Adjustments
8.3
Adjusting the stripper
The strippers are set at the factory. To adjust the
setting to the working conditions:
1. Loosen the bolts.
2. Adjust the stripper in the slot.
3. Tighten the bolts again.
Wedge ring rollers:
Do not adjust the distance between
stripper and spacer ring to less than
10 mm to avoid excessive wear.
Tooth packer roller:
Adjust the distance between the
scraper and shaft between 0.5 to
4 mm.
Cenius 03 BAG0144.5 10.19
63
Содержание Cenius 3003