ACCESSORY INSTALLATIONS
12
15. Place a hose clamp over one end of the 11 inch long
hose. Push this same end over the longer leg of the
overflow tube and secure with the hose clamp. Place
another hose clamp over the other end of the 11 inch
hose. Push this same end over the condensate tube
protruding out from the back of the partition panel and
secure with the hose clamp.
16. Route the condensate pump cord through the U clip on
the condenser shroud, through the p-clamp attached to
the brace, and then through the hole in the panel where
the compressor wires are routed through the panel.
NOTE:
The permagum may have to be removed to feed
the wires through the panel, make sure wires have no
slack and replace the permagum back into place to pre-
vent air leaks.
1
2
3
O N
SCREW
SCREW
SCREW
Transformer
Mounting Holes
Relay Mounting
Holes
Back Of Escutcheon
19. Using two #8 screws that are provided, screw the trans-
former to the control panel in the transformer mounting
holes provided in the panel. (See figure above.)
20. Mount the relay in one of the three relay mounting holes
in the control panel making sure that the threaded stud
is in the smaller hole and the metal tab is in the adja-
cent larger hole. Screw the provided nut onto the threaded
stud from the opposite side of the control panel.
21. Disconnect the RD33, VT12, and BK19 wires from the
control board and connect the YL5 (where RD33 was
connected), YL3 (where VT12 was connected), and YL1
(where BK19 was connected). Connect RD33 to the
piggyback terminal of YL5, VT12 to the piggyback ter-
minal of YL3, and BK19 to the piggyback terminal of
YL1. Make sure the OR8 wire is connected from the #6
terminal of the relay to 24 volt terminal of the transformer.
22. For 208 volt applications move the WH6 wire terminal
from the 240 volt terminal of the transformer to the 208
terminal of the transformer.
23. Units that have a Power Vent or Power Door Kit already
installed in the chassis should refer to the proper wiring
schematic for proper wiring of the condensate pump kit.
Use the second set of transformer holes to mount the
transformer.
24. Units that have a 2 stage heater already installed in the
chassis should refer to the proper wiring schematic for
proper wiring of the condensate pump kit.
25. Units that have a Power Vent or Power Door Kit and a
two stage heater already installed in the chassis should
refer to the proper wiring schematic for proper wiring of
the condensate pump kit.
26. Install the basepan drain plug into the basepan drain
hole by pushing it up into the drain hole from the bottom
of the basepan. This will defeat the thermostatic con-
trolled drain valve. The basepan drain is located left of
the outside coil (as viewed from the back of the unit).
NOTE:
When using a condensate removal pump, extra care
must be taken to keep the basepan clean and free of algae
or fungus. Failure to do so may result in the failure of the
condensate removal system.