct breaker size according to appliance amp draw rating
and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
OVEN
kW
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
M31SL
200
1ø
2
12.5
68.4
67.7
90
208
1ø
2
7.9
43.8
—
60
208
1ø
2
13.5
70.7
—
90
230
1ø
2
8.3
—
41.3
60
230
1ø
2
12.4
—
59.1
80
240
1ø
2
9.0
42.7
—
60
240
1ø
2
13.5
61.5
—
80
208
3ø
3
13.5
43.3
—
60
220
3ø
3
11.3
35.3
—
50
230
3ø
3
12.4
—
36.5
50
240
3ø
3
13.5
37.7
—
50
380
3ø
4
11.3
22.8
22.6
40
400
3ø
4
12.4
—
23.1
40
416
3ø
4
13.5
—
23.7
40
M50SL
200
1ø
2
14.8
82.1
—
110
208
1ø
2
16.0
85.1
—
110
220
1ø
2
13.4
68.8
69.4
90
230
1ø
2
14.7
—
72.3
100
240
1ø
2
16.0
74.2
75.1
100
200
3ø
3
14.8
—
51.0
70
208
3ø
3
16.0
52.6
—
70
220
3ø
3
13.4
43.0
43.6
60
230
3ø
3
14.7
—
45.3
60
240
3ø
3
16.0
46.0
—
60
380
3ø
4
13.4
28.0
28.6
40
400
3ø
4
14.8
—
29.8
40
416
3ø
4
16.0
—
30.7
40
M50SL Dual Voltage 480 / 120
120
1ø
2
0.0
13.2
—
15
480
3ø
3
16.0
19.2
—
25
M50SL Dual Voltage 480 / 240
240
1ø
2
0.0
6.5
—
15
480
3ø
3
16.0
19.2
—
25
M50SL Dual Voltage 600 / 120
120
1ø
2
0.0
13.2
—
15
600
3ø
3
16.0
15.4
—
20
M50SL Dual Voltage 600 / 240
240
1ø
2
0.0
6.5
—
15
600
3ø
3
16.0
15.4
—
20
M75SL
200
1ø
2
20.3
109.8
—
150
208
1ø
2
22.0
113.9
—
150
220
1ø
2
18.5
91.7
92.3
125
230
1ø
2
20.3
—
96.3
125
240
1ø
2
22.0
99.2
—
125
208
3ø
3
22.0
69.2
—
90
220
3ø
3
18.5
56.2
56.8
80
230
3ø
3
20.3
—
59.1
80
240
3ø
3
22.0
60.4
—
80
380
3ø
4
18.5
35.6
—
45
380
3ø
4
18.5
—
36.2
50
400
3ø
4
20.3
—
37.8
50
416
3ø
4
22.0
—
39.1
50
6/4/08
installation. If the nominal voltage
is outside of the medium
tolerances shown on the diagram
below, adjust the autotransformer,
located near the burner assembly.
To adjust the autotransformer
wiring, place the red wire on the
appropriate tap (HIGH, MED,
LOW) of the autotransformer. For
additional wiring details, refer to the electrical diagram
located on the inside of the control panel.
Electrical Service Specifications
Gas and Steam Models Only
6/4/08
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify
exact voltage.
When fuses are used they must be dual element, time delay, current limiting,
class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying
either local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according to appliance amp
draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
M31SL Gas
120
1ø
2
10.3
—
15
200
1ø
2
8.7
8.8
15
208
1ø
2
8.4
—
15
220
1ø
2
8.1
8.1
15
230
1ø
2
—
7.4
15
240
1ø
2
7.7
7.0
15
M31SL Steam
120
1ø
2
9.3
—
15
208
1ø
2
6.2
6.0
15
220
1ø
2
5.6
5.5
15
230
1ø
2
—
5.4
15
240
1ø
2
5.1
—
15
M50SL Gas
120
1ø
2
15.6
—
20
200
1ø
2
10.5
—
20
208
1ø
2
10.5
—
20
220
1ø
2
10.0
10.7
20
230
1ø
2
—
10.8
20
240
1ø
2
9.7
—
20
M50SL Steam
120
1ø
2
14.4
—
20
200
1ø
2
8.2
—
20
208
1ø
2
8.2
—
20
220
1ø
2
7.8
8.4
20
230
1ø
2
—
8.5
20
240
1ø
2
7.6
—
20
M75SL Gas
120
1ø
2
15.6
—
20
200
1ø
2
10.5
—
20
208
1ø
2
10.5
—
20
220
1ø
2
10.0
10.7
20
230
1ø
2
—
10.8
20
240
1ø
2
9.7
—
20
M75SL Steam
120
1ø
2
14.4
—
20
200
1ø
2
8.2
—
20
208
1ø
2
8.2
—
20
220
1ø
2
7.8
8.4
20
230
1ø
2
—
8.5
20
240
1ø
2
7.6
—
20