Amana Room Air Conditioner & Heat Pump Скачать руководство пользователя страница 1

 

is a registered trademark of Maytag Corporation or its related companies

and is used under license to Goodman Company, L.P., Houston, TX.  All rights reserved.

Room Air Conditioner & Heat Pump

Use and Care Manual

Introduction

Room air conditioners cool, dehumidify, and filter air inside

your home.  Heat pump and electric heat models offer both

heating and cooling.  Opening sections of manual provide

general information for all room air conditioner models.

Operating Controls

 section describes operation of controls

for each model.  After reading the opening sections, turn to

Operating Controls

 section and find the panel layout that

matches the model of your unit.
Read entire manual thoroughly before beginning installation

and operation of your new room air conditioner.  Be sure you

have all necessary tools and materials on hand for the job.

Study illustrations to familiarize yourself with important

details of the installation process.  Review manual for oper-

ating instructions.

NOTE

1. Mechanical experience is required to install air condi-

tioner.

2. Installation can take from 1 to 3 hours, depending on

installer’s knowledge and skill.

3. If you encounter problems during installation, call our

consumer information line toll-free at 1-877-376-0214.  If

your problem cannot be resolved by phone, contact an

authorized Amana

®

 brand servicer.  Contact and service

will be at your expense.

IO-372A

©2010 Goodman Company,  L.P.

Effective: May 2010

Safety Information

Be sure electrical service is adequate for chosen model of air

conditioner. Complete electrical rating for unit is found on

serial plate located behind front grille. Electrical outlet must

be close enough to unit for power cord to reach without strain.

Air conditioner should be the only appliance on individual

circuit.
For personal safety and to avoid possible damage to appli-

ance or home, observe all safety instructions highlighted by

symbol shown below.

RECOGNIZE THIS SYMBOL AS A

SAFETY PRECAUTION.

After installing unit, reread instructions to ensure each step

is complete and that all parts are fastened in place. For best

results and to minimize installation time, perform all proce-

dures in the order shown.

WARNING

Contents

Introduction .................................................................. 1

Safety Information ....................................................... 1

Unpacking .................................................................... 2

Electrical Requirements .............................................. 2

Installation ................................................................... 3

Room Heat Pumps ....................................................... 3

Normal Care & Maintenance ...................................... 3

General Instructions .................................................... 5

Installation Instructions ............................................... 6

Through-The-Wall Installation Instructions ............. 12

Operating Controls .................................................... 15

Before Calling Service .............................................. 17

When Service Is Required ........................................ 18

Any Questions? .......................................................... 18

Warranty ..................................................................... 20

Содержание Room Air Conditioner & Heat Pump

Страница 1: ...counter problems during installation call our consumerinformationlinetoll freeat1 877 376 0214 If your problem cannot be resolved by phone contact an authorizedAmana brandservicer Contactandservice will be at your expense IO 372A 2010GoodmanCompany L P Effective May2010 SafetyInformation Besureelectricalserviceisadequateforchosenmodelofair conditioner Complete electrical rating for unit is found o...

Страница 2: ...sreceiptforfuturereference Youmay alsowanttorecordinthespaceprovidedthedatepurchased and the selling dealer OWNER S PRODUCT IDENTIFICATION MODEL NUMBER SERIAL NUMBER MANUFACTURING NUMBER Owner s Name Address City State Zip Date of Purchase Authorized Dealer Address City State Zip Phone Number To avoid death personal injury or property damage due to electrical shock Observe all local codes and ordi...

Страница 3: ...d with your unit Unit without a window mounting kit No window mounting kit is supplied with the unit These models are designed for mounting through an opening in a wall These units can be adapted to windowinstallationbypurchasinganoptionalwindow mountingkit Consultyourdealertochoosethekitthat is appropriate for your model and installation RoomHeatPumps Heatpumpsworkbymovingheatinsteadofcreatingit ...

Страница 4: ...terbyreversingremovalprocedure Front Grille and Cabinet Cleaning Grille and cabinet may be cleaned with warm water and mild soapordetergent Cleaningandpolishingcompoundsarenot recommended as they may damage plastic surfaces Air Filter Cleaning A dirty air filter reduces operating efficiency of unit Filter should be inspected at least once every week during opera tion Clean filter with vacuum clean...

Страница 5: ...om the indoor air condensate is channeled to the outdoor side of the unit The outdoor fan blade has a slinger ring attachedtoitthatdipsintothewaterandslingsthewateronto the outdoor coil surface This is the sound of water you hear duringnormaloperation Thewaterquicklyevaporatesonthis warmsurfaceandimprovestheefficiencyofyourairconditioner In normal conditions the unit can evaporate the water as fas...

Страница 6: ...y fuse or circuit breaker Thesemodelsshouldbeinstalledon their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a possible fire hazard from overheating wires CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this air conditioner Alu...

Страница 7: ...p mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 4 Type C 7 Type E Bolt 2 nuts 2 PARTS INCLUDED Appearance may vary Installation Instructions Type D 6 Type E 4 Type F 2 Installation Instructions ...

Страница 8: ...H Long enough to fit inside the window frame THICKNESS Todeterminethethickness placea piece of wood on the stool to make it 1 2 higher than the top of the storm window frame Attach securely with nails or screws provided by the installer 2 STORM WINDOW REQUIREMENTS Remove the locking screw and locking bracket from the lower frame Save to reinstalllater Remove the ground screw and save to reinstalll...

Страница 9: ...ews Drill pilot holes if necessary Make sure the bolts and nuts are all of the way in both the left and right V supports Position the V supports on the case bottom so that they will be near the outside wall Attach a V support to each side of the bottom of the case using type C screws 3 on each side C B A 6 Bolt and nut V support 4 type E screws S tool Make sure the bolts and nuts are all of the wa...

Страница 10: ...ertical window sashes Drill pilot holes and attach the top and bottom corners with 4 type D screws F E D 6 Type D screw Type D screw Type D screw Top mounting rail Type D screw INSTALL SUPPOR T BRACKETS AND THE FOAM TOP WINDOW GAS KET Attach the support brackets with two type D screws one on each side Cut the foam top window gasket to the window width Stuff the foam between the glass and the windo...

Страница 11: ... the air discharge area Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case Push the grille frame in And install the 2 side screws at bottom left and right side of front panel Secure the front grille frame to the case with one type C screw Reinstall the filter Reinstall the inlet grille Connect power J I H G 8 Guide the le...

Страница 12: ...ve carpentry and or masonry experience Thru wall installations performed by inexperienced or unqualified individuals can result in costly damage to home or result in equipment malfunction that could cause property damage personal injury or death CAUTION Air Conditioner Dimensions The following figures show the outside dimensions of air conditioner with chassis installed and dimensions of outer cas...

Страница 13: ...ming lumber 26 1 8 17 Framed Finished Opening brick veneer or frame wall construction Placement of Outer Case in Opening Place outer case in opening flush against one side of opening Use carpenter s level and ensure case is level from side to side and has a 3 8 inch slope from front to back back of case must be 3 8 inch lower than front to ensure proper condensate drainage If needed use shims to l...

Страница 14: ... 9 inches The side louvers in outer case provide ventilation to air con ditioner compressor and fan motor and must not be blocked When installing unit in a wall over 9 inches thick provisions must be made in wall opening to ensure free air flow to the side louvers This can be accomplished by chamfering the vertical portions of the outside opening as shown Ventilation louvers on top of case must no...

Страница 15: ...n the unit or the INCREASE DECREASE pads on the remote control will set the delay time when using the TIMER 0 5 24 hr The SET light will turn on while setting r FanSpeedPads Use to set the fan speed to LOW MED HIGH or AUTO on the unit NOTE On the remote control use the fan speed IN CREASE DECREASE pads to set the fan speeds to LOW MED or HIGH Use the AUTO pad to turn Auto fan on s Mode Pad Use to ...

Страница 16: ...s off and then turned on while set to a COOL setting or if it is turned from a fan setting to a COOL setting it may take approximately 3 minutes for the compressor to start and cooling to begin Cooling Descriptions For Normal Cooling Select the COOL mode and HIGH or MED fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH fan with a lower set temperature For Quieter ...

Страница 17: ...g or adding condensate drain cup Check with dealer to determine proper capacity unit for application MOUNTING SUPPORT NOT INSTALLED Storm window frame installed in window Some models require removal of storm window frame before installation FROST ON INDOOR COIL Dirty air filter Normal for low outdoor temperatures Clean air filter by vacuuming or washing with water and mild soap Turning Temperature...

Страница 18: ... enclosed with unit Keep accurate records of service calls including what was done servicer s name and date of service AnyQuestions Mostquestionscanbeansweredbyyourlocaldealer Ifyou have other matters that cannot be resolved locally or you need additional information regarding other heating and cooling products offered by us please call CONSUMERINFORMATIONLINE AMANATOLLFREE 1 877 376 0214 U S and ...

Страница 19: ... locate an authorized Amana brand servicer contact Goodman Company Consumer Affairs at the number or address found at the bottom of this certificate Goodman will not pay for electricity or fuel costs or increases in electricity or fuel costs for any reason including additional or unusual use of supplemental electric heat This warranty does not cover lodging WARRANTY LIMITATIONS WE ARE NOT RESPONSI...

Страница 20: ...ctive part must be returned to an Amana brand heating and air conditioning products distributor by an authorized Amana brand servicer and all warranty service must be performed by an autho rized Amana brand servicer To locate an authorized Amana brand servicer contact Goodman Company Consumer Affairs at the number or address found at the bottom of this certificate Model Serial ____________________...

Отзывы: