background image

www.amcelettronica.com

Installation Instructions

soutdoor L

SOUTDOOR

Input Voltage

0.5 to 13.8 V

Current Drain (Alarm / Stand-By)

25 mA / 14 mA @ 13.8V

Coverage

6/12 m 

Aperture Angle

90°

2 PIR / Pyroelectric

full digital

Lens 1

Fresnel (22 Patterns on 3 levels)

Lens 2

Fresnel horizontal curtain (11 Patterns 1 level)

OPTIONAL Lens

Fresnel, vertical (11 Patterns 11 level)

Alarm period

2 sec.

Anti-opening

Back Tamper

Alarm contact

0.2 A - 24 Vcc 

Tamper Switch

Max 40 mA - 30 Vcc

Operating Temperature

From -30 °C to +55 °C 

Storage Temperature

From -30 °C to +60 °C 

RFI Protection

30 V / m (80 /1000 MHz)*

Walk Test LED (MW and PIR)

Housing / Cover

ABS

Dimensions

185 X 85  X 70 mm 

weight

265Gr

technicaL features 

Installation must be performed according to accepted standards by specialized personnel.

The manufacturer shall not be responsible if the product is tampered with by unauthorised persons. 

We recommend that you check the correct operation of the alarm system at least once per month. A reliable electronic 

alarm system does not prevent intrusions, robberies, fires or other occurrences but simply reduces the risk of occurrence.

Installation must be carried out following the local installation norms by qualified personnel. 

The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.

It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and 

due to, but not limited to, any or all of the following: tampering, electrical or communication disruption or improper use, it 

is possible for the product/system to fail to prevent burglary, rubbery, fire or otherwise. A properly installed and maintained 

alarm system can only reduce the risk that this happens. 

Содержание soutdoor L

Страница 1: ...centage of false alarms With hight thermal variations the totally digital temperature compensation system guarantees a great performance Has 15mt coverage with angle of 90 With usable different type o...

Страница 2: ...ed Dip switches EOL resistor jumpers Walk test LED anti opening height adjustment board Installation Place the sensor at a height of between 1 m and 2m Important placement should be chosen depending o...

Страница 3: ...ing the direction of the beams As you can see in the picture below you can slide the board inside the cover FUNCTIONS Sliding system detail board The sliding is opposite to the beam so when the board...

Страница 4: ...UNCTIONS 1 2 3 4 5 6 FUNCTIONS 1 2 3 4 5 6 FUNCTIONS Coverage diagrams based on board position Note the figures show the effect of the beams based on the position of the board Since they are purely in...

Страница 5: ...ackage there are 3 types of lenses Horizontal curtain lens Fig 1 Vertical curtain lens fig 2 Volumetric curtain lens fig 3 On the sensors are mounted by default on the PIR1 top the volumet ric lens an...

Страница 6: ...the beam range This way you have a variable height protection from 35 40 cm from the ground and up to 1 6 cm high with a horizontal coverage of about 80 100 degrees With this configuration you can ac...

Страница 7: ...be positioned towards the outside Important the volumetric lens has one direction therefore pay close attention to how it is positioned When put up against the light you can see how the FRESNEL lenses...

Страница 8: ...nt the positioning mentioned previously Note remember that the distance between the board and the base is 13 5 mm Space reserved for the proper positioning of the cable feeder or any piping to be inse...

Страница 9: ...he manufacturer shall not be responsible if the product is tampered with by unauthorised persons We recommend that you check the correct operation of the alarm system at least once per month A reliabl...

Отзывы: