I. Safety Information

Important

To The Installer
Before installing this unit please read this manual and
the Specification Sheet to familiarize  yourself on the
specific items which must be adhered to such as maxi-
mum external static pressure to unit, air temperature
rise, minimum or maximum CFM and motor speed con-
nections.

To The Owner
It is important to complete the owner registration card
and mail it immediately. This will assist Amana in con-
tacting you if any service or warranty information should
change in the future. When completing the registration
card, be sure to include the Model, Manufacturing and
Serial Numbers, plus the installation date.

The warranty certificate is also supplied with the unit.
Read the warranty carefully and note what is covered.
Keep the warranty certificate in a safe place so you can
find it if necessary.

If additional operating instructions are required, call the
dealer where the purchase was made. Keep this litera-
ture in a safe place for future reference.

WARNING

To prevent death, personal injury or prop-
erty damage due to fire or explosion,
installation procedures in this manual
must be followed exactly.

WARNING

Should overheating occur or the gas sup-
ply fail to shut off, turn off the manual
gas control valve to the unit before shut-
ting off the electrical supply.

WARNING

To prevent death, personal injury or prop-
erty damage,  do not use this unit if any
part of the unit has been under water.
Immediately call a qualified service tech-
nician to inspect the unit and to replace
any part of the control system and any
gas control which has been under water.

If you smell gas:

• Do not try to light appliance.
• Do not touch any electrical switch: do not use

any phone in building.

• Immediately call gas supplier from a neighbor’s

phone. Follow gas supplier’s instructions.

• If gas supplier cannot be reached, call fire de-

partment.

WARNING

To prevent death, personal injury, or
property damage due to improper instal-
lation, adjustments, alterations, service
or maintenance, when servicing or per-
forming maintenance to this unit consult
this manual, service manual, qualified
installer, service agency or gas supplier.

WARNING

This product contains or produces a
chemical(s) which may cause death or
serious illness and which are known by
the State of California to cause cancer,
birth defects or other reproductive harm.

IMPORTANT NOTE: This unit must not be used as a
“construction heater” during the finishing phases
of construction on a new structure. This type of use
may result in premature failure of the unit due to
extremely low return air temperatures and exposure
to very dirty atmospheres.

Содержание PGB**C

Страница 1: ...afety practices follow them The precautions listed in this Installation Manual should not supersede existing practices but should be considered as supplemental information ATTENTION INSTALLING PERSONN...

Страница 2: ...shut off turn off the manual gas control valve to the unit before shut ting off the electrical supply WARNING To prevent death personal injury or prop erty damage do not use this unit if any part of t...

Страница 3: ...rn air entering the unit must be between 50 F and 100 F Provisions must be made for adequate combustion and ventilation air in accordance with Section 5 3 Air for Combustion and Ventilation of the Nat...

Страница 4: ...ht bill or indemnity in lieu thereof c Original invoice or certified copy thereof showing trade and other discounts or reductions d Copy of the inspection report issued by carrier representative at th...

Страница 5: ...propane gas and for altitude adjust ments Piping IMPORTANT NOTE To avoid possible unsatisfactory operation or equipment damage due to under firing of equipment do not undersize the natural propane ga...

Страница 6: ...ring which may result in heat failure This unit and its shut off valve must be disconnected from the gas supply dur ing any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 48...

Страница 7: ...er gas pressure depends on three main factors 1 Vaporization rate which depends on a tempera ture of the liquid and b wetted surface area of the container or containers 2 Proper pressure regulation 3...

Страница 8: ...re 5 V Electrical Wiring Locating The Thermostat Thermostat should be mounted 5 feet above the floor on a vibration free inside wall in a room or a hallway that has good air circulation Movement of ai...

Страница 9: ...sformer primary lead and induced draft blower mo tor leads as shown on the unit wiring diagram Heat Anticipator Setting The heat anticipator in the room thermostat must be correctly adjusted to obtain...

Страница 10: ...duct should be provided with an access panel This access should be large enough to inspect the air chamber downstream from the heat exchanger for any smoke or combustion gas leaks A cover should be ti...

Страница 11: ...ocated and other spaces of the building Turn on clothes dryers and any appliance not connected to the common venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they w...

Страница 12: ...ll Out Protector Figure 9 Rollout Protection IX Heating Sequence of Operations Normal Sequence of Operation Heating 1 Thermostat calls for heat The combustion blower is immediately energized 2 The pre...

Страница 13: ...Figure 12 With Power And Gas On 2 Put unit into heating cycle and turn on all other gas consuming appliances Figure 12 Measuring Inlet Gas Pressure Alternate Method Secondary Limit Control On the PGB...

Страница 14: ...per cubic foot as deter mined by Step 2 then Input 1000 x 3600 0 34 106 000 BTU per Hour NOTE BTU content of the gas should be obtained from the gas supplier This measured input must not be greater t...

Страница 15: ...ishing phases of construction on a new struc ture This type of use may result in pre mature failure of the unit due to extremely low return air temperatures and expo sure to very dirty atmospheres To...

Страница 16: ...d with water thoroughly dried and sprayed with a filter adhesive before being reinstalled Filter adhesives may be found at many hardware stores Permanent filters should last several years However shou...

Страница 17: ...sonal injury due to electrical shock do not remove any in ternal compartment covers or attempt any adjustment Contact a qualified ser vicer at once if an abnormal flame ap pearance should develop At l...

Страница 18: ...ng Flame Roll Out Switch Blower Motor Gas Orifice Blower Wheel Heat Exchanger Burner High Limit Switch Compressor Secondary Limit Condenser Coil Ignitor Flame Sensor Condenser Fan Blade Induced Draft...

Отзывы: