6. Steam Damper Air Piston (Flow Control) Operation Adjustment
Although the steam damper operation was tested and adjusted prior to shipping at 80 psi (5.51 bar), steam
damper operation
must be
checked before the dryer is put into operation (refer to the
illustration above
for correct steam damper operation). If steam damper adjustment is necessary, locate the flow control
valve and make the necessary adjustments as noted below.