AEN Messages
www.3ware.com
175
AEN 04Ch AEN_TEMPERATURE_BELOW_OPERATING
The Battery Backup Unit measures and evaluates the battery pack
temperature on a continuous basis. If the temperature is too low to operate,
this AEN will be posted to the user. When this event happens, the Battery
Backup Unit becomes not ready and is unable to backup the 3ware RAID
controller. The user must replace the battery pack.
AEN 04Dh AEN_TEMPERATURE_ABOVE_OPERATING
The Battery Backup Unit measures and evaluates the battery pack
temperature on a continuous basis. If the temperature is too high to operate,
this AEN will be posted to the user. The user should check that there is
enough airflow around the Battery Backup Unit. When this event happens, the
Battery Backup Unit becomes not ready and is unable to backup the 3ware
RAID controller. The user must replace the battery pack if the temperature
error persists. The use of a PCI card in the slot adjacent to the BBU is not
recommended and may result in the battery temperature being exceeded.
AEN 04Eh AEN_LOW_CURRENT_TEST_STARTED
This AEN is posted when the Battery Backup Unit starts a battery test. The
test estimates the battery capacity in hours, which is how long the Battery
Backup Unit can back up the 3ware RAID controller. This test performs a full
battery charge/discharge/re-charge cycle and may take up to 20 hours to
complete. During this test the Battery Backup Unit cannot backup the 3ware
RAID controller; all units have their write cache disabled until the test
completes.
AEN 04Fh AEN_CACHE_SYNC_SKIPPED
The 3ware RAID controller performs cache synchronization when system
power is restored following a power failure. This AEN is posted when the
cache synchronization was skipped and write data is still being backed up in
the controller cache. This can occur if a unit that was present before the power
failure was physically removed or became inoperable before system power
was restored.
AEN 050h AEN_LOW_CURRENT_TEST_STOPPED
This AEN is posted when the Battery Backup Unit completes a battery
capacity test. All units will have their write cache settings restored to their
original values since the Battery Backup Unit is now able to backup the 3ware
RAID controller.
Содержание 3ware 9000 Series
Страница 1: ...3ware Serial ATA RAID Controller Supports the 9000 Series PN 720 0114 01 March 2005 User Guide...
Страница 10: ...About This Guide 4 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 88: ...Configuring Your Controller 82 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 144: ...Maintaining Units 138 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 184: ...Troubleshooting Problems and Solutions 178 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 190: ...Glossary 184 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 196: ...Appendix B Warranty Technical Support and Service 190 3ware 9000 Series Serial ATA RAID Controller User Guide...
Страница 202: ...196 3ware 9000 Series Serial ATA RAID Controller User Guide...