GreenDrill 3.2 on-board computer
GreenDrill BAH0054-4 02.13
39
6.12
Faults
WARNING
Risk of crushing, shearing, cutting, being caught and/or drawn
in, or impact through
Unintentional lowering of the machine raised using the
tractor's three-point hydraulic system.
Unintentional lowering of raised, unsecured machine parts.
Unintentional start-up and rolling away of the tractor-
machine combination.
Secure the tractor and the machine against unintentional start-up and
rolling before eliminating any faults on the machine.
Wait for the machine to stop before entering the danger area of the
machine.
Fault messages
No display on the screen
after switching on the on-
board computer.
Testing points:
Is the power cable attached correctly to the on-board computer?
Check the fuse
Check the cable connections to the battery poles.
Status message
Display
Cause
Troubleshooting
01
Operating voltage is too low
Reduce consumer
Check the battery and cables
Check the alternator
02
Operating voltage is too high
Check the alternator
03
Internal control voltage is too low
Contact customer services
04
The sowing shaft is blocked
Switch off the device.
Remove any foreign objects
from the seed drill and agitator shaft.
05
The sowing shaft motor is de-energised.
Check the connector and cable
06
The sowing shaft motor is properly con-
nected and is not blocked, but does not
rotate.
Contact customer services
07
The blower fan motor is blocked
Switch off the device.
Remove any foreign objects
from the blower fan.
08
Wiring is incorrect or not even connected.
Check the wiring and connector.
09
The blower fan motor is properly con-
nected and is not blocked, but does not
rotate
Contact customer services