ACCESSORY INSTALLATIONS
29
Fuse Kit
Fuse Holder Kit
Description
This optional fuse holder kit can be installed directly in the
chassis or in the optional subbase.
Fuse holder kits are available in 230/208 volt ratings. The
installer should supply time delay fuses at 15, 20, 25 or 30
amps in accordance with the “Maximum Overcurrent Pro-
tection” as listed on the unit nameplate. Fuses may be
purchased from the parts department.
Installation
The installation and servicing of the equipment referred to in
this booklet should be performed by qualified, experienced
technicians.
U
SE
COPPER
CONDUCTORS
ONLY
FOR
ELECTRICAL
CONNECTIONS
. T
HE
USE
OF
OTHER
TYPES
OF
CONDUCTORS
MAY
RESULT
IN
GAL
-
VANIC
CORROSION
,
OVERHEATING
AND
RESUL
-
TANT
EQUIPMENT
FAILURE
.
CAUTION
A
LL
WIRING
MUST
COMPLY
WITH
APPLICABLE
LOCAL
AND
NATIONAL
CODES
. T
YPE
AND
LOCATION
OF
FUSED
DISCONNECT
SWITCH
(
ES
)
MUST
COMPLY
WITH
ALL
APPLICABLE
CODES
.
F
AILURE
TO
FOLLOW
THESE
CODES
COULD
RESULT
IN
OVERHEATING
AND
EQUIPMENT
FAILURE
.
Fuse Holder Kit Installation (Without Subbase)
See page 27 for installation in a subbase.
C
F
H
X X
Fuseholder
Fuseholder
Line 1 Heater Heater Line 2 Comp
Fan
High
Fan
Low
Rev.
Valve
Electronic Board
Capacitor
BK-10
RD-10
Unit Electrical
Connector
Fuse Holder Diagram
Control Panel Installation
1. Remove front by rotating bottom outward and then lifting
up and out from chassis.
2. To gain access inside the control panel, after removing
the knobs and escutcheon, remove the two screws hold-
ing panel in position. Tilt control panel forward, being
careful not to pinch any wires.
3. As viewed from the front, remove both knockouts on the
control panel.
4. Insert two fuse holders from the front. The fuse holders
should be oriented so the quick-connect tabs are to-
ward the center of the unit. Attach fuse holders using
the screws and nuts provided.