Operating Instructions

RS4110001 Rev. 0

14

Using Air Conditioner

NOTE: If unit is turned off, wait 3 minutes before

restarting. This will allows pressure inside the
compressor to equalize. Failure to follow these
instructions may cause inefficient operation.

WARNING

!

To avoid risk of fire, electric shock, or personal injury,
read IMPORTANT SAFETY INSTRUCTIONS before
operating this appliance.

To begin operating air conditioner, follow these
steps:
1.  Plug in air conditioner.

NOTE: To avoid electrical hazards, do not use an

extension cord or adapter plug.

2.  Place exhaust vent to 

CLOSED

 position.

3.  Turn TEMPERATURE CONTROL knob to highest

number setting or 

COLDER 

setting.

4.  Turn FAN CONTROL knob to 

COOL MODE

 

HIGH

setting.

5.  Adjust louvers for comfortable air circulation.
6.  Once room has cooled, turn temperature control knob

to setting more comfortable.

Air Conditioner Features

Controls featured in this manual represent 82VS and
102VS models.

Fan Control Knob

Turns unit on, off, and allows you to select either cooling
air, or allows air to circulating at existing temperature.
Operate FAN ONLY and COOL MODE according to the
following suggestions:

Mode

Function

OFF

Turns unit off.

HIGH COOL

Maximum cooling speed, start unit in
this mode.

MED COOL

Moderate cooling speed.

LOW COOL

Minimum cooling speed.

HIGH FAN

Maximum air circulation speed.

MED FAN

Moderate air circulation speed.

LOW FAN

Minimum Air circulation speed.

LOW

MED

HIGH

FAN    CONTROL

HIGH

MED

LOW

OFF

 FAN
ONLY

COOL
MODE

Temperature Control Knob

When any COOL MODE setting is selected, thermostat
controls the amount of cooling by automatically turning
cooling compressor on and off in response to room
temperature.
Turn TEMPERATURE CONTROL knob to highest
number for the coldest cooling setting. Once room
reaches desired temperature, adjust TEMPERATURE
CONTROL knob to desired number comfortable for
cooling room.

ECONOMY
SETTINGS

1

2

3

4

5

6

7

8

COL

D

ER

TEMPERATURE    CONTROL

NOTE: Higher numbers provide lower room

temperatures. Lower numbers provide higher
room temperatures.

Vent Control Knob

Allows unit to either recirculate inside air 

CLOSED

, or

exhaust air to the outside 

EXHAUST

.

• 

CLOSED

 position is used when maximum cooling is

desired. It may also be used for air recirculation
without cooling when air conditioner is turned to FAN
ONLY position.

• 

EXHAUST

 position removes stale air from the room,

and exhausts it to the outside. Fresh air is drawn into
the room through normal air passages found in
homes.

• 

The 

EXHAUST

 or 

CLOSED

 position can be used with

any fan selection.

VENT    CONTROL

CLOSED

EXHAUST

Содержание P1212701R

Страница 1: ...nd manufacturing numbers in this manual 8V2S P1212701R 10V2S P1212702R This manual is to be used by qualified appliance technicians only Amana does not assume any responsibility for property damage or...

Страница 2: ...14 Air Conditioner Features 14 Fan Control Knob 14 Temperature Control Knob 14 Vent Control Knob 14 Air Directional Louvers 15 Night Time Cooling 15 Care and Cleaning Instructions Winter Storage 16 A...

Страница 3: ...t you must assume responsibility for any personal injury or property damage which may result Amana will not be responsible for any injury or property damage arising from improper service and or servic...

Страница 4: ...ninsulated electrical terminals connectors heaters ect are adequately spaced away from all metal parts and panels All safety grounds are correctly and securely connected All panels are properly and se...

Страница 5: ...8 8 Watts Cooling 760 1050 Fuse Breaker Delay 15 Amps 15 Amps Receptacle Code A 15 Air Flow System Capacitor MFD Volts 5 370 15 370 RPM CFM EVAP High 1100 235 1375 305 RPM CFM EVAP Medium 900 185 114...

Страница 6: ...buse of the plug can result in electrical shock or overheating For your personal safety this appliance must be grounded This air conditioner includes a power supply cord with a three prong grounding p...

Страница 7: ...f the window where the unit will be installed Be sure it will support the weight of the unit This appliance must be installed according to all applicable codes and ordinances Handle the air conditione...

Страница 8: ...his angle installed Figures B C show alternate treatments On the sash side of the opening the leading corner of the inner sash becomes the flange You can purchase the angle strip locally Flush 1 x1 or...

Страница 9: ...r track or stool Alternate screw location Platform tab Window track Window seal CAUTION To avoid risk of property damage be sure the wood stool or window track is securely attached to the building con...

Страница 10: ...nt on the plastic window panel along the longer side 10 Clamp plastic window panel between a board and work table cut along the line with a fine tooth saw Remove any burrs with a file 11 Fasten side c...

Страница 11: ...frame does not fit snugly to inner window sash secure panel frame to the sash with 8x3 4 inch screws or 8 32x3 4 inch self threading screws Use partially plugged holes in panel frame to drill 1 8 inc...

Страница 12: ...bolt Support brace 1 4 hex flange nut NOTE If planning to use siding protection on the outside of the house hold the board in place when testing assembly in the window 2 Drill a 9 64 inch diameter pi...

Страница 13: ...embly Pinch off excess length so the seal is even with the bottom of cabinet side channel 12 Remove front panel frame and filter Remove 2 screws securing front panel frame in place Press down on top e...

Страница 14: ...COOL Maximum cooling speed start unit in this mode MED COOL Moderate cooling speed LOW COOL Minimum cooling speed HIGH FAN Maximum air circulation speed MED FAN Moderate air circulation speed LOW FAN...

Страница 15: ...r to direct airflow either to the left or right Night Time Cooling When outside temperatures drop below 70 F 21 C and unit is cooling frost may form on coils and block air flow into room If this occur...

Страница 16: ...of cabinet 2 Push front panel down and pull toward forward to release front panel from retaining lock 3 Gently pull filter forward off of clips 4 Wash filter using a liquid detergent and warm water Ri...

Страница 17: ...power company All units will operate and run on minimum voltage stated in Air Conditioning Voltage Limits and will perform satisfactorily if voltage remains constant Low voltage caused by defective wi...

Страница 18: ...l Fan Motor Condenser air flow restriction Condenser fins damaged Capacitor Wiring Refrigerant system Insufficient cooling Low Capacity Air filter Exhaust door open Unit undersized Excessive noise Eva...

Страница 19: ...itor 8 Remove control panel 9 Remove vent door actuator arm 10 Remove screws securing control box to bulkhead 11 Remove compressor and fan motor leads from control box and remove control box 12 Remove...

Страница 20: ...1 Rev 0 20 Component Location Illustrations Cabinet front panel Rear grille Cabinet wrapper Vertical louver Dial plate Control knobs Filter Control box Door vent Capacitor Capillary tube Fan control T...

Страница 21: ...Disassembly Procedures RS4110001 Rev 0 21 Fan blade Fan motor Blower wheel Blower housing Fan housing Compressor Evaporator Condensor Evaporator tray...

Страница 22: ...lack BR Brown R Red W White G GND Ribbed Blue R R W S BK C Start Assist Compressor Capacitor Fan Capacitor BR Compressor BK R R S W Fan Motor Compressor Overload Room Thermostat R BL BK W BK L1 3 1 2...

Отзывы: