25
IMPORTANT:
Figures shown are for non-reversing models ONLY. For reversing models, contact
the factory.
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the upper left side panel area behind the top control (access) door. In the
case of 208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label
exactly
.
IMPORTANT:
The wire size
must be
properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE
NOT
THE
SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
ADG-758DV (GAS)
ADS-758DV
(STEAM )
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES:
A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5
ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical
Codes t listed appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
Dual Element
Time Delay
CIRCUIT
BREAKER
60 Hz
50 Hz
120
1ø
2
12
---
*
20
20
208
1ø
2
7.1
---
*
15
15
240
1ø
2
6.5
---
*
15
15
208
3ø
3
4.7
---
*
15
15
240
3ø
3
4.9
5.5
*
15
15
380/400
3ø
3/4
---
2.9
*
15
15
416
3ø
3/4
---
3.1
*
15
15
460/480
3ø
3/4
2.8
---
*
15
15
*AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.