background image

4  

www.amcelettronica.com

IT-2000

PROGRAMMING AND MANAGEMENT WITH SMS TEXT MESSAGES

USE OF THE SMS TEXT MESSAGES FOR REMOTE PROGRAMMING

As already explained, IT-2000 is completely configurable by means of SMS text messages.

To program the system, the user must send a text message suitably formatted.

A command can be composed by more fields separated by a space character: each field is composed by a 

command id, an optional command index, an operator and a value (

ID[.index]operator[value]

)

The first field of a command text must be the password declaration in order to authenticate the user access 

(e.g.; 

PWD:000000

) .

The following operators are recognized by the system:

Operator

Name

Example

:

Declarator

PWD:111111    This statement declares the password value

=

Assignment

TEL.3=1234    This statement assignes the 123456 value to the third phone 

number

?

Request

PFX?              This statement asks the system to return the PFX parameter 

value

After receiving a SMS, the system will execute the command(s) and will answer with a SMS containing the 

result of each single command. 

For example, after receiving the “PWD:000000 TEL1.1=24 “ SMS, the “PWD:OK TEL.1:OK” SMS will be 

returned. 

A wrong field will be answered with the *FAIL* indication while a not recognized field will be answered with 

the *?* indication.

Commands are CASE UNSENSITIVE and may be written either in capital letters or in small letters.

WARNING:

 incoming messages exceeding 64 characters will  be ignored and will be not acknowledged.

SIM CARD AND PIN CODE

The system normally works with SIM cards without the PIN code. If the SIM card cannot work without the 

PIN code it must programmed to the 

1234 

value: the board will use that code to use the SIM card.

USE OF THE INTERFACE WITH A TELEPHONE EXCHANGE SYSTEM

When the IT-2000 is connected to a telephone exchange, the number generated by the alarm system may 

contain a prefix that must be skipped when forwarded to the GSM network (eg: the 0 065487954 number 

must exit as 065487954).

This can be done through a suitable system setup (see the relevant paragraph).

NOTES

To avoid damages, when working on the PSTN line, IT-2000 doesn’t generate any ring signal at the 

occurrence of an incoming call from the GSM network.

At system reset, all SMS messages are associated to the first telephone number (if any): to modify 

this setting it is necessary to send a suitable command to the unit (smstel.x=0)

RESET (DEFAULT) BUTTON

To return to the initial default programming condition the system must be turned off (disconnecting supply 

and battery) and then turned on with the RESET KEY (SW1) pressed. 

The are two type of system reset:

1° PASSWORD RESET: 

if the key is pressed for about 5 seconds only the system password is reset 

2° TOTAL RESET: 

if the reset  key is pressed for more than 10 seconds the system will resume the default    

    configuration

REMARK: during reset the RED LED is turned ON, the GREEN LED blinks and, only for TOTAL RESET, the YELLOW LED 

gives a short flash.

DIAL TONE

 IT-2000 is able to generate either a continuous dial tone (default setting) or a pulsed dial tone.

To change the setting a suitable SMS command must be sent (PULSE=on/off).

Содержание IT-2000

Страница 1: ...configu ration 2 LOW BATTERY Battery fail the battery status is tested every 15 minutes 3 GSM NO LINE GSM fail this message is sent as soon as the GSM network becomes available after a programmable o...

Страница 2: ...AND CONNECTIONS LAYOUT ATTENTION introduce a SIM card with no data stored in its memory no tele phone numbers in address book and no text messages The SIM card insertion and extraction operations must...

Страница 3: ...rk not available SIM card locked low battery level If the problem is related to GSM network the RED and the YELLOW LEDs will blink simultaneously NOTE the battery status can be tested only when the vo...

Страница 4: ...knowledged SIM CARD AND PIN CODE The system normally works with SIM cards without the PIN code If the SIM card cannot work without the PIN code it must programmed to the 1234 value the board will use...

Страница 5: ...even if the PSTN line is available lftime 10 Sets the lifetest time to 10 minutes LFDELAY Command to set the lifetest interval in hour units lfdelay 24 Lifetest signal activation and SMS dispatch wil...

Страница 6: ...y life test PWD OK SMSTEXT 1 OK life test Because of the presence spaces in the text only the my text will be accepted life and test words will be intepreted as commands and will be not recognized PWD...

Страница 7: ...rrent 110mA Maximum current 600 mA peak 1A Battery 12V 2Ah Tamper Protection IP30 Fuse Type F 5x20 mm 1A Emulated line tone 440 Hz Emulated line voltage 33Vdc Housing Plate RAL 9002 Size 200 x 260 x 4...

Страница 8: ...onth Despite frequent testing and due to but not limited to any or all of the following tampering electrical or com munication disruption or improper use it is possible for the product system to fail...