The  alarm  memory  function  activation.  This  feature  enables 
quick  determining  which  detector  triggered  the  alarm. 
This is indicated by slow flashing LEDs. The LED color indicates 
which 

detector 

triggered 

the 

alarm. 

Red  LED  -  –  the  alarm  is  generated  by  both  PIR  and  WM 
detectors.  Green  LED  –  alarm  by  microwave  detector  (OR 
configuration. only). 
Orange LED – alarm by PIR detector (OR configuration. only). 
This function is implemented by the B/S terminal. 
The configuration is the same as for the MW detector. 
The alarm memory is reset each time the control panel is armed. 

DIP 2 
Alarm memory function 

OFF 

Turning off the alarm memory. 

ON 

Switching  on  the  DUO-MASK  function.  This  is  a special  feature 
allowing  to  determine  when  infrared  or  microwave  is  masked. 
The  alarm  is  generated  after  four-detections  of  the  MW  or  PIR 
detector  within  40  seconds  after  the  first  activation.  After  this 
time, the detector is zeroed. 

DIP 3 
DUO-MASK function 

OFF 

The detector operates in the AND  mode. The alarm is generated 
by both PIR and WM detectors in case of intruder detection. 

 

3. The „tamper disable” jumper 
If the tamper indicating enclosure opening will be  used in addition to the tamper indicating detachment from 
the wall, remove the JP jumper.  
 

Turning off the microwaves – an example of use of the function. 

The  use  of  dual  element  detectors,  especially  when  using  the  PIR  and  MW  detectors  in  the  
„AND”  mode  (alarm  by  both  detectors  in  case  of  intruder  detection),  allows  to  reduce  to  a  minimum  the 
amount of false alarms.  

However, long-term exposure to microwave radiation is harmful to health, and therefore the MOUSE 01 

has a feature to block the microwave detector when the Intrusion Detection System is disarmed. 

The diagram of connecting the sensor to the control panel with a brief description of the implementation 

of this feature is shown below.  

 

 

 

The diagram of connecting the MOUSE 01 detector to the control panel to use the locking function of 

microwave detector and the alarm memory function. 

 
 
The  OUT3  output  of  the  control  panel  is  programmed  as  the  power  supply  output  (+12V),  while  the  OUT5 
output is programmed as the standby indicator. 

The "B / S" control input, which is shorted to ground, is used to control the detector.  
 
 

Содержание MOUSE 01

Страница 1: ...r operation is shown in the Figure 5a and 5b The anti masking function is based on the microwave sensor If the microwave sensor detects any object in a distance of several centimeters from the detector it is interpreted as an attempt to block the detector and causes the opening of the NC anti masking relay for about 2 seconds 2 Installation of the detector The detector should be mounted by a quali...

Страница 2: ... with a description of the available functions can be found in the following pages 6 Close the lid of the sensor CAUTION When closing the cover of the detector check whether the spring of the micro switch tamper is correctly pressed into the tapered socket in the lid The field of view of the detector should not be partially or completely obstructed 7 Connect the supply voltage and wait until the L...

Страница 3: ... the protected space Microwaves can penetrate gypsum walls doors etc which may generate false alarms 2 Three position ON OFF potentiometer selection of additional functions The following functions can be activated with the dip switch turning of the microwaves alarm memory DUO MASK function See description below in Table 1 Table 1 Elements of the detector configuration Dip switch switches Descripti...

Страница 4: ...th PIR and WM detectors in case of intruder detection 3 The tamper disable jumper If the tamper indicating enclosure opening will be used in addition to the tamper indicating detachment from the wall remove the JP jumper Turning off the microwaves an example of use of the function The use of dual element detectors especially when using the PIR and MW detectors in the AND mode alarm by both detecto...

Страница 5: ...1 Power supply 9 15VDC Power consumption Alarm Standby 26 0mA 18 5mA 13 8VDC Sensor range up to 14m Operating angle 90 PIR Sensor 2 components Lens 29 areas in 5 levels Microwave frequency 10 525GHz Emission of microwave signals 1mW impulses Alarm signaling time 4s Alarm type AND OR Tamper protection opening of the detector detachment from the wall YES YES Creep zone detection YES Maximum load of ...

Страница 6: ... equipment especially when resulting from failure to comply with the recommendations and requirements contained in the manual It is necessary to periodically test the signaling device The majority of Intrusion Detection Systems indicates malfunctioning of the signaling devices and informs the user with an appropriate message on the LCD keypad or LED light on the LED display In case of such situati...

Страница 7: ...venience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has beenconditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manu...

Отзывы: