14
2. Electric
a. Tumbler (Basket) Motors
The disconnects for the two (2) tumbler (basket) motors are located in the lower heat console. The right
drum (tumbler/basket) motor disconnect is located in the lower heat console on the upper shelf towards
the left. The left drum (tumbler/basket) motor disconnect is located in the base of the lower heat console
to the right. On both cables the mechanical connections
should be
made to the respective junction box.
Remove the two (2) screws that hold down the cover of each junction box. Insert cable end in the junction
box and fasten with lock nut. Then begin to connect the four (4) wires with the same color tape identifiers
together with the four (4) wires already in the junction box. Make these connections with wire nuts and
PVC electrical tape. Replace the cover and the cover (2) screws that hold down the cover to the junction
box.
b. Temperature Probe, Base, and Tumbler (Basket) Disconnects
The disconnects are located in the lower heat console. The temperature probe disconnect is located on
the upper shelf towards the left. The base disconnect and the tumbler (basket) disconnect are located on
the base towards the right. Check identifying tapes to ensure proper assignments of connectors to the
proper base. Check for proper keying and connect disconnect to the proper base. Engage hold downs on
base and verify that the clamps are properly locked.