SAFETY DIRECTIONS 

Basic Directions

 

This control has been built in accordance with 

EN 12453 Industrial, commercial and 

garage doors and gates - Safety in use of power operated doors - Requirements and EN 
12978 Industrial, commercial and garage doors and gates - Safety devices for power 
operated doors - Requirements and Test methods; 

and left the factory in perfect condition from 

the point of view of safety. To maintain this condition and to ensure safe operation, the user must 
observe all the directions and warnings contained in these operating instructions. 
In principle, only trained electrical technician should work on electrical equipment. They must assess the 
work which has been assigned to them, identify potential danger sources and take suitable safety 
precautions. 

Reconstruction of or changes to CP 970 or the SE 14.21 operator are only permissible with the 

approval of the manufacturer. Original replacement parts and accessories authorized by the 
manufacturer guarantee safety. Liability ceases to apply if other parts are used.  The operational 
safety of the unit is only guaranteed if it is used in accordance with the regulations. The limiting 
values stated in the technical data should not be exceeded under any circumstances (see 
corresponding sections of the operating instructions). 

Specified normal use 

The drive unit is intended for counter-balancing sectional doors.  The safe operation is only 

guaranteed with normal specified use. The drive unit is to be protected from rain, moisture and 
aggressive ambient conditions. No liability for damage caused by other applications or non-
observance of the information in the manual. 

Spare parts 

Use only original spare parts. 

  Symbols 

Warning - This warns that the SE14.21 or other materials may be damaged if 
the appropriate precautions are not taken.   

Danger - This indicates danger to the life and health of the user if the 
appropriate precautions are not taken.  
Note - Important information! 

Содержание SE14.21 CP 970

Страница 1: ...Wolf eEN n en e Installation Instructions SE 14 21 25 40 ER CP970 115VAC 1PH Date 21 10 2013 Version 1 1 SE115V 1PH...

Страница 2: ...f themanufacturer Original replacement parts and accessories authorized by the manufacturer guarantee safety Liability ceases to apply if other parts are used The operational safety of the unit is onl...

Страница 3: ...AND MOTOR CONNECTION 6 ELECTRICAL CONNECTIONS 7 SETTING THE LIMITS 8 WIRING THE ACCESSORIES 9 PROGRAMMING THE UNIT 10 OPERATING STATUS DISPLAY 13 MANUAL OPERATION 14 HARDWARE OVERVIEW 15 WIRING DIAGR...

Страница 4: ...nt 2 6 AMPS Operating frequency 60 Hz Maximum movement per hour 16 Class of protection IP 65 Fuses 1 x 2AMP Secondary 1 x 1AMP Accessories Temperature range 5 40 C Operator Dimensions Control Panel en...

Страница 5: ...ing the Operator The descriptions below apply to general door specifications The specifications of the door manufacturer must also be observed during installation Warning During installation be sure t...

Страница 6: ...lace 4 Remove motor cover 5 Verify wiring of motor cables Note After verifying proper connections re instal limit and motor cover Electrical i nstallati on Danger Switch the power OFF and check that t...

Страница 7: ...edicated 15AMP outlet within 3 of control panel Motor cable connection to operator control panel overview Fit cable through the provided strain relief Wire motor cables into CP 970 panel Limit cable c...

Страница 8: ...t Push Hold the STOP button for 3 seconds until the display changes C Program the CLOSE limit Push Hold the CLOSE button to close the door to the desired close final limit position Memorise the CLOSE...

Страница 9: ...o install a normally closed contact photocell to the CP 970 If not used Jumper 6 1 6 2 B Safety Edge It is recommended to install a normally closed contact Safety Edge to the CP 970 If used with photo...

Страница 10: ...ry close without installing a Safety Photocells and or Safety Edge Dead man OPEN Dead man CLOSE Momentary OPEN Dead man CLOSE Momentary OPEN Momentary CLOSE Do Not Use Press Selector Door Position Fin...

Страница 11: ...switch contact position Off Not used Switch contact impulse signal Switch contact continuous Pre Flash Open Close 3 seconds with flash on movement Pre Flash Close three seconds with flash on movement...

Страница 12: ...ck Info cycle counter 7 digit selector M HT ZT T H Z E The cycles would be displayed as follow M 1 000 000 H 100 HT 100 000 Z 10 ZT 10 000 E 1 Info last 2 faults selector Last 2 faults would be altern...

Страница 13: ...onnecting cable are not broken Consult factory Limits not adjusted Adjust limits Safety open limit operated Turn mains supply OFF and move the door downwards with the manual operator until the limit i...

Страница 14: ...opped at lower limit Note If any other fault codes appear please consult factor 9 MANUAL OPERATION ER release The manual operation is provided as a means of opening or closing the door when power is u...

Страница 15: ...5 1 5 2 4 Photocell or Safety edge N C If not used Jumper 6 1 6 2 5 Radio control N O 7 1 7 2 6 Jumper Do not remove 3 1 3 2 7 Selector switch 8 7 Segment display 9 Relay output for warning light or a...

Страница 16: ...16 12 ACCESSORIES WIRING DIAGRAM...

Страница 17: ...25mm SOCKET HEAD CAO SCREW X2 29 EMERGENCY RELEASE 30 ROPE EXTENSION 31 MOUNTING BRACKET 32 STRAIN RELIEF PART DESCRIPTION 1 ENCLOSURE 2 CP970 CONTROLLER 3 CONTACTOR 24VAC 4 FUSE HOLDER 5 FUSE 2 AMP...

Страница 18: ...18...

Отзывы: