WARNING: 

ADC

®

recommends that spare lamps, batteries, and replacement parts always

be available for emergency use.

WARNING: 

The sterilization guidelines included in this instruction booklet are intended as

procedures compatible with specific materials. Sterilization must be performed to approved

hospital protocol. ADC

®

cannot guarantee that any of the recommended methods will guar-

antee sterility. This must be validated by the hospital and/or sterilization equipment manu-

facturer.

WARNING:

Fiberoptic handles may be used with ALL fiberoptic blades (reusable or dis-

posable) that conform to the ISO 7376 standards. Standard handles may be used with any

standard blades that conform to the ISO 7376 standards. Standard and fiberoptic blades and

handles are NOT interchangeable.

Operation of all Laryngoscope Models

To Activate:

Attach selected blade onto handle by hooking

blade onto handle rod as shown in Figure 1. Pull blade up-

ward to open position to automatically activate light.

To turn off, push blade downward into off position and dis-

connect from handle. (See Figure 1).

Compatibility/Standards

Standard ADC

®

Satin

Laryngoscopes conform to current ISO 7376 standards. They are

compatible with virtually all major brands of standard illumination hook-on blades and

handles.

Fiberoptic ADC

®

Satin

Laryngoscopes and Disposable Laryngoscope blades conform

to current ISO 7376 standards. They are compatible with virtually all major brands of

fiberoptic illumination hook-on blades and handles. For easy visual identification, ALL

fiberoptic models are clearly delineated by a green indicator on both handle and blade.

 

O

ff

 Po

siti

o

n

Handle

 

R

o

d

P

u

ll

 

Blade

 

Up

I

nt

o O

n

Po

siti

o

n

O

n

 Po

siti

o

n

 

 

 

 

 

Figure 1

Off Position

Handle Rod

Pull Blade Up Into

On Position

On Position

Содержание Satin

Страница 1: ...ADC SatinTM Standard Fiber Optic and Disposable Laryngoscope Blades and Handles Directions for Use...

Страница 2: ...ications The following are only relative contraindication to tracheal intubation 1 Severe airway trauma or obstruction that does not permit safe passage of an endotra cheal tube Emergency cricothyroto...

Страница 3: ...ation of all Laryngoscope Models To Activate Attach selected blade onto handle by hooking blade onto handle rod as shown in Figure 1 Pull blade up ward to open position to automatically activate light...

Страница 4: ...aning and replacement WARNING Ultrasonic cleaning is not recommended Disinfection Sterilization Warnings for All Laryngoscope Blades CAUTION ADC laryngoscope blades do not come sterilized The Sterrad...

Страница 5: ...be wiped with a cloth dampened with 70 isopropyl alcohol DO NOT ALLOW SOLUTION TO ENTER INTO THE CARTRIDGE The lamp cartridge and bulb CANNOT be SOAKED OR AUTO CLAVED High Level Disinfection for Stan...

Страница 6: ...OLUTION TO ENTER INTO THE CARTRIDGE The lamp cartridge and bulb CANNOT be SOAKED OR AUTOCLAVED Steris Sterilization Processes for Disposable and Fiberoptic Laryngoscopes This product has been validate...

Страница 7: ...mp collar and rotate lamp counterclock wise until free 2 Replace the lamp with a new ADC lamp 3 Verify that lamp is sufficiently tightened before use CAUTION Be sure lamp s glass surface is clean and...

Страница 8: ...y reversing the above steps 4 Tighten the locking screw ensuring that the fiberoptic bundle is securely attached to the laryngoscope blade Figure 5 Test Procedures Laryngoscope blades and handles shou...

Страница 9: ...ELS DESCRIPTIONS Laryngoscope Item Mac 0 Mac 1 Mac 2 Mac 3 Mac 4 Miller 00 Miller 0 Miller 1 Miller 2 Miller 3 Miller 4 Wisconsin 0 Wisconsin 1 Wisconsin 1 5 Wisconsin 2 Wisconsin 3 Wisconsin 4 C Cell...

Страница 10: ...ll Handle Stubby Handle Fiberoptic Blade 4070F 4071F 4072F 4073F 4074F NA 4080F 4081F 4082F 4083F 4084F NA NA NA 4NA NA NA 4065F 4066F 4067F Fiberoptic Replacement Lamp NA NA NA NA NA NA NA NA NA NA N...

Страница 11: ...84D 20 NA NA NA NA NA NA NA 4065D 20 NA SPU MODELS DESCRIPTIONS REPLACEMENT PARTS CHART Laryngoscope Item Mac 0 Mac 1 Mac 2 Mac 3 Mac 4 Miller 00 Miller 0 Miller 1 Miller 2 Miller 3 Miller 4 Wisconsin...

Страница 12: ...ental special or consequential damages so this limitation may not apply to you To Obtain Warranty Service Send item s postage paid to ADC Attn Repair Dept 55 Commerce Dr Hauppauge NY 11788 Please incl...

Страница 13: ...it 6 PO14 1TH United Kingdom Inspected in the U S A Reusable models Made in Pakistan Disposable models Made in Taiwan China tel 631 273 9600 toll free 1 800 232 2670 fax 631 273 9659 www adctoday com...

Отзывы: