The Amazon is designed to communicate with any data logger over SDI-12. The SDI-12 menu
simply lets you set its SDI-12 address. The Amazon bubbler has internal data logging capabilities.
By default the internal logging is disabled but can be enabled, and the logging rate set in the
Logging / Data menu. The data log file can include its own scanned data and or the stage when a
measurement is requested via SDI-12 or Modbus. Within the Logging / Data menu, the Logging
Inclusions setting can be set to ‘All Data’ or ‘Scanned Data’. In the ‘All Data’ mode, the Amazon will
log stage at its own logging rate, and also when requested over SDI-12 or Modbus. In the Scanned
Data mode the Amazon will only log stage at its own logging rate. These options can be useful as
backups to your SDI-12 or Modbus data requests. All data is copied when requested and All data
is erased when requested. The event log can also be copied. See the manual for more information
on 4-20mA and Modbus communication options.
Communication