23
IMPORTANT
: Figures shown are for non-reversing models ONLY. For reversing models contact the
factory.
IMPORTANT
: The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the back side of the upper or top control door. In the case of 208 VAC or
230/240 VAC, the supply voltage
must match
the electric service specifications of
the data label
exactly
.
IMPORTANT
: The wire size
must be
properly sized to handle the related current.
WARNING
:
208 VAC and 230/240 VAC ARE NOT THE SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE
:
ADC
reserves the right to make changes in specifications at any time, without notice or
obligation.
EURO-24 (G
AS
)
EURO-24
(S
TEAM
)
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT
: 208 VAC and 230/240 VAC
ARE NOT THE SAME
.
When ordering, specify
NOTES
:
A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5
ONLY
.
B. Circuit breakers are thermal magnetic (industrial) type
ONLY
. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers
must be
3-pole type.
VOLTAGE
PHASE
SERVICE
AMP DRAW
BREAKER
60 Hz
50 Hz
120
1ø
2
12
--
25
208
1ø
2
7
--
15
240
1ø
2
7
5
15
208
3ø
3/4
3
--
15
240
3ø
3
3
4
15
380-400
3ø
3/4
--
2
15
416
3ø
3/4
--
2
15
460/480
3ø
3/4
2
--
15