©American Audio® - www.americanaudio.eu
ELX Series
User Manual Page 23
7.7.5
DC
P
ROTECTION
If the output signal has a larger DC voltage (=2.6V), in order to protect the speaker, the DC protection circuit will startup. When the DC protection
circuit starts up, the
Protection Indicator LED
will glow and the amp will go mute.
Safe Power Levels at Different Output Loads:
8-Ohm Loads:
The amplifier can operate at practically any power level without risk of overheating. However, if it is pushed hard enough to
continually light the
Clip Indicator
, the amplifier’s average output power can reach 150 watts.
4-Ohm Loads:
If the
Clip Indicator
flashes occasionally, the amplifier is approaching its maximum long-term power capacity. If it is lit about half the
time, the amplifier channel will probably go into thermal protection within a few minutes.
7.8
A
MPLIFIER
F
EATURES
7.8.1
LINK
Link will allow the user to daisy-chain one amplifiers’ signal input into another amplifier. Plug the signal source outputs into the first amplifiers’
input, patch from the amplifiers’ LINK jacks to the next amplifiers’ input, and so on, daisy-chaining as many amplifiers as there is no excessive level
loss.
7.8.2
O
PERATING
V
OLTAGE
(AC
M
AINS
)
The correct AC main voltage is listed above the
Power Cord
input. Connecting to the wrong voltage is dangerous and may damage the amplifier.