background image

 

In accordance to the standard 

EN 50131-2-4 Grade 2 

Enclosure material 

ABS 

Accessories  

Rotary handle (SN-1 version)* 

Dimensions (H x W x D) 

110 x 60 x 46mm 

Resistance to animals  

NO 

 
 

In accordance with the standards: 
 
R&TTE 99/5/CE  
EN 50131-2-4: 2008  
EN 50131-2-4 Grade 2  
EN 50131-2-4 Class 2  
CEI 79-2: II° Level
 

 

 

RoHS 

 

 

 

*

The holder does not comply with the EN 50131-2-4 standard 

 

Additional information 

The  manufacturer  takes  no  responsibility  for  the  defects  that  result  from  the  damaging,  malfunctioning  or 
inability to operate the equipment especially when resulting from failure to comply with the recommendations 
and requirements contained in the manual. 

It  is  necessary  to  periodically  test  the  signaling  device.  The  majority  of  Intrusion  Detection  Systems 

indicates  malfunctioning  of  the  signaling  devices and  informs  the  user  with  an  appropriate  message  on  the 
LCD  keypad  or  LED  light  on  the  LED  display.  In  case  of  such  situation,  the  system  installer  shall  be  
immediately notified. Testing and control  methods of Intrusion Detection Systems are specifically determined 
by the installer. 

The  MOUSE  01  detector  was  made  in  accordance  with  the  requirements  of  the  EEC  and  99/5/CE 

directives. The Declaration of Conformity is available at 

www.pulsar.pl

  

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание MOUSE 01

Страница 1: ...r operation is shown in the Figure 5a and 5b The anti masking function is based on the microwave sensor If the microwave sensor detects any object in a distance of several centimeters from the detector it is interpreted as an attempt to block the detector and causes the opening of the NC anti masking relay for about 2 seconds 2 Installation of the detector The detector should be mounted by a quali...

Страница 2: ... with a description of the available functions can be found in the following pages 6 Close the lid of the sensor CAUTION When closing the cover of the detector check whether the spring of the micro switch tamper is correctly pressed into the tapered socket in the lid The field of view of the detector should not be partially or completely obstructed 7 Connect the supply voltage and wait until the L...

Страница 3: ... the protected space Microwaves can penetrate gypsum walls doors etc which may generate false alarms 2 Three position ON OFF potentiometer selection of additional functions The following functions can be activated with the dip switch turning of the microwaves alarm memory DUO MASK function See description below in Table 1 Table 1 Elements of the detector configuration Dip switch switches Descripti...

Страница 4: ...th PIR and WM detectors in case of intruder detection 3 The tamper disable jumper If the tamper indicating enclosure opening will be used in addition to the tamper indicating detachment from the wall remove the JP jumper Turning off the microwaves an example of use of the function The use of dual element detectors especially when using the PIR and MW detectors in the AND mode alarm by both detecto...

Страница 5: ...1 Power supply 9 15VDC Power consumption Alarm Standby 26 0mA 18 5mA 13 8VDC Sensor range up to 14m Operating angle 90 PIR Sensor 2 components Lens 29 areas in 5 levels Microwave frequency 10 525GHz Emission of microwave signals 1mW impulses Alarm signaling time 4s Alarm type AND OR Tamper protection opening of the detector detachment from the wall YES YES Creep zone detection YES Maximum load of ...

Страница 6: ... equipment especially when resulting from failure to comply with the recommendations and requirements contained in the manual It is necessary to periodically test the signaling device The majority of Intrusion Detection Systems indicates malfunctioning of the signaling devices and informs the user with an appropriate message on the LCD keypad or LED light on the LED display In case of such situati...

Страница 7: ...venience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has beenconditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manu...

Отзывы: