background image

American DJ

®

  -  www.americandj.com  - X-Move LED 25R Instruction Manual Page 6

American DJ

®

  -  www.americandj.com  - X-Move LED 25R Instruction Manual Page 5

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

X-Move LED 25R.The American DJ

®

 X-Move LED

 

25R is available in 

a 120v and 220v version. Because line voltage may vary from venue 

to venue, you should be sure your unit voltage matches the wall outlet 

voltage before attempting to operate you fixture.  Also be sure to only 

use the included I.E.C. power cable supplied with the unit, this cable 

matches the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and Master/Slave Operation): 

The X-Move LED 

25R can be controlled via DMX-512 protocol. The 

X-Move LED 25R is a nine channel DMX unit. The 

DMX address is set electronically using the con-

trols on the front panel of the unit. Your unit and 

your DMX controller require a approved DMX-512 

110 Ohm Data cable for data input and data output 

(Figure 1). We recommend Accu-Cable DMX cables. If you are making 

 X-Move LED 25R                                                       Set Up

Figure 1

your own cables, be sure to use standard 110-120 Ohm shielded cable 

(This cable may be purchased at almost all professional sound and 

lighting stores). Your cables should be made with a male and female 

XLR connector on either end of the cable. Also remember that DMX 

cable must be daisy chained and cannot be split.

 X-Move LED 25R   

 

                                 Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Содержание X-Move LED 25R

Страница 1: ...ligent moving head mini LED fixture The X Move LED 25R can operate as a stand alone fixture or in a Master Slave configuration The X Move LED 25R has three operating modes a sound active show mode DMX...

Страница 2: ...appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance X Move LED 25R Safety Precautions American DJ www americandj...

Страница 3: ...ess is set electronically using the con trols on the front panel of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We...

Страница 4: ...in a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a pr...

Страница 5: ...ement angle left to right to left is 160 Tilt movement angle is 90 Show 4 For fixtures fixed to the ceiling or truss The beam is projected at the audience s direction i e in front of the stage Pan mov...

Страница 6: ...System Menu 2 To activate the Pan inversion tap the UP or DOWN buttons until I is displayed press ENTER to confim To deactivate Pan inversion select No and press Enter I TLT Tilt Inversion 1 Tap the M...

Страница 7: ...er cable runs we suggest a termina tor at the last fixture 2 On the Master unit find your desired show and set that show by pressing the ENTER button 3 On the slave units tap the MENU button until SLN...

Страница 8: ...out Show Mode This mode allows either a single unit or several units linked together to run one of four shows that you choose 1 Tap the MENU button until SHND is displayed and press ENTER 2 Tap the UP...

Страница 9: ...gable gobos When changing the gobos please be very careful Follow the instructions below and see the figure pictures on the next page Caution Never open the unit when in use Always disconnect the main...

Страница 10: ...ld be carried out periodically to optimize light output Cleaning frequency depends on the environ ment in which the fixture operates I e smoke fog residue dust dew In heavy club use we recommend clean...

Страница 11: ...ty of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the sole discretion of American DJ All products covered by this warra...

Страница 12: ...Cycle None DMX 9 DMX Channels Colors 8 White Gobos 6 Spot 23 8mm 0 2mm thickness 19mm viewable Sound Active Yes Working Position Any Safe Secure Position Warranty 3 Year 1095 days Voltage is user sel...

Отзывы: