background image

 

 

 

 

The exclusive distributor of AMC products 

 

MOUSE 01 

Dual Element Digital Motion Detector (dual pyro 
e mic anti-masking)

 

 

CODE 

MU01 

 

In accordance with the 

EN 50131-2-4 standard

 

MANUAL  EN

 

 

Edition: 3 from 07.03.2014 

Supersedes: 2 from 24.02.2014

 

 

1. Introduction 

 

     The MOUSE 01 is a dual element digital motion detector with anti-masking function.  

With  its  advanced  signal  processing  algorithms  and  dual  detection  technology  (PIR  and  MW)  it  is 

characterized  by  very  stable  operation  and  low  rate  of  false  alarms.  Advanced  digital  temperature 
compensation enables operation over a wide temperature range.  

The  range  of  the  MOUSE  01  detector  is  up  to  14  meters.  Special  lens  provides  horizontal  coverage 

exceeding  90  degrees  (29  zones  in  5  levels).  The  detector  features  creep  zone  detection.  The  area  of  the 
sensor operation is shown in the Figure 5a and 5b. 

The anti-masking function is based on the microwave sensor. If the microwave sensor detects any object 

in a distance of several centimeters from the detector, it is interpreted as an attempt to block the detector and 
causes the opening of the NC anti-masking relay for about 2 seconds.  
 

2. Installation of the detector 

 

The detector should be mounted by a qualified installer, holding relevant permits and licenses (applicable and 
required for a given country) for Intrusion Detection Systems. 
The latch system used in the enclosure of the detector eliminates the need for screw connections, so that the 
detector installation is simple and does not take much time.  

Follow the basic rules for the installation of Intrusion Detection Systems (pay attention, among others, not 

to 

soil 

or 

damage 

the 

pyroelectric 

element, 

do 

not 

point 

the 

detector 

towards strong light sources).). The optimum mounting height of the MOUSE 01 detector is 2 meters. 

 
 

 
 
 

 

 

 

 

Fig. 1a 

Main view

 

Fig. 2 b 

Inside view

 

 

 
 
 
 

Содержание MOUSE 01

Страница 1: ...r operation is shown in the Figure 5a and 5b The anti masking function is based on the microwave sensor If the microwave sensor detects any object in a distance of several centimeters from the detector it is interpreted as an attempt to block the detector and causes the opening of the NC anti masking relay for about 2 seconds 2 Installation of the detector The detector should be mounted by a quali...

Страница 2: ... with a description of the available functions can be found in the following pages 6 Close the lid of the sensor CAUTION When closing the cover of the detector check whether the spring of the micro switch tamper is correctly pressed into the tapered socket in the lid The field of view of the detector should not be partially or completely obstructed 7 Connect the supply voltage and wait until the L...

Страница 3: ... the protected space Microwaves can penetrate gypsum walls doors etc which may generate false alarms 2 Three position ON OFF potentiometer selection of additional functions The following functions can be activated with the dip switch turning of the microwaves alarm memory DUO MASK function See description below in Table 1 Table 1 Elements of the detector configuration Dip switch switches Descripti...

Страница 4: ...th PIR and WM detectors in case of intruder detection 3 The tamper disable jumper If the tamper indicating enclosure opening will be used in addition to the tamper indicating detachment from the wall remove the JP jumper Turning off the microwaves an example of use of the function The use of dual element detectors especially when using the PIR and MW detectors in the AND mode alarm by both detecto...

Страница 5: ...1 Power supply 9 15VDC Power consumption Alarm Standby 26 0mA 18 5mA 13 8VDC Sensor range up to 14m Operating angle 90 PIR Sensor 2 components Lens 29 areas in 5 levels Microwave frequency 10 525GHz Emission of microwave signals 1mW impulses Alarm signaling time 4s Alarm type AND OR Tamper protection opening of the detector detachment from the wall YES YES Creep zone detection YES Maximum load of ...

Страница 6: ... equipment especially when resulting from failure to comply with the recommendations and requirements contained in the manual It is necessary to periodically test the signaling device The majority of Intrusion Detection Systems indicates malfunctioning of the signaling devices and informs the user with an appropriate message on the LCD keypad or LED light on the LED display In case of such situati...

Страница 7: ...venience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has beenconditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manu...