Glossary
182
3ware 9000 Series Serial ATA RAID Controller User Guide
preserved on the paired drive. Mirrored disk arrays include RAID 1 and
RAID 10.
Non-redundant units.
A disk array without fault tolerance (RAID 0,
single disk, or JBOD.).
OCE (Online Capacity Expansion).
The process of increasing the size of
an existing RAID unit without having to create a new array.
Parity.
Information that the controller calculates using an exclusive OR
(XOR) algorithm and writes to the disk drives in RAID 5 and RAID 50
units. This data can be used with the remaining user data to recover the
lost data if a disk drive fails.
PCB
. Printed circuit board.
P-Chip.
PCI interface chip that connects the PCI bus to the high-speed
internal bus and routes all data between the two using a packet switched
fabric. There is one P-chip per controller card.
Port ID
. A unique identifier for a specific port in a system. Also called a
drive ID.
Rebuild task schedule
. The specification for when rebuilding, may
occur, including start time and duration.
Rebuild a unit
. To generate data on a new drive after it is put into service
to replace a degraded drive in a fault tolerant unit (for example, RAID 1,
10, 5, or 50).
Redundancy.
Duplication of data on another drive or drives, so that it is
protected in the event of a drive failure.
Remove a drive.
The process of making a drive unavailable to the
controller.
Remove a unit.
The process of making a unit unavailable to the
controller and the operating system. After a unit is removed it can be hot
swapped out of the system.This is sometimes referred to as exporting a
unit.
RLM (RAID Level Migration).
The process of using an existing unit of
one or more drives and converting it to a new RAID type without having
to delete the original unit. For example, converting a single disk to a
mirrored disk or converting a RAID 0 unit to a RAID 5 unit.
Self-test.
A unit test that can be performed on a scheduled basis. in 3DM,
available self-tests include Upgrade UDMA mode and Check SMART
Thresholds.
Stagger time.
The delay between drive groups that will spin up, at one
time, on a particular controller.
Stripe size
. The size of the data written to each disk drive in RAID unit
levels that support striping. The size of stripes can be set for a given unit
Содержание 3ware 9000 Series
Страница 1: ...3ware Serial ATA RAID Controller Supports the 9000 Series PN 720 0114 01 March 2005 User Guide...
Страница 10: ...About This Guide 4 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 88: ...Configuring Your Controller 82 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 144: ...Maintaining Units 138 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 184: ...Troubleshooting Problems and Solutions 178 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 190: ...Glossary 184 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 196: ...Appendix B Warranty Technical Support and Service 190 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 202: ...196 3ware 9000 Series Serial ATA RAID Controller User Guide...