INSTALLATION AND OPERATING INSTRUCTIONS
72-0106 02-26-16
7013482 314 SKSM 215 B
Page 7
WARNING
SECTION 7: CONTROL INSTALLATION & OPERATION
Do not locate benches over
heater. Minimum clearance
of ceiling above heater 44".
Minimum clearance from
heater to wooden surfaces
(benches, side walls, heater
fence etc.) 2 inches.
Mounting brackets supplied.
Provides proper clearance
from wall behind heater.
Use only copper wire of the
size and type indicated in the
Heater Specication Chart
and the temperature rating
indicated on the heater
junction box.
All heaters and controls must
be grounded per NEC to
prevent electrical shock in
case of unit failure.
Electrical outlets or
receptacle must not be
installed in a sauna room.
A guardrail or fence is
required around the heater to
prevent burns from
accidental contact.
INSTALLATION ROUGH IN: Place the control inside or outside the sauna room. If
the control is installed inside a sauna room, the top of the unit cannot be higher
than 35 inches above oor.
String low voltage control cable through 1” holes in the wall studs or ceiling joists
from the control location to the heater. Do not use staples to secure the low
voltage cable, it may damage the cable! Plug the control cable into the control
and push any excess cable into wall cavity before securing control to the wall.
Maximum control cable length is 50 feet.
Remove the adhesive tape from the back of the the control, place the control so
the hole for the retainer screw is facing downwards, insert control into the wall
and press the control to the mounting surface.
A.
On/Off Light switch
B.
Indicators - lights for lighting, door switch (n/a), timer and the heater
C.
On/Off Sauna Switch and fault alarms
D.
Sets the desired value
E.
Functions - Temperature, Delay Timer, Sauna Length and Humidity (n/a)
F.
Function buttons
CONTROL OPERATION:
TURN ON LIGHT: Press the "light bulb" icon once to turn on the light and press
again to turn off. (Usage of light control is optional)
SAUNA LENGTH: (Control 1601-31) Select the sauna length function by pressing
the buttons < > (F). Set the desired usage time (0–60 minutes) using the – and +
buttons. (Setting 10 equals 60 minutes)
(Control 1601-31-1) Usage time is 0-24 hours operation
(Setting 1 = 2 hours, setting 10 = 23 hours)
SET TEMPERATURE: Press function button (F). Then you can choose the desired
temperature 1–10 using buttons – and +. (Setting 10 equals highest set point.)
When the desired temperature has been set and the heater is switched on the set
temperature indicator light will remain on and the current temperature indicator LED
will ash. When the current temperature reaches the set value the indicator light will
stop ashing.
A. B. C.
D.
E.
F.