5. Make a complete operational check of
ALL
operating controls.
NOTE
: If computer program changes are required, refer to the computer programming section of the
manual supplied with the dryer.
6. The dryer
should be
operated through one (1) complete cycle to assure that no further adjustments are
necessary and that
ALL
components are functioning properly.
BASKET COATING
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth
material with a solution of water and non-flammable mild detergent and tumbling them in the basket (tumbler)
to remove this coating.
7. Check the electric service phase sequence (3-phase [3ø] models only). While the dryer is operating, check to
see if the blower wheel (impeller/fan) is rotating in the proper direction. Looking from the front, the blower
(impellor/fan) wheel should spin in the clockwise (CW) direction. If it is, the phasing is correct. If the phasing
is incorrect, reverse two (2) of the three (3) leads at connections L1, L2, L3 of the power supply to the dryer.
IMPORTANT
: If the blower wheel (impellor/fan) is rotating in the wrong direction, this will not only
drastically reduce drying efficiency, but it can also cause premature component failure.
K. PREOPERATIONAL INSTRUCTIONS
C
OIN
M
ODELS
1. Automatic Mode (Microprocessor [Computer] Models)
a. When turning on power or when no cycle is in progress, the L.E.D. (light emitting diode) display will read
"FILL" and/or "Amount to Start."
b. Insert coin(s).
Once correct "Amount to Start" has been inserted the L.E.D. (light emitting diode) display will read
"PUSH."
c. Select temperature by pushing "HI TEMP," "LO TEMP," or "PERM PRESS." The dryer will start, the
L.E.D. (light emitting diode) display will read the temperature cycle selected, and the drying time portion
of the L.E.D. (light emitting diode) display will read "00" and count upward as time elapses.
IMPORTANT
: If the door is opened during a cycle, both the heat and motor will stop. However, the
microprocessor controller (computer) will continue to count downward in time.
Continuation of the cycle will resume only after the door has been closed and any
other of the three (3) temperature selection buttons is again depressed.
d. Once the preprogrammed dryness level and cool down period have been reached, or the maximum
automatic time has expired, the tone (buzzer) will sound for five (5) seconds, and the L.E.D. (light emitting
diode) display will read "donE", at which time the dryer will shut off.