v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Beep
code
Description
Action
3-1-1
Timer
tick
interrupt
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
3-1-2
Interval
timer
channel
2
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
3-1-3
RAM
test
failed
above
address
0FFFFh.
1.
Reseat
the
DIMMs.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
3-1-4
Time-of-day
clock
failed.
1.
Reseat
the
battery.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Battery
b.
(Trained
service
technician
only)
System
board
assembly
3-2-1
Serial
port
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
3-2-3
Math
coprocessor
test
failed
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
assembly
3-2-4
Failure
comparing
CMOS
memory
size
against
actual
1.
Reseat
the
following
components:
a.
DIMMs
b.
Battery
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
c.
Battery
Chapter
2.
Diagnostics
13
Содержание Opteron LS20
Страница 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 70: ...56 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 102: ...88 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 112: ...98 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 113: ......
Страница 114: ...Part Number 24R9677 Printed in USA 1P P N 24R9677...