background image

 Accu Spot 575 

 

 

 

             System Menu

 Accu Spot 575 

 

 

 

             System Menu

3. Tap the UP button until “

SCAN

” is displayed. 

4. Press ENTER to reset the pan/tilt motors, or press MODE/
ESC to cancel and return to the main menu.

COLR

 - When you activate this reset function, the fixture 

will only reset the color wheel motor.

1. Access the main menu.
2. Tap the UP button until “

RESE

” is displayed, press ENTER.

3. Tap the UP button until “

COLR

” is displayed. 

4. Press ENTER to reset the color wheel motor, or press MODE/
ESC to cancel and return to the main menu.

GOBO

 - When you activate this reset function, the fixture 

will only reset the gobo wheel motor.

1. Access the main menu.
2. Tap the UP button until “

RESE

” is displayed, press ENTER.

3. Tap the UP button until “

GOBO

” is displayed. 

4. Press ENTER to reset the gobo wheel motor, or press MODE/
ESC to cancel and return to the main menu.

SHTR

 - When you activate this reset function, the fixture 

will only reset the shutter/dimmer motor.

1. Access the main menu.
2. Tap the UP button until “

RESE

” is displayed, press ENTER.

3. Tap the UP button until “

SHTR

” is displayed. 

4. Press ENTER to reset the shutter/dimmer motor, or press 
MODE/ESC to cancel and return to the main menu.

OTHR

 - When you activate this reset function, the fixture 

will reset all other motors that are not listed in RESET 

menu.

1. Access the main menu.
2. Tap the UP button until “

RESE

” is displayed, press ENTER.

3. Tap the UP button until “

OTHR

” is displayed. 

4. Press ENTER to reset all other motors, or press MODE/ESC 
to cancel and return to the main menu.

TIME  

MAIN MENU -

LIFE

 - With this function you can display the total running 

time of the unit.

1. Access the main menu.
2. Tap the UP button until “

TIME

” is displayed, press ENTER.

3. Tap the UP button until “

LIFE

” is displayed, press ENTER.

4. Press MODE/ESC to return to the main menu.

LAMP

 - With this function you can display the running time 

of the lamp.

1. Access the main menu.
2. Tap the UP button until “

TIME

” is displayed, press ENTER.

3. Tap the UP button until “

LAMP

” is displayed, press ENTER.

4. Press MODE/ESC to return to the main menu.

CLMP

 - With this function you can clear the running time of 

the lamp. Note Very Important: Please clear the lamp time 

every time you replace the lamp.

1. Access the main menu.
2. Tap the UP button until “

TIME

” is displayed, press ENTER.

3. Tap the UP button until “

CLMP

” is displayed, press ENTER.

©

American DJ

®

  -  www.americandj.com  - Accu Spot 575 Instruction Manual Page 22

American DJ

®

  -  www.americandj.com  - Accu Spot 575 Instruction Manual Page 21

Содержание Accu Spot 575

Страница 1: ...able of Contents Unpacking 3 Introduction 3 Customer Support 3 Safety Precautions 4 Handling Precautions 5 Discharge Lamp Warnings 5 Registration 6 Features 6 Mounting 7 Controls and Functions 8 Set U...

Страница 2: ...Accu Spot 575 General Information For Your Own Personal Safety Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit To reduce the risk of electrical sh...

Страница 3: ...shipper at the shippers cost Accu Spot 575 Product Registration American DJ www americandj com Accu Spot 575 Instruction Manual Page 6 To optimize the performance of this product please read these op...

Страница 4: ...e different mounting positions hanging upside down from a ceiling sound mounted or set on a flat level surface To avoid internal damage to the unit never mount the unit on its side as illustrated abov...

Страница 5: ...he chain See Terminator on page 11 10 XLR DMX Input Jack This jack is used to receive an incoming DMX signal or Master Slave signal 11 Fuse Holder This housing stores a 8 amp 4 amp 220v GMA pro tectiv...

Страница 6: ...icandj com Accu Spot 575 Instruction Manual Page 12 Power Supply Before plugging your unit in be sure the source volt age in your area matches the required voltage for your American DJ Accu Spot 575 T...

Страница 7: ...t COLR Reset only motors for colors GOBO Reset only motors for gobo and rotation SHTR Reset only motors for shutter and or dimmer 4 RESE OTHR Reset other motors LIFE 0000 9999 Displays the total fixtu...

Страница 8: ...dress via external controller DLOF Switch lamp on via DMX DLAY Set a delay time for the lamp SPOT This provides a spot beam for better lamp optimization Accu Spot 575 System Menu ADDRESS MENU AOO1 A51...

Страница 9: ...DR is displayed press ENTER 4 Now the display will show A001 Adjust the DMX address by pressing the UP or DOWN buttons 5 Press ENTER to confirm 6 Press the MODE ESC button to return to the main menu W...

Страница 10: ...tion the fixture will only reset the pan tilt motor 1 Access the main menu 2 Tap the UP button until RESE is displayed press ENTER button and test the different channels 4 Press MODE ESC to exit PLAY...

Страница 11: ...cancel and return to the main menu OTHR When you activate this reset function the fixture will reset all other motors that are not listed in RESET menu 1 Access the main menu 2 Tap the UP button unti...

Страница 12: ...icrophone sen sitivity between M 01 M 99 6 Press ENTER to confirm when you have reached your desired microphone sesitivity level 7 Press MODE ESC to return to the main menu Accu Spot 575 System Menu 4...

Страница 13: ...tion or OFF to deactivate this function 5 Press ENTER to confirm 6 Press MODE ESC to return to the main menu SPEC MAIN MENU LAAU With this function the lamp will automatically light when power is appl...

Страница 14: ...was in when you started editing 1 Access the main menu 2 Tap the UP button until SPEC is displayed press ENTER Accu Spot 575 System Menu address First make sure all channels are set to the value of 0...

Страница 15: ...return to the main menu SPEE With this function you can select the movement mode 1 Access the main menu 2 Tap the UP button until SPEC is displayed press ENTER 3 Tap the UP button until SPEE is displ...

Страница 16: ...ENTER to save and press MODE ESC to exit REC With this function you can record the scenes auto matically for the external controller 1 Access the main menu Accu Spot 575 System Menu 2 0 V 9 9 etc 5 Pr...

Страница 17: ...s maximum 9 Once all the channels are completed the display will flash TIME this stands for the time needed to run this scene 10 Press ENTER to edit the time needed the display shows TXXX X stands for...

Страница 18: ...d into the fixture it will stop the procedure and return to the pre vious menu 8 Press MODE ESC to exit the EDIT menu and return to the main menu Accu Spot 575 Editing Program 13 Repeat steps 3 12 to...

Страница 19: ...of the motors an error code will flash in the display in the form of XXer XX will represent a function number For example when the display shows 02Er it means there is some type of error with the chan...

Страница 20: ...I RUN will make the units run through a built in program AUDI will make the units sound active 4 Press UP to select ALON or NAST Which means stand alone or master slave mode 5 Select a mode and press...

Страница 21: ...der housing located on the back of the unit Turn the screwdriver in counter clockwise direction to remove the fuse holder Remove the old fuse and discard it replace the fuse with the same type Insert...

Страница 22: ...4 159 GOBO 3 SHAKE 160 175 GOBO 4 SHAKE 176 191 GOBO 5 SHAKE 192 207 GOBO 6 SHAKE 208 223 GOBO 7 SHAKE 224 255 GOBO WHEEL ROTATION SLOW FAST Accu Spot 575 DMX Traits Channel Value Function 1 0 255 PAN...

Страница 23: ...AL PROGRAMS 0 19 COLOR CHANGE NORMAL 20 39 COLOR CHANGE TO ANY POSITION 40 59 LAMP ON Accu Spot 575 DMX Traits cont Accu Spot 575 DMX Traits cont Channel Value Function 9 ROTATING PRISM PRISM GOBO MAC...

Страница 24: ...with your hand until you come across the gobo you would like to change 4 With your finger push the gobo out towards the front and then slide the gobo up and out of the wheel When doing this you do no...

Страница 25: ...es sory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by American DJ in connection with this product includ ing warranties of mer...

Страница 26: ...afe Secure Position Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Specifications and improvements in the design of this unit and this manual are subj...