24

American Dryer Corp.

113431 - 10

!

!

!

!

!

!

Steam Requirements – High Pressure

Shaded areas are stated in metric equivalents

* The minimum operating pressure for optimum results is 100 psig (689.47

kPa).

Installation Instructions

To ensure an adequate supply of steam is provided, be sure
that the steam supply lines and steam return lines are sized
and laid out as stipulated in this manual.  Inadequate steam
supply lines and steam return lines or improper steam
plumbing will result in poor performance and can cause
component failure.  Clean, dry steam must be provided to the
dryer.

Important

Steam coil failure due to water hammer by wet
steam will void the warranty.

The presence of condensate in the steam supply line will
cause water hammer and subsequent heat exchanger
(steam coil) failure.  The steam supply connection into the
main supply line must be made with a minimum 10-inch
(25.4 cm) riser.  This will prevent any condensate from draining
towards the dryer.
The steam supply line to the dryer must include a 12-inch
(30.48 cm) riser along with a drip trap and check valve.  This
will prevent any condensate from entering the steam coil.
Flexible hoses or couplings must be used.  The dryer vibrates
slightly when it runs and this will cause the steam coil
connections to crack if they are hard piped to the supply and
return mains.
Shutoff valves for each dryer should be installed in the supply
line, return line, and drip trap return line.  This will allow the
dryer to be isolated from the supply main and the return main
if the dryer needs maintenance work.
Install an inverted bucket steam trap and check valve at least
12-inches (30.48 cm) below the steam coil as close to the
coil as possible.  A trap with a minimum capacity of 100 lb
(45.35 kg) of condensate per hour at 125 psi (8.62 bar) is
needed for each unit.  (Based on 2 times the steam
consumption per hour.)
The supply line and the return line should be insulated.  This
will save energy and provide for the safety of the operator and
maintenance personnel.
Water pockets in the supply line, caused by low points, will
provide wet steam to the coil possibly causing steam coil
damage.  All horizontal runs of steam supply piping should
be pitched 1/4-inch (6.35 mm) for every 1 foot (0.31 meters)
back towards the steam supply header causing the
condensate in the line to drain to the header.  Install a bypass
trap in any low point to eliminate wet steam.

Important

Flexible hoses/couplings must be used.  Coil
failure due to hard plumbing connections will void

the warranty.

Operating Steam Pressure

Model

 Maximum

Heat Input

(Normal Load)

Consumption (Approx.)

 @ 125 psi (8.6 bar)

Inlet /

Return

M31SL

150 psig*

1.0 MPa

1.75

 

Bhp

63 lb/hr

28.58 kg/hr

1/2” / 1/2”

M50SL

150 psig*

1.0 MPa

3.75 Bhp

127.5 lb/hr

57.83 kg/hr

3/4” / 3/4”

M75SL

150 psig*

1.0 MPa

4 Bhp

136 lb/hr

61.69 kg/hr

3/4” / 3/4”

Water Information _____________________

Before You Start

Check Local Codes and Permits

Call your local water company or the proper municipal
authority for information regarding local codes.

Important

It is your responsibility to have all plumbing
connections made by a qualified professional to

ensure that the plumbing installation is adequate and
conforms to local, state, and federal regulations or codes.
It is the installer’s or owner’s responsibility to see that the
required water pressure, pipe size, or connections are
provided.  The manufacturer assumes no responsibility if
the fire suppression system is not connected, installed, or
maintained properly.

Installation
Water Supply

The fire suppression system must be supplied with a
minimum water pipe size of 1/2-inch (12.7 mm) and be
provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of
pressure.
If the rear area of the dryer or the water supply is located in an
area where it will be exposed to cold/freezing temperatures,
provisions must be made to protect these water lines from
freezing.

Warning

If the water in the supply line or water solenoid
valve freezes, the fire suppression system will be

inoperative!!

Water Connections

The water connection is made to the 3/4”-11.5 NH hose
adaptor, which is shipped in the tumbler and must be installed
to the 1/2” N.P.T. water connection, located at the upper rear
of the dryer.  A flexible supply line/coupling must be used in
an effort to avoid damaging the electric water solenoid valve.

Note

The 3/4”-11.5 NH is a standard hose coupling
screw thread.  It is not to be confused with 3/4”

N.P.T.  The sealing of an NH connection is made with a
washer opposed to the mating threads of an N.P.T.
assembly.  The 2 thread designs are not compatible.

It is recommended that a filter or strainer be installed in the
water supply line.

Important

Flexible supply line/coupling must be used.
Solenoid valve failure due to hard plumbing

connections will void warranty.
The dryer is to be connected to the water mains using a
new hose set and the old hose set should not be reused.

Содержание M31SL

Страница 1: ...les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils Ne touchez à aucu...

Страница 2: ..._________________________________________________________________ SERIAL NUMBER S ______________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ Replacement parts can b...

Страница 3: ...included with the dryer Before installation check that the local distribution conditions nature of gas and pressure and adjustment of the appliances are compatible CAUTION Dryer s should never be left unattended while in operation When discarding or storing your old clothes dryer remove the door Lorsque vous entreposez ou mettez votre sécheuse au rebut enlevez en la porte Caution Label all wires p...

Страница 4: ...s that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be established for the inspection and cleaning of lint in the burner area exhaust ductwork and area around the back of the dryer The frequency of inspection and cleaning can best be determined from experience at eac...

Страница 5: ..._____ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ ______________________...

Страница 6: ...Australia Only VOLTAGE AVAILABLE 200 416V 1 3ø 2 3 4w 50 60 Hz APPROXIMATE NET WEIGHT 285 lb 129 27 kg APPROXIMATE SHIPPING WEIGHT 310 lb 140 61 kg AIRFLOW 60 Hz 360 cfm 10 19 cmm 50 Hz 300 cfm 8 49 cmm EXHAUST CONNECTION DIAMETER 6 15 24 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 7 9 26 962 6 794 8 3 28 327 7 138 9 0 30 716 7 740 11 3 38 566 9 719 12 4 ...

Страница 7: ...113431 10 www amdry com 7 M31SL Specifications _______________________________________________________________ ...

Страница 8: ...mm HEAT INPUT 90 000 Btu hr 22 680 kcal hr EXHAUST CONNECTION DIAMETER 8 20 32 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION 1 2 M N P T 1 2 F B S P T CE and Australia Only VOLTAGE AVAILABLE 120 600V 1 3ø 2 3 4w 50 60 Hz APPROXIMATE NET WEIGHT 545 lb 247 21 kg APPROXIMATE SHIPPING WEIGHT 565 lb 256 28 kg AIRFLOW 60 Hz 525 cfm 14 87 cmm 50 Hz 437 cfm 12 37 cmm EXH...

Страница 9: ...113431 10 www amdry com 9 M50SL Specifications _______________________________________________________________ ...

Страница 10: ...N 1 2 M N P T 1 2 F B S P T CE and Australia Only VOLTAGE AVAILABLE 200 416V 1 3ø 2 3 4w 50 60 Hz APPROXIMATE NET WEIGHT 600 lb 272 16 kg APPROXIMATE SHIPPING WEIGHT 620 lb 281 23 kg AIRFLOW 60 Hz 560 cfm 15 86 cmm 50 Hz 466 cfm 13 19 cmm EXHAUST CONNECTION DIAMETER 8 20 32 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 18 5 63 105 15 902 20 3 69 000 17 000 ...

Страница 11: ...113431 10 www amdry com 11 M75SL Specifications _______________________________________________________________ ...

Страница 12: ...National Electrical Code or in Canada the installation must conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing or Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION for Electrical Connections Location Requirements _______________ Before installing the dryer be sure the l...

Страница 13: ...commended that exhaust or booster fans not be used in the exhaust ductwork system A 6 inches 15 24 cm B 24 inches 60 96 cm EXAMPLE For M50SL 2 unrestricted openings measuring 6 inches by 24 inches 15 24 cm by 60 96 cm are acceptable If a closet door is installed unobstructed air openings are required The air openings shall be located 3 inches 7 62 cm from the lower opening above floor level and up...

Страница 14: ...r the appliance category in accordance with national installation regulations of the country of destination Outside Ductwork Protection To protect the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be installed where the exhaust exits the building If the ductwork travels vertically up through the roof it should be protected from the weather by using a 180 t...

Страница 15: ...not use aluminum wire which could cause a fire hazard The copper conductor wire cable must be of proper ampacity and insulation in accordance with electric codes for making all service connections Note The use of aluminum wire will void the warranty An individual ground circuit must be provided to each dryer do not daisy chain Component failure due to improper voltage application will void the war...

Страница 16: ...oltage 600 240 240 1ø 2 0 0 6 5 15 600 3ø 3 16 0 15 4 20 M75SL 200 1ø 2 20 3 109 8 150 208 1ø 2 22 0 113 9 150 220 1ø 2 18 5 91 7 92 3 125 230 1ø 2 20 3 96 3 125 240 1ø 2 22 0 99 2 125 208 3ø 3 22 0 69 2 90 220 3ø 3 18 5 56 2 56 8 80 230 3ø 3 20 3 59 1 80 240 3ø 3 22 0 60 4 80 380 3ø 4 18 5 35 6 45 380 3ø 4 18 5 36 2 50 400 3ø 4 20 3 37 8 50 416 3ø 4 22 0 39 1 50 6 4 08 installation If the nominal...

Страница 17: ... wire size must conform to rating of dryer or the dryer can be hard wired directly to the service breaker panel In both cases a strain relief must be installed where the wiring enters the dryer For CE Models Only The means for disconnection from the supply must be incorporated into wiring having a minimum contact separation of 3 0 mm in all poles Single Phase 1ø Wiring Connections Hookup The elect...

Страница 18: ...g its individual manual shutoff valve during any pressure test of the gas supply system at test pressures equal to or less than 1 2 psig 3 5 kPa for non CE dryers or 50 mb for CE dryers Warning Fire or explosion could result due to failure of isolating or disconnecting the gas supply as noted Note Undersized gas piping will result in ignition problems slow drying increased use of energy and can cr...

Страница 19: ... 2 6 9 Natural I2L 830 20 35 110 000 32 24 3 753 M3 H 22 3 988 2 9 5 Natural I2ELL 830 15 30 110 000 32 24 3 753 M3 H 22 3 988 2 9 5 Natural I2E 1 000 20 110 000 32 24 3 115 M3 H 31 3 048 2 830 25 110 000 32 24 3 753 M3 H 31 3 048 2 Butane I3 3 175 28 30 110 000 32 24 2 324 kg H 48 1 930 2 Propane I3 2 500 37 110 000 32 24 2 324 kg H 48 1 930 2 Butane I3B P 3 175 28 30 50 110 000 32 24 2 324 kg H ...

Страница 20: ... of dryers An in line pressure regulator must be installed in the gas supply line header if the natural gas pressure exceeds 13 0 in wc 32 34 mb pressure A plugged tap accessible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers Important Pipe joint compounds that resist the action of natural L P and butane gases must be used Test all ...

Страница 21: ...onnect the union 3 electrical plugs and the gas train mounting screws from the burner Carefully slide the gas train out of the gas train enclosure The carbon ignitor located at the far end of the gas train is very fragile Remove 2 burner tube mounting screws and remove burner tube in order to gain access to the orifice Using a 3 8 wrench or socket remove the existing orifice and replace it with an...

Страница 22: ...der vent cap Remove spring under screw and replace with spring from kit ADC P N 140415 Replace regulator adjustment screw Install the gas train back into the dryer gas train enclosure Be sure the tab at the rear of the gas train engages into the mounting slot Connect the union and the 3 electrical plugs Open all shutoff valves reconnect electrical power to the dryer and test for leaks Operate the ...

Страница 23: ...r Tighten screw inside the pressure tap or install plug Turn gas cock to ON position and check for leaks with soap solution with main burner ON Steam Information ____________________ It is your responsibility to have all plumbing connections made by a qualified professional to ensure that the steam plumbing installation is adequate and conforms with local state and country regulations or codes Car...

Страница 24: ...stall a bypass trap in any low point to eliminate wet steam Important Flexible hoses couplings must be used Coil failure due to hard plumbing connections will void the warranty Operating Steam Pressure Model Maximum Heat Input Normal Load Consumption Approx 125 psi 8 6 bar Inlet Return M31SL 150 psig 1 0 MPa 1 75 Bhp 63 lb hr 28 58 kg hr 1 2 1 2 M50SL 150 psig 1 0 MPa 3 75 Bhp 127 5 lb hr 57 83 kg...

Страница 25: ...Check that the vent is connected to the dryer and is exhausted to the outdoors STEAM MODELS Check to ensure all steam shutoff valves are open Preoperational Test ___________________ All dryers are thoroughly tested and inspected before leaving the factory However a preoperational test should be performed before the dryer is publicly used It is possible that adjustments have changed in transit or d...

Страница 26: ...ill start and the L C D will display the Dry Cycle selected and the remaining time The dryer will continue through the drying and cooling cycles until the vended time has expired Note To stop the dryer open main door Continuation of the cycle will resume only after the door has been closed and any one of the 3 temperature selections is pressed Non Coin Models Microprocessor Controller Computer The...

Страница 27: ...factory for warranty information be sure to have the dryer s model number and serial number available so that your inquiry can be handled in an expeditious manner Returning Warranty Parts All dryer or parts warranty claims or inquiries should be addressed to the Warranty Parts Department To expedite processing the following procedures must be followed No parts are to be returned without prior writ...

Страница 28: ...an lint accumulation from lint chamber thermostat and microprocessor temperature sensor area Warning To avoid the hazard of electrical shock discontinue electrical supply to the dryer Steam Dryers Clean the steam coil fins It is suggested that compressed air and a vacuum cleaner with brush attachment be used Warning When cleaning steam coil fins be careful not to bend the fins If fins are bent str...

Страница 29: ...tric or steam 2 Serial Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or L P gas electric or steam 4 Heat Input For Gas Dryers This describes the heat input in British thermal units per hour Btu hr or kilowatts kW 5 Orifice Size For Gas Dryers Gives the number drill size u...

Страница 30: ...ADC Part No 113431 10 06 04 08 10 ...

Отзывы: