background image

 

 

50D0111 

RCSITEA Installation & Operating Manual         

Rel 1.0  April 2009 

   Page 1 of 10 

                                     Ambient Technologies 

A Division Of  Monessen Hearth Systems

 

 

 

RCSITEA 

Thermostatic On/Off, Flame Height Adjustment and Blower 

Remote Control– 120VAC 

 

INSTALLATION AND OPERATING INSTRUCTIONS 

 

CAUTION: The RCSITEA is only certified to be used on vented heater rated equipment. 

 
This remote control system provides a safe, reliable and user-friendly remote control for millivolt valve gas 
appliances, blower speed and flame height adjustment.  The system can be manually or thermostatically turned on 
and off with the transmitter.  Always check the appliance home owner’s manual for additional information, or 
warnings regarding accessory installation before connecting this remote control system. 
 
Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately contact the 
dealer from whom you purchased the kit or Ambient Technologies Technical Support  at 1 800 398 6195.  Do not 
attempt to install any part of the kit unless all parts are in good condition.  Please keep this booklet for future 
reference. 
 
Please check the gas type of the unit to match the current  

 

CONTENTS OF KIT  

 

Description Qty 

Transmitter 1 
Battery Alkaline AAA (for Transmitter) 

Receiver (Assembly)  consists of : 

Receiver Box 

 

AC Adaptor for Receiver 

 

SIT Stepper Motor 

Slide Button-Black (On/RS/Off) 

Wall Cover Plate-Black 

Wire Nuts 

Plug-In Wiring Assembly for SIT mV Valve– 22” Inches 

Plug-In Wiring Assembly for SIT Hi/Lo Regulator – 10” Inches 

Velcro (Loop and Hook) 

Installation Instructions 

#8 Screw for sheet metal, Black  

 

 

FEATURES/SPECIFICATIONS 

 

 

Easy Access Thermostatic Control 

 

Battery Powered Transmitter  

 

Low battery Indication for Transmitter  

 

Compact 120 VAC Adapter with 30” Wire 

 

Three Speed Control for Blower with Blower Type Selection 

 

Three Flame Height Settings 

 

Programmable Timer to Turn Blower on and Off 

 

Child Proof Lock-out 

 

16 Security Codes 

 

6 hour Shut Down (Optional) on Receiver 

Содержание RCSITEA

Страница 1: ...om you purchased the kit or Ambient Technologies Technical Support at 1 800 398 6195 Do not attempt to install any part of the kit unless all parts are in good condition Please keep this booklet for future reference Please check the gas type of the unit to match the current CONTENTS OF KIT Description Qty Transmitter 1 Battery Alkaline AAA for Transmitter 3 Receiver Assembly consists of 1 Receiver...

Страница 2: ...nty NOTE Due to the sensitive temperature monitoring components in the transmitter it is necessary to allow the transmitter to stabilize to room temperature before accurate room temperatures are displayed If the transmitter is activated from a severe cold condition allow 15 minutes for accurate temperature readings to appear on the LCD display WARNING Turn appliance OFF and allow to cool before in...

Страница 3: ...pliance Your appliance may have other options to connect wiring from receiver For applications longer than 22 inches use 18 gauge wire 105ºC rated with no splices Connect to the two 2 1 4 female spade wiring terminals and wire can be no longer than 20 feet WARNING Speed control module and thermal sensor must be removed before installing receiver and applying the AC power Failure to do so may cause...

Страница 4: ...TOP Make sure 120VAC fan and SIT valve are correct If not wired correctly this could cause damage to receiver Make sure that the wires do not contact the appliances any place other than at the terminals Exposure to temperatures higher than 105C 250ºF may cause the receiver to malfunction and cause possible fire hazard SIT mV Valve Hi Lo Regulator ...

Страница 5: ... DIP switches are preset at the factory In the event of activation or interference from other nearby transmissions reset the code using the following procedures 1 There are four switches on the transmitter and seven switches on the receiver see figure below Switches 1 2 3 and 4 on both transmitter and receiver are privacy switches and 5 6 7 on the receiver are blower switches 2 Slide the privacy c...

Страница 6: ... set to temperature ranges between 45 F and 90 F The blower speed and flame height can be adjusted in either the manual and thermostatic mode The transmitter will operate the remote receiver from 1foot to a maximum of 30 feet The distance is reduced when batteries are low or when the receiver is inside a metal enclosure Initial Start up 1 After initial power up or when RESET button is pressed the ...

Страница 7: ...Press FAN button once to enter blower speed setup mode at low speed initially and one of the three blade icon will display darken on LCD display 2 Continue to press FAN button to set up the blower speed you desire 3 If there is no input within 3 seconds the new setting will be transmitted to receiver If fireplace is on the blower speed will take effect right away if fireplace is off the receiver w...

Страница 8: ...not operate with low batteries Change the batteries before the batteries are too weak for normal operation TURN THE UNIT OFF BEFORE REPLACING BATTERIES Child Proof Protection 1 Press and hold the ON and OFF buttons simultaneously for 3 seconds to enter childproof mode as shown in this picture 2 The transmitter will not send a signal again until childproof mode is deactivated by pressing the ON and...

Страница 9: ...or location of the switches 2 In the event that the blower runs too slow or too fast on Low or Medium change the blower switch setting to achieve desired speed levels 3 Turn on the blower at Low speed with the transmitter and start from STEP 1 ON ON OFF then follow the following steps in the chart below to set up the blower switches The blower speed will decrease when going through the steps Stop ...

Страница 10: ... the main gas flame should extinguish but the pilot light will remain on 4 Slide the button to RS the center position then press the ON button on transmitter to turn the system ON The main gas flame should ignite and blower should come on after the On Delay Time is reached and fan speed you desire is selected 5 Press the OFF button on transmitter to turn the system to OFF The flame should extingui...

Страница 11: ...orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARRANTY This warranty gives you specific legal rights and you may also have other rights that vary from state to state or provin...

Страница 12: ...50D0111 RCSITEA Installation Operating Manual Rel 1 0 April 2009 Page 12 of 10 Ambient Technologies A Division Of Monessen Hearth Systems CALL 800 398 6195 ...

Отзывы: