manualshive.com logo in svg
background image

 

MDR300-0-0-AC-02 

September 2010 

Page 12 

 

3. 

On acceptance of the change, the Status LED will change to Green. 

4. 

If the change is rejected the Status LED will change to Red. 

Entering a Facility Code 

A Facility Code only applies when PIN-codes are used.  It is reported as part of the 
Wiegand code and can be used to link a set of Multi-discipline Readers to a particular 
Site.  

A Facility Code can be entered into the Reader's memory.  To set the Facility Code, do 
the following: 

1. 

Press and hold down key '1' for 3 seconds.  The Status LED will enter a fast flash 
Amber Mode. 

2. 

Enter the Facility Code in the range 0 to 255 and finish by pressing the Hash Key 
(#). 

3. 

On acceptance of the Facility Code the Status LED will briefly change to Green 
and the Buzzer will sound. 

4. 

If the Facility Code is rejected the Status LED will change to Red for a longer 
period and the Buzzer will sound. 

Power-on Self-test 

The Power-on Self-test tests the RAM and Flash Checksums. 

If any parameter in the Self-test fails, the Multi-discipline Reader emits a continuous 
beep for 2 seconds.   

When the Multi-discipline Reader passes the Self-test, it emits two short beeps, each 
200 ms in duration, separated by a 200 ms inter-beep pause. 

When the Multi-discipline Reader is connected, check that the Status LED is illuminated 
Red (steady).  This will confirm that the connection is correct and working. 

Serial Number Label 

1. 

Once the Multi-discipline Reader is installed, sketch a rough site plan.   

2. 

Attach the Multi-discipline R

eader‟s loose Serial Number Label and the Terminal or 

Controller‟s Fixed Address Label, to the sketched site plan in the position of the 
Multi-discipline Reader.   

The Multi-discipline Reader does not have its own Fixed Address.  When connected to 
a Terminal or Controller the Multi-discipline Reader is assigned one of the available 
Fixed Addresses.  

The Serial Number Label identifies the type of Multi-discipline Reader, and the Fixed 
Address Label (shipped with the Terminal or Controller) identifies the Fixed Addresses.  
Both these labels should be attached to the site plan to assist in identifying the 
hardware once an Auto-ID is performed.  

GUARANTEE OR WARRANTY 

This product conforms to our Guarantee or Warranty details placed on our Web Site, to 
read further please go to www.amano.com. 

 

 

 

Содержание MDK900-5-0-AC Series

Страница 1: ...similar to IP54 The Multi discipline Readers are therefore sealed potted against water Input Voltage Rating 8 V DC to 14 V DC polarity sensitive Power Requirements Current mA Power W Supply Voltage 1...

Страница 2: ...onnect the Purple and Gray wires to a Dry Contact Input On Amano Systems it is unnecessary to connect these lines as the Software handles the Anti tamper MDK900 model only Keypad 12 Alphanumeric keys...

Страница 3: ...Communications Distance Install the Multi discipline Readers no further than 150 m 164 yd from the Host unit The cable individual conductor cross sectional area should not be less than 0 2 mm 2 0 000...

Страница 4: ...tember 2010 Page 4 ELECTRICAL CONNECTIONS Connecting the Multi discipline Reader Figure 1 to Figure 5 show typical connections for the Multi discipline Reader Figure 1 Multi discipline Reader Connecte...

Страница 5: ...MDR300 0 0 AC 02 September 2010 Page 5 Figure 2 Multi discipline Reader Connected to the Nexus 220 Controller...

Страница 6: ...MDR300 0 0 AC 02 September 2010 Page 6 Figure 3 Multi discipline Reader Connected to the Amano MfT...

Страница 7: ...MDR300 0 0 AC 02 September 2010 Page 7 Figure 4 Multi discipline Reader Connected to the Amano TA or Amano iTA...

Страница 8: ...MDR300 0 0 AC 02 September 2010 Page 8 Figure 5 Multi discipline Reader Connected to the Amano RL Amano RS and Amano RH...

Страница 9: ...M Use Only The Multi discipline Readers offer four different Output Mode Combinations Select the Output Mode by doing the following 1 On the back of the Multi discipline Reader locate and bridge the t...

Страница 10: ...utton Keypad is used to enter 5 digit PIN codes in the range 00000 to 65535 Wiegand protocol constraints disallow PIN codes from 65536 to 99999 In this case the Status LED turns Red and the Buzzer act...

Страница 11: ...is entered for the key buffer length then the Key Mode reverts to PIN Mode 3 On acceptance of the setting the Status LED changes to Green 4 If the settings are rejected the Status LED changes to Red...

Страница 12: ...beep for 2 seconds When the Multi discipline Reader passes the Self test it emits two short beeps each 200 ms in duration separated by a 200 ms inter beep pause When the Multi discipline Reader is co...

Страница 13: ...MDR300 0 0 AC 02 September 2010 Page 13 USER NOTES...

Страница 14: ...MDR300 0 0 AC 02 September 2010 Page 14 USER NOTES...

Страница 15: ...MDR300 0 0 AC 02 September 2010 Page 15 USER NOTES...

Страница 16: ...arters 140 Harrison Avenue Roseland NJ 07068 1239 800 526 2559 www amano com This manual is applicable to the Amano Multi discipline Readers MDR900 5 0 AC 06 and MDK900 5 0 AC 06 The last two digits o...

Отзывы: