  SECTION  5:  MAINTENANCE OF YOUR  AK STEAM GENERATOR

The steam generator, steam head, fittings and plumbing connections should be inspected regularly for water leaks and damage. The AK steam generator is supplied 

with a manual drain valve for flushing sediments from the generator tank; an optional automatic electronic drain is available as an option. The autodrain option drains 

and rinses the bath after each use. If only a manual drain is available, the steam generator should be manually drained periodically following the Flushing Procedure 

shown here. This procedure should be scheduled monthly or more often depending on local water conditions and steam bath usage.

Flushing Procedure

:  

The generator should be cool before starting.

1. Use the control to start a bath. Immediately go to the generator and open the manual drain (open is with the handle in line with the drain pipe, closed has the

    handle pointing straight out over the side of the pipe).

2. Allow the tank to drain for a couple minutes then close the drain and allow the tank to fill for about 1 minute.

3. Open the drain again and allow the water to run with the drain open for a full 10 minutes with the bath turned on.

4.  Use the control to turn the bath off then go to the generator. When the water stops flowing out the drain, close the manual drain valve.

Technical Support

575 Cokato St E

Cokato, MN 55321

Phone 320-286-3500

            1-800-363-0251
email: [email protected]

Содержание K3

Страница 1: ...approximately 10 minutes 6 Pressing the control s on off switch while the steam generator is operating will shut it off 7 If your steam room has a shower a pleasant experience can be achieved by taking a warm shower while in the steam You will find the contrast from water to steam quite invigorating SECTION 1 USING THE K3 KT3 WITH An AMEREC GENERATOR AK STEAM GENERATOR K3 and KT3 WARNING Electrica...

Страница 2: ...t or possibly pregnant women should consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a steambath f Persons using medication should consult a physician before using a steambath since some medi cation may induce drowsiness while other me...

Страница 3: ...ustable from 5 to 60 minutes in 5 minute increments A jumper on the steamer board may be set for a bath time settable up to 24 hours max in 1 hour increments To check the time setting turn on the steam bath then press the TIME switch The set time will immediately be displayed Continue holding the switch for 5 seconds and the setting will begin to change Continue pressing the switch and the TIME se...

Страница 4: ...ox and the tiles should be finished over the plate and up to the hole edges to leave the control s mounting hole clear See Figure 4 3 INSTALL K3 or KT3 CONTROL The low voltage K3 control can be mounted directly to a finished wall either inside or outside the steam room The low voltage KT3 control must be mounted in side the steam room See step 2 above The control cable should already be roughed in...

Страница 5: ...eaker then contact Support Water runs out of steamhead Generator Faulty 1 Turn off the breaker 2 Turn off the water supply 3 Contact Support Steam room too hot or cold Temperature setting needs changing 1 See section 3 Setting Time and Temp 2 Contact Support Control ON Displays Steambath temperature over 132 F 55 C or Sensor faulty 1 If the bath is too hot turn off the circuit breaker and contact ...

Страница 6: ...his procedure should be scheduled monthly or more often depending on local water conditions and steam bath usage Flushing Procedure The generator should be cool before starting 1 Use the control to start a bath Immediately go to the generator and open the manual drain open is with the handle in line with the drain pipe closed has the handle pointing straight out over the side of the pipe 2 Allow t...

Отзывы: