background image

INSTALLATION AND OPERATING INSTRUCTIONS

72-0106    02-26-16                                                                                                                                                                                                                            

                               7013482      314 SKSM 215 B

Page 12

     SECTION 14: TROUBLESHOOTING

Control will Run but No Heat -  Press the (reset) high limit switch on the bottom of heater.

Slow Heat Time or High Limit Tripping - Check rock placement, they will break down over time and reduce the air 
ow in the heater. Refer to Diagram 10 for proper rock installation. Discard all rocks under the size of 2" pieces. Call 
the number below to order more rocks if needed.

In the event of a fault occurring in the heater system (control panel, temperature sensor, etc.), this will be signaled 
by the LED indicator light on the control panel. The fault indicator light will be displayed on the 1-10 scale of the 
control. The fault error code will be displayed with a constant LED light or a ashing LED light. See the list below for 
fault codes.  
 
                     

Constant LED Fault Code (ones marked with “n/a” are not in use):

1   Temperature sensor not connected or shorted
2   n/a
3   Heater circuit board overheated
4   n/a
5   n/a
6   Communication lost between control and circuit board in heater.
7   n/a
8   n/a
9   n/a
10 n/a

Flashing LED Fault Code

1   n/a
2   n/a
3   n/a
4   n/a
5   n/a
6   n/a
7   n/a
8   n/a
9   Door Switch is open for more than 60 seconds while heating or jumper on circuit board in heater is removed.
10 Door Switch is open for more than 60 seconds in “Delay” Mode or jumper on circuit board in heater is removed.

For troubleshooting or service questions call 1-888-780-4427 and ask to speak with service. Prior to calling, please 
have the Model and Type number available. You may also email us at 

[email protected]

 

Содержание Designer 4.5

Страница 1: ...ntrol Type 1601 31 and 1601 31 1 Read all instructions carefully before installation Please leave all instructions and warranty with the owner WARNING Prolonged exposure to elevated temperatures is ca...

Страница 2: ...STANCE B DISTANCE C DISTANCE D DISTANCE K DISTANCE Designer 4 5 3 0 3 5 8 4 0 11 1 2 23 Designer 6 0 4 0 4 5 8 5 0 11 1 2 23 Designer 8 0 5 0 5 5 8 6 0 11 1 2 23 HEATER MINIMUM WIRE SIZE Floor Area Ce...

Страница 3: ...rvice to this equipment should be performed by quali ed licensed personnel in accordance with local and national codes Do not construct sauna room so as to restrict air ow through the bottom of the he...

Страница 4: ...above the heater Insert screwdriver tip here to unsnap sensor cover from sensor Note vertical orientation of cover before removing Diagram 4 was intentionally left blank Sensor protective cover Locat...

Страница 5: ...2 3 02 26 2016 P1 P2 P3 1 3 5 7 A1 2 4 6 8 A2 X1 X2 X3 X5 X7 X4 X6 X8 X9 X10 N N H Trans former 120 Volt Light Output 2 0 Amp Max Connect L1 to terminals 1 2 and 5 Connect L2 to terminals 3 4 and 6 C...

Страница 6: ...26 2016 P1 P2 P3 1 3 5 7 A1 2 4 6 8 A2 X1 X2 X3 X5 X7 X4 X6 X8 X9 X10 N N H 2 3 Trans former 120 Volt Light Output 2 0 Amp Max 3 Phase Connection Connect L1 to terminals 1 and 2 Connect L3 to terminal...

Страница 7: ...the control and push any excess cable into wall cavity before securing control to the wall Maximum control cable length is 50 feet Remove the adhesive tape from the back of the the control place the c...

Страница 8: ...stopped Some sauna bathers enjoy the soothing effect of steam by splashing water on the heated sauna rocks Use only one dipper full approx cup at a time and keep clear of the steam as it rises off the...

Страница 9: ...and the outer wall will reduce cycling of the heater b Rocks must be placed between the elements and the wall of the rock compartment Incorrect Placement of Rocks a Loosely place rocks between the ele...

Страница 10: ...The enclosed CAUTION Reduce the risk of re caution plate must be mounted on the interior wall above the heater The heater should not be operated without its container properly lled with rocks and the...

Страница 11: ...a oor mopped and dried in a conventional manner and the duckboard thoroughly scrubbed and dried before returning to the sauna room The sauna heater should be wiped down occasionally with a damp cloth...

Страница 12: ...scale of the control The fault error code will be displayed with a constant LED light or a ashing LED light See the list below for fault codes Constant LED Fault Code ones marked with n a are not in...

Отзывы: