background image

K3 and KT3 OWNER'S MANUAL

4209-42  08/06/21

Page 2 

Technical support:  1-320-286-3500        1-800-363-0251          [email protected]

IMPORTANT SAFETY INSTRUCTIONS

 

1. READ AND FOLLOW ALL INSTRUCTIONS.

 

 

2. WARNING - To reduce the risk of injury, do not permit children to use this product unless they 

 

    are closely supervised at all times.

 

3. WARNING - To reduce the risk of injury:

 

    a. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving.

 

    b. The steam head is hot. Do not touch the steam head and avoid the steam near the steam head.

 

    c. Prolonged use of the steam system can raise excessively the internal human body temperature  

 

        and impair the body’s ability to regulate its internal temperature (hyperthermia). Limit your use  

 

        of steam to 10 - 15 minutes until you are certain of your body’s reaction.

 

    d. Excessive temperatures have a high potential for causing fetal damage during the early months  

 

        of pregnancy. Pregnant or possibly pregnant women should consult a physician regarding correct

 

        exposure.

 

    e. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory  

 

        system problems, or diabetes should consult a physician before using a steambath.

 

    f. Persons using medication should consult a physician before using a steambath since some medi-

 

       cation may induce drowsiness while other medications may affect heart rate, blood pressure and 

 

       circulation.

 

4. WARNING - Hyperthermia occurs when the internal temperature of the body reaches a level several  

 

    degrees above the normal body temperature of 98.6 °F (37°C). The symptoms of hyperthermia include

 

    an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting. The  

 

    effect of hyperthermia include:

 

    a. Failure to perceive heat:

 

    b. Failure to recognize the need to exit the steambath:

 

    c. Unawareness of impending risk:

 

    d. Fetal damage in pregnant women:

 

    e. Physical inability to exit the steambath: and

 

    f. Unconsciousness.

 

 

WARNING -

 The use of alcohol, drugs or medication can greatly increase the risk of hyperthermia.

SAVE THESE INSTRUCTIONS

Содержание K3

Страница 1: ...approximately 10 minutes 6 Pressing the control s on off switch while the steam generator is operating will shut it off 7 If your steam room has a shower a pleasant experience can be achieved by taking a warm shower while in the steam You will find the contrast from water to steam quite invigorating SECTION 1 USING THE K3 KT3 WITH An AMEREC GENERATOR AK STEAM GENERATOR K3 and KT3 WARNING Electrica...

Страница 2: ...t or possibly pregnant women should consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a steambath f Persons using medication should consult a physician before using a steambath since some medi cation may induce drowsiness while other me...

Страница 3: ...ustable from 5 to 60 minutes in 5 minute increments A jumper on the steamer board may be set for a bath time settable up to 24 hours max in 1 hour increments To check the time setting turn on the steam bath then press the TIME switch The set time will immediately be displayed Continue holding the switch for 5 seconds and the setting will begin to change Continue pressing the switch and the TIME se...

Страница 4: ...ox and the tiles should be finished over the plate and up to the hole edges to leave the control s mounting hole clear See Figure 4 3 INSTALL K3 or KT3 CONTROL The low voltage K3 control can be mounted directly to a finished wall either inside or outside the steam room The low voltage KT3 control must be mounted in side the steam room See step 2 above The control cable should already be roughed in...

Страница 5: ...eaker then contact Support Water runs out of steamhead Generator Faulty 1 Turn off the breaker 2 Turn off the water supply 3 Contact Support Steam room too hot or cold Temperature setting needs changing 1 See section 3 Setting Time and Temp 2 Contact Support Control ON Displays Steambath temperature over 132 F 55 C or Sensor faulty 1 If the bath is too hot turn off the circuit breaker and contact ...

Страница 6: ...his procedure should be scheduled monthly or more often depending on local water conditions and steam bath usage Flushing Procedure The generator should be cool before starting 1 Use the control to start a bath Immediately go to the generator and open the manual drain open is with the handle in line with the drain pipe closed has the handle pointing straight out over the side of the pipe 2 Allow t...

Отзывы: