background image

8  

www.amcelettronica.com

IT-2000

Installation must be carried out following the local installation norms by qualified personnel. 

The factory refuses any responsibility when changes or unauthorized repairs are made to the product/sys-

tem. It is recommended to test the operation of the alarm product/system at least once a month. Despite 

frequent testing and due to, but not limited to, any or all of the following: tampering,  electrical or com-

munication disruption or improper use,  it is possible for the product/system to fail to prevent burglary, 

robbery, fire or otherwise. A properly installed and maintained alarm system can only reduce the risk that 

this happens. 

Any GSM speech dialler or communicator, not connected to the PSTN standard telephone line, does not 

ensure proper communication in case of problems or limitations due to the GSM network.  

Содержание IT-2000

Страница 1: ...configu ration 2 LOW BATTERY Battery fail the battery status is tested every 15 minutes 3 GSM NO LINE GSM fail this message is sent as soon as the GSM network becomes available after a programmable o...

Страница 2: ...AND CONNECTIONS LAYOUT ATTENTION introduce a SIM card with no data stored in its memory no tele phone numbers in address book and no text messages The SIM card insertion and extraction operations must...

Страница 3: ...rk not available SIM card locked low battery level If the problem is related to GSM network the RED and the YELLOW LEDs will blink simultaneously NOTE the battery status can be tested only when the vo...

Страница 4: ...knowledged SIM CARD AND PIN CODE The system normally works with SIM cards without the PIN code If the SIM card cannot work without the PIN code it must programmed to the 1234 value the board will use...

Страница 5: ...even if the PSTN line is available lftime 10 Sets the lifetest time to 10 minutes LFDELAY Command to set the lifetest interval in hour units lfdelay 24 Lifetest signal activation and SMS dispatch wil...

Страница 6: ...y life test PWD OK SMSTEXT 1 OK life test Because of the presence spaces in the text only the my text will be accepted life and test words will be intepreted as commands and will be not recognized PWD...

Страница 7: ...rrent 110mA Maximum current 600 mA peak 1A Battery 12V 2Ah Tamper Protection IP30 Fuse Type F 5x20 mm 1A Emulated line tone 440 Hz Emulated line voltage 33Vdc Housing Plate RAL 9002 Size 200 x 260 x 4...

Страница 8: ...onth Despite frequent testing and due to but not limited to any or all of the following tampering electrical or com munication disruption or improper use it is possible for the product system to fail...