40
S
AFETY
D
EVICES
L
OCATION
F
UNCTION
C
OMPUTER
D
ISPLAY
M
ESSAGE
R
ESULT OF
T
RIPPING
L
OAD
D
OOR
S
WITCH
L
EFT
S
IDE
O
F
L
OAD
D
OOR
I
NSURES DRYER LOAD
DOOR ARE CLOSED
"DOOR
OPEN"
D
RYER WILL NOT RUN
U
NLOAD DOOR
SWITCH
(T
WO DOOR
UNIT ONLY
)
R
IGHT SIDE OF
UNLOAD DOOR
I
NSURES DRYER
UNLOAD DOORS ARE
CLOSED
"DOOR
OPEN"
D
RYER WILL NOT RUN
T
ILTING
S
WITCHES
T
OP LEFT SIDE OF
BASE MODULE
I
NSURES DRYER IS
LEVEL
"LEVEL
FAULT"
D
RYER WILL NOT RUN
D
RUM
R
OTATION
S
ENSOR
L
EFT SIDE OF
TUMBLER SECTION
I
NSURES TUMBLER IS
ROTATING
"DRUM
FAULT"
S
TOPS HEAT ONLY
L
INT
C
HAMBER AIR
PRESSURE SWITCH
C
ENTER OF HEAT
C ONSOLE
I
NSURES PROPER AIR
FLOW THROUGH DRYER
"AIRFLOW
FAULT"
S
TOPS HEAT ONLY
B
URNER
F
AN
A
IR
F
LOW
S
WITCH
(G
AS
D
RYERS
O
NLY
)
C
ENTER OF HEAT
C ONSOLE
I
NSURES PROPER
CAOMBUSTION AIR
FLOW INTO THE
BURNER BOX
"HEATER
FAULT"
S
TOPS HEAT ONLY
H
I
/L
O
G
AS
P
RESSURE
S
WITCH
(G
AS
D
RYERS
O
NLY
)
L
OWER LEFT OF HEAT
CONSOLE SECTION
I
NSURES PROPER GAS
SUPPLY PRESSURE FOR
ADEQUATE IGNITION
"GAS
SUPPLY
FAULT"
S
TOPS HEAT ONLY
H
EAT
R
ECLAIMER
D
AMPER
S
WITCH
R
IGHT SIDE OF HEAT
C ONSOLE
I
NSURES THAT THE
HEAT RECLAIMER IS
EITHER OPENED OR
CLOSED
I
NPUT
LED
#13
OF
THE
PLC
IS OFF
N
ONE
H
EAT
C
ONSOLE
D
OOR
A
CC ESS
D
OOR
S
WITCH
I
NSIDE
H
EAT
C
ONSOLE
I
NSURES THAT ACCESS
DOORS ARE CLOSED
"DOOR
OPEN"
D
RYER WILL NOT RUN
E
XHAUST
A
IR
T
EMP
C
ONTROL
S
ENSOR
I
NSIDE
B
URNER
SECTION DUCT
M
ONITORS TUMBLER
EXHAUST AIR TEMP
"EXHAUST
DSFL"
S
TOPS HEAT ONLY
E
XHAUST
A
IR
H
I
T
EMP
C
ONTROL
S
ENSOR
I
NSIDE EXHAUST DUCT
M
ONITORS TUMBLER
EXHAUST AND AIR TEMP
"HI-TEMP
FAULT"
S
TOPS HEAT ONLY
I
NTAKE
A
IR
T
EMP
C
ONTROL
S
ENSOR
(
OPTIONAL
)
T
OP RIGHT OF
TUMBLER SECTION
M
ONITORS TUMBLER
AIR INTAKE TEMP
"INTAKE
DSFL"
S
TOPS HEAT ONLY
I
NTAKE
A
IR
T
EMP
C
ONTROL
S
ENSOR
T
OP RIGHT OF
TUMBLER SECTION
M
ONITORS TUMBLER
AIR INTAKE TEMP
"HI-TEMP
FAULT"
S
TOPS HEAT ONLY
B
URNER
H
I
-L
IMIT
S
AFETY
S
ENSOR
T
OP OF BURNER
SECTION
M
ONITORS AIR TEMP
ABOVE THE BURNER
BOX
"HI-TEMP
FAULT"
S
TOPS HEAT ONLY
S
PRINKLER
C
ONTROL
S
AFETY
S
ENSOR
T
OP RIGHT OF
TUMBLER SECTION
O
PEN SPRINKLER
SYSTEM WATER VALVE
ON HI
-
TEMP CONDITION
O
RANGE SPRINKLER
PILOT LIGHT COMES
ON
.
A
LARM HORN
SOUNDS
O
PENS THE SPRINKLER
WATER VALVE AND
POWER DOWN THE
WHOLE DRYER
L
INT
D
RAWER
S
WITCHES
A
BOVE LINT DRAWER
HANDLES
D
ISABLES MACHINE
WHEN DRAWERS ARE
OPEN OR IF DRAWERS
HAVE NOT BEEN
CLEANED IN LAST FIVE
LOADS
.
L
INT
D
RAWER
D
RYER WILL NOT RUN