background image

THE WEB INTERFACE

12

To connect directly to the Amazon, the supplied USB device cable can be used. The first use of 
the device cable will require a simple driver to be installed for communication. After the driver has 
been installed, a new network connection will be established with the Amazon. This typically occurs 
within ten seconds. Once the network has been established, open a web browser and navigate to 

http://172.20.20.20/

. If the connection was successful, the Amazon’s user interface will appear in 

the browser window. 

Windows 7 Driver Installation

 

As the drivers will not be automatically discovered, the driver will need to be manually in-

stalled. This can be done through the Device Manager. To open the Device Manager, first navi-
gate to the Control Panel, then System and Security > System > Device Manager (or just System 
> Device Manager if using classic icons).  Look for a device labeled RNDIS with an exclamation 
mark next to it. Right click on the RNDIS label and select Update Driver Software. Select “Browse 
my computer for the driver software”. Click the option to “Let me pick from a list of device drivers 
on my computer.”  On the device type screen, choose “Network adapters” and click next.  On the 
Select Network Adapter screen, select “Microsoft Corporation” as the Manufacturer followed by 
“Remote NDIS Compatible Device” as the network adapter.  Click Next.  A warning will appear stat-
ing that Windows cannot verify that the driver is compatible with your hardware.  Click Yes to install 
it anyway and the driver installation is complete.

The driver only needs to be installed on the first connection for this device. After the driver has 
finished, disconnect and reconnect the USB device cable to initialize the network connection. Once 
the connection has been established, open a web browser and navigate to 

http://172.20.20.20/.

USB Cable Connection

Содержание BUBBLER 361755REF

Страница 1: ...Amazon Bubbler GETTING STARTED GUIDE Item 361755REF REVC...

Страница 2: ...Installation 14 Basic SDI 12 Commands 16 This guide is a brief overview of the Amazon Bubbler and its basic features Updated manuals new firmware updates brochures technical notes and supporting softw...

Страница 3: ...1 GET TO KNOW YOUR AMAZON 01...

Страница 4: ...re to produce a constant bubble rate A battery operated compressor maintains the tank pressure When unpacking your Amazon make sure all the components ordered are received and undamaged from Shipping...

Страница 5: ...he power requirments the Amazon should only be powered from the sites main power source Ethernet The Ethernet port is a 10 100 BaseT port allowing the Amazon to connect to a Local Area Network or a Wi...

Страница 6: ...to work properly NOTE All buttons on the top panel are ca pacitive buttons and therefore may not work if using gloves Display and Control Buttons The display is not a touch screen it s a very low pow...

Страница 7: ...5 BASICSETUP USINGTHEDISPLAY 02...

Страница 8: ...and time navigate to the System Setup Menu and press Enter Main Menu The Home Screen displays the current stage and units of measure It also displays the date and time of the last measurement the live...

Страница 9: ...ve the highlighter sequentially left to right changing the desired characters by scrolling up and down through the options Once you re satisfied with the setting scroll to the right or left to move Sy...

Страница 10: ...8 COMMUNICATION 03...

Страница 11: ...us Within the Logging Data menu the Logging Inclusions setting can be set to All Data or Scanned Data In the All Data mode the Amazon will log stage at its own logging rate and also when requested ove...

Страница 12: ...10 THEWEBINTERFACE 04...

Страница 13: ...eshed every few seconds Simply touch a network to connect to it A checkmark will appear next to the network once a connection has been made Open the Safari web browser and navigate to http 172 20 20 2...

Страница 14: ...tem Device Manager if using classic icons Look for a device labeled RNDIS with an exclamation mark next to it Right click on the RNDIS label and select Update Driver Software Select Browse my computer...

Страница 15: ...Home Screen You can set Site ID Date and Time Bubbler Screen You can set your Units of Measure Offset and the Stage value SDI 12 Screen You can set the Amazon s SDI 12 address Data Screen You can set...

Страница 16: ...14 INSTALLATION 05...

Страница 17: ...r the NPT threads threads that are screwed into the aluminum block on the Amazon only Securely tighten the fitting into the Amazon The Ferrell set should be fitted on an orifice tube with a clean cut...

Страница 18: ...BASICSDI 12 COMMANDS 06 16...

Страница 19: ...To verify the stage reading send the aM measurement command to the Amazon Wait approximately 11 seconds and then send the aD0 data command to verify the data retrieved compares with the following exa...

Страница 20: ...ildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications exp...