AMB8426-M_8626-M_MA_EN_V2_4
Page 18 of 48
Released: Nov.2013
ID: 0x12345678
Version: 0x00
Device type: Water (0x03)
Key (LSB first):
0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C 0x0D 0x0E
0x0F
Telegram:
0xFF
0x50
0x18
0xA2 0x05 0x78 0x56 0x34 0x12 0x00 0x03
0x00 0x01 0x02 0x03 0x04
0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C 0x0D 0x0E 0x0F
0x1B
7.13.2 CMD_CLR_AES_KEY_REQ
This command can be used to delete an AES-key.
Format:
0xFF
0x51
0x08 <Address of device> <CS>
Return:
0xFF
0xD1
0x01 <Status> <CS>
Status:
0x00: success
0x01: verification in memory failed
0x02: the meter could not be found in the list
7.13.3 CMD_GET_AES_DEV_REQ
With this command the addresses of all registered devices can be read. The addresses are
saved in 4 banks (0x00, 0x01, 0x02, 0x03). These banks have to be called up one after the
other.
Format:
0xFF
0x52
0x01 < Bank > < CS >
Return:
0xFF 0xD2 0x80 < registered addresses > < CS >
Example:
Prompt of bank 0:
0xFF
0x52
0x01 0x00 0xAC
Answer from the registration in chapter 7.13.1:
0xFF
0xD2
0x80 0xA2 0x05 0x78 0x56 0x34 0x12 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x01