2. Technical Gas Data
a. Gas Specifications
b. Gas Connections
Inlet connection ------------------- 3/4 N.P.T.
Inlet supply size------------------- 3/4 N.P.T. (minimum)
Btu/hr input (per dryer)---------- 175,000 (44,100 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryers gas valves internal regulator. Incoming supply pressure
must be
consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valves internal pressure regulator blocked open so
that the gas pressure
must be
regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap
must be
a consistent 10.5 inches (26.1 mb) water column. There is no regulator
or regulation provided in an L.P. dryer. The water column pressure
must be
regulated at the source
(L.P. tank) or an external regulator
must be
added to each dryer.
* Drill Material Size (D.M.S.) equivalents are as follows:
Natural Gas......................... #30 = 0.1285 (3.2639 mm).
Liquid Propane Gas.............#49 = 0.0730 (1.8542 mm).
TYPE OF GAS
NATURAL
LIQUID PROPANE
Manifold Pressure*
3.5 inches W.C.
8.7 mb
10.5 inches W.C.
26.1 mb
In-Line Pressure
6.0 - 12.0 inches W.C.
14.92 - 29.9 mb
11.0 inches W.C.
27.4 mb
Shaded areas are stated in metric equivalents
* Measured at outlet side of gas valve pressure tap when gas valve is on.
TYPE OF GAS
L.P.
Conversion Kit
Part Number
ADC
MODEL
NUMBER
BTU
Per Hour
Rating
kcal/hr
Rating
Natural
Liquid Propane
Qty. D.M.S.*
Part
Number
Qty. D.M.S.*
Part
Number
AD-758DV
175,000
44,100
4
#30
140819
4
#49
140803
882230
Shaded area is stated in metric equivalent