![American Dryer Corp. AD-758DV Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/american-dryer-corp/ad-758dv/ad-758dv_installation-manual_2923423051.webp)
47
1. Fault in main door switch circuit.
2. Blown fuse (2-amp very fast acting fuse [if applicable]).
3. Failed arc suppressor (A.S.) board (for Reversing Models Only).
4. Failed microprocessor controller (computer).
5. Failed 24 VAC transformer.
H. Both drive motor and blower motor run a few minutes and then stop...microprocessor controller
(computer) display continues to read time or percent of extraction and ALL indicator dots are
off...
1. Fault in main door switch circuit...
a. Failed main door switch.
b. Main door switch is out of adjustment.
c. Loose connection in door switch circuit.
I. Microprocessor controller (computer) display reads dSFL...
1. Fault in microprocessor heat sensing circuit...
a. Failed microprocessor temperature sensor.
b. Failed microprocessor controller (computer).
c. Broken wire or connection somewhere between the microprocessor controller (computer) and the
microprocessor temperature sensor.
J. Microprocessor controller (computer) display reads door...
1. Fault (open circuit) in door switch circuit...
a. Failed main door switch.
b. Broken connection/wire in main door circuit.
2. Failed 24 VAC transformer.
K. Microprocessor controller (computer) will not accept any keyboard (touch pad) entries, i.e.,
light emitting diode (L.E.D.) display reads FILL and when keyboard (touch pad) entries are
selected, the L.E.D. display continues to read FILL...
1. Failed keyboard (touch pad) label assembly.
2. Failed microprocessor controller (computer).