Amana Room Air Conditioner & Heat Pump Скачать руководство пользователя страница 16

16

How to set:

Press the 

TIMER 0.5-24 hr 

pad on the unit or the

TIMER 

pad

on the remote control. Each touch of the 

INCREASE 

/ DECREASE

   pads on the unit or the 

INCREASE (+) /

DECREASE (-)

 pads on the remote control will set the

timer in 0.5 (1/2 hr.) or 1-hour intervals. (The delay timer

can be set in 0.5 (1/2 hr.) increments if programmed for

under 10 hours, but if the delay timer is set for above 10

hours, the timer will be set in 1-hour increments.)  The

SET 

light will turn on while setting.

To review the remaining time ,

press the 

TIMER  0.5-24 hr

 pad on the unit or the TIMER pad

on the remote control. Use the 

INCREASE 

/ DE-

CREASE

  pads on the unit or the 

INCREASE (+) /

DECREASE (-)

 pads on the remote control to set a new

time if desired.

To cancel the timer, press and hold the 

TIMER 

 

0.5

-24 hr

pad until the light on the 

 

TIMER

 

0.5

-24 hr pad goes off.

u

Swing Pad

Turn on to provide continuous side-to-side air circulation.

For fixed side-to-side air direction, turn on until the de-

sired air direction is obtained, then turn it off.

Remote Control:

To ensure proper operation, aim the remote control at

the signal receiver on the air conditioner.

The remote control signal has a range of up to 20 feet.

Make sure nothing is between the air conditioner and

the remote control that could block the signal.

Make sure your batteries are fresh and installed cor-

rectly as indicated on the remote control.

Cool Mode

Use the 

COOL

 mode at 

LOW, MED, HIGH, 

or

 AUTO

FAN SPEED 

for cooling.  Use the 

TEMPERATURE IN-

CREASE 

/ DECREASE 

pads to set the desired

temperature between 61° and 86°F in 1° increments.
The compressor will cycle on and off to keep the room at

the set level of comfort. Set the thermostat at a lower

number and the indoor air will become cooler. Set the

thermostat at a higher number and the indoor air will be-

come warmer.

NOTE: 

If the air conditioner is off and then turned on

while set to a 

COOL

 setting, or if it is turned from a fan

setting to a 

COOL

 setting, it may take approximately 3

minutes for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling - 

Select the 

COOL

 mode and 

HIGH

or 

MED

 fan with a middle set temperature.

For Maximum Cooling - 

Select the 

COOL 

mode and

HIGH

 fan with a lower set temperature.

For  Quieter & Nighttime Cooling - 

Select the 

COOL

mode and 

LOW

 fan with a middle set temperature.

Energy Saver Mode

Controls the fan.

ON 

The fan will cycle on and off with the compressor.

This results in wider variations of room temperature
and humidity and is normally used when the room is
unoccupied.

NOTE: 

The fan may continue to run for a short time after

the compressor cycles off.

OFF - 

The fan runs all the time, while the compressor

cycles on and off.

Fan Only Mode

Use the 

FAN ONLY 

mode at 

LOW, MED 

or 

HIGH

 fan

speed to provide air circulation and filtering without cool-

ing.  Since the fan only settings do not provide cooling, a

SET

 temperature cannot be entered. The room tempera-

ture will appear in the display.

NOTE:

 Auto Fan Speed cannot be used when in the 

FAN

ONLY 

mode.

Heat Mode (on some models)

Use the 

HEAT 

mode at 

LOW, MED, HIGH 

or 

AUTO FAN

SPEED 

for heating.  Use the 

TEMPERATURE INCREASE

/ DECREASE 

pads to set the desired tempera-

ture between 61°F and 86°F in 1°F increments.

Auto Fan Speed

Set to 

AUTO

 fan speed for the fan speed to automati-

cally set to the speed needed to provide optimum com-

fort settings with the set temperature. If the room needs

more cooling, the fan speed will automatically increase.

If the room needs less cooling, the fan speed will auto-

matically decrease.

NOTE: 

Auto Fan Speed cannot be used when in the 

FAN

ONLY 

mode.

Power Outage Recovery Feature

In the case of a power outage or interruption, the unit will

automatically re-start in the settings last used, after the

power is restored.  If the 

TIMER 0.5-24 hr

 feature was set,

it will resume countdown.  You may need to set a new

time if desired.

Содержание Room Air Conditioner & Heat Pump

Страница 1: ...counter problems during installation call our consumerinformationlinetoll freeat1 877 376 0214 If your problem cannot be resolved by phone contact an authorizedAmana brandservicer Contactandservice will be at your expense IO 372A 2010GoodmanCompany L P Effective May2010 SafetyInformation Besureelectricalserviceisadequateforchosenmodelofair conditioner Complete electrical rating for unit is found o...

Страница 2: ...sreceiptforfuturereference Youmay alsowanttorecordinthespaceprovidedthedatepurchased and the selling dealer OWNER S PRODUCT IDENTIFICATION MODEL NUMBER SERIAL NUMBER MANUFACTURING NUMBER Owner s Name Address City State Zip Date of Purchase Authorized Dealer Address City State Zip Phone Number To avoid death personal injury or property damage due to electrical shock Observe all local codes and ordi...

Страница 3: ...d with your unit Unit without a window mounting kit No window mounting kit is supplied with the unit These models are designed for mounting through an opening in a wall These units can be adapted to windowinstallationbypurchasinganoptionalwindow mountingkit Consultyourdealertochoosethekitthat is appropriate for your model and installation RoomHeatPumps Heatpumpsworkbymovingheatinsteadofcreatingit ...

Страница 4: ...terbyreversingremovalprocedure Front Grille and Cabinet Cleaning Grille and cabinet may be cleaned with warm water and mild soapordetergent Cleaningandpolishingcompoundsarenot recommended as they may damage plastic surfaces Air Filter Cleaning A dirty air filter reduces operating efficiency of unit Filter should be inspected at least once every week during opera tion Clean filter with vacuum clean...

Страница 5: ...om the indoor air condensate is channeled to the outdoor side of the unit The outdoor fan blade has a slinger ring attachedtoitthatdipsintothewaterandslingsthewateronto the outdoor coil surface This is the sound of water you hear duringnormaloperation Thewaterquicklyevaporatesonthis warmsurfaceandimprovestheefficiencyofyourairconditioner In normal conditions the unit can evaporate the water as fas...

Страница 6: ...y fuse or circuit breaker Thesemodelsshouldbeinstalledon their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a possible fire hazard from overheating wires CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this air conditioner Alu...

Страница 7: ...p mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 4 Type C 7 Type E Bolt 2 nuts 2 PARTS INCLUDED Appearance may vary Installation Instructions Type D 6 Type E 4 Type F 2 Installation Instructions ...

Страница 8: ...H Long enough to fit inside the window frame THICKNESS Todeterminethethickness placea piece of wood on the stool to make it 1 2 higher than the top of the storm window frame Attach securely with nails or screws provided by the installer 2 STORM WINDOW REQUIREMENTS Remove the locking screw and locking bracket from the lower frame Save to reinstalllater Remove the ground screw and save to reinstalll...

Страница 9: ...ews Drill pilot holes if necessary Make sure the bolts and nuts are all of the way in both the left and right V supports Position the V supports on the case bottom so that they will be near the outside wall Attach a V support to each side of the bottom of the case using type C screws 3 on each side C B A 6 Bolt and nut V support 4 type E screws S tool Make sure the bolts and nuts are all of the wa...

Страница 10: ...ertical window sashes Drill pilot holes and attach the top and bottom corners with 4 type D screws F E D 6 Type D screw Type D screw Type D screw Top mounting rail Type D screw INSTALL SUPPOR T BRACKETS AND THE FOAM TOP WINDOW GAS KET Attach the support brackets with two type D screws one on each side Cut the foam top window gasket to the window width Stuff the foam between the glass and the windo...

Страница 11: ... the air discharge area Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case Push the grille frame in And install the 2 side screws at bottom left and right side of front panel Secure the front grille frame to the case with one type C screw Reinstall the filter Reinstall the inlet grille Connect power J I H G 8 Guide the le...

Страница 12: ...ve carpentry and or masonry experience Thru wall installations performed by inexperienced or unqualified individuals can result in costly damage to home or result in equipment malfunction that could cause property damage personal injury or death CAUTION Air Conditioner Dimensions The following figures show the outside dimensions of air conditioner with chassis installed and dimensions of outer cas...

Страница 13: ...ming lumber 26 1 8 17 Framed Finished Opening brick veneer or frame wall construction Placement of Outer Case in Opening Place outer case in opening flush against one side of opening Use carpenter s level and ensure case is level from side to side and has a 3 8 inch slope from front to back back of case must be 3 8 inch lower than front to ensure proper condensate drainage If needed use shims to l...

Страница 14: ... 9 inches The side louvers in outer case provide ventilation to air con ditioner compressor and fan motor and must not be blocked When installing unit in a wall over 9 inches thick provisions must be made in wall opening to ensure free air flow to the side louvers This can be accomplished by chamfering the vertical portions of the outside opening as shown Ventilation louvers on top of case must no...

Страница 15: ...n the unit or the INCREASE DECREASE pads on the remote control will set the delay time when using the TIMER 0 5 24 hr The SET light will turn on while setting r FanSpeedPads Use to set the fan speed to LOW MED HIGH or AUTO on the unit NOTE On the remote control use the fan speed IN CREASE DECREASE pads to set the fan speeds to LOW MED or HIGH Use the AUTO pad to turn Auto fan on s Mode Pad Use to ...

Страница 16: ...s off and then turned on while set to a COOL setting or if it is turned from a fan setting to a COOL setting it may take approximately 3 minutes for the compressor to start and cooling to begin Cooling Descriptions For Normal Cooling Select the COOL mode and HIGH or MED fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH fan with a lower set temperature For Quieter ...

Страница 17: ...g or adding condensate drain cup Check with dealer to determine proper capacity unit for application MOUNTING SUPPORT NOT INSTALLED Storm window frame installed in window Some models require removal of storm window frame before installation FROST ON INDOOR COIL Dirty air filter Normal for low outdoor temperatures Clean air filter by vacuuming or washing with water and mild soap Turning Temperature...

Страница 18: ... enclosed with unit Keep accurate records of service calls including what was done servicer s name and date of service AnyQuestions Mostquestionscanbeansweredbyyourlocaldealer Ifyou have other matters that cannot be resolved locally or you need additional information regarding other heating and cooling products offered by us please call CONSUMERINFORMATIONLINE AMANATOLLFREE 1 877 376 0214 U S and ...

Страница 19: ... locate an authorized Amana brand servicer contact Goodman Company Consumer Affairs at the number or address found at the bottom of this certificate Goodman will not pay for electricity or fuel costs or increases in electricity or fuel costs for any reason including additional or unusual use of supplemental electric heat This warranty does not cover lodging WARRANTY LIMITATIONS WE ARE NOT RESPONSI...

Страница 20: ...ctive part must be returned to an Amana brand heating and air conditioning products distributor by an authorized Amana brand servicer and all warranty service must be performed by an autho rized Amana brand servicer To locate an authorized Amana brand servicer contact Goodman Company Consumer Affairs at the number or address found at the bottom of this certificate Model Serial ____________________...

Отзывы: