Installation Instructions

RS4110001 Rev. 0

13

6.  Securely attach siding-protection board to the side of

the house.

Inside
wall of
house

Siding
protection
board

NOTE: Siding-protection board should be long enough

to span 2 wall studs.

7.  Measure distance from the top of platform assembly

to top of window opening. Subtract 20 1/2 to
20 5/8-inches. Mark this measurement on the plastic
window panel, along the longer side.

8.  Clamp plastic window panel between a board and

work table, cut along the line with a fine tooth saw.
Remove any burrs with a file.

9.  Fasten side channels to unit using 3 screws per

channel. Start with the first screw at the top of the
channel. Verify hook ends of the channels face
toward back of the unit.

10. Slide plastic window panel into panel frame, with

smooth side to the room. Slide panel frame assembly
into side channels of the air conditioner cabinet.
Verify plastic window panel is firmly enclosed on all
sides by retainer grooves.

11. Cut side channel seal into 2 equal lengths. Remove

protective backing and apply to rear side of cabinet
side channels, starting just below panel frame
assembly. Pinch off excess length so the seal is even
with the bottom of cabinet side channel.

12. Remove front panel frame and filter. Remove 2

screws securing front panel frame in place. Press
down on top edge of front panel frame, tilt forward,
and lift up off the bottom spring clips. Remove filter.

Clips

Filter

NOTE: DO NOT push or pull the air direction louvers.

13. Place unit into the window opening on platform

assembly. Place window panel frame, and cabinet
side channels against the top and side window
jambs.

Slide inner
window sash
frimly against
cabinet

14. Drill two 9/64-inch diameter pilot holes in top of

window jamb in line with the partially plugged holes in
panel frame. Secure panel frame to window jamb
with two #8-32x3/4-inch self-threading screws. If
additional holding is necessary, two screws may be
used on the sides of panel frame.

15. Drill two screw-clearance holes in cabinet side

channels (near bottom) and two 9/64-inch diameter
pilot holes in side window jambs. Secure cabinet side
channels to window jambs with two #8-32x3/4-inch
self-threading screws.

NOTE: Be careful not to twist side channel seals.

Inserting screws will prevent unit from being
pushed into the room.

16. Replace unit front panel frame and filter. Replace

screws that hold the panel in place. Do not push or
pull front panel louvers.

Содержание P1212701R

Страница 1: ...nd manufacturing numbers in this manual 8V2S P1212701R 10V2S P1212702R This manual is to be used by qualified appliance technicians only Amana does not assume any responsibility for property damage or...

Страница 2: ...14 Air Conditioner Features 14 Fan Control Knob 14 Temperature Control Knob 14 Vent Control Knob 14 Air Directional Louvers 15 Night Time Cooling 15 Care and Cleaning Instructions Winter Storage 16 A...

Страница 3: ...t you must assume responsibility for any personal injury or property damage which may result Amana will not be responsible for any injury or property damage arising from improper service and or servic...

Страница 4: ...ninsulated electrical terminals connectors heaters ect are adequately spaced away from all metal parts and panels All safety grounds are correctly and securely connected All panels are properly and se...

Страница 5: ...8 8 Watts Cooling 760 1050 Fuse Breaker Delay 15 Amps 15 Amps Receptacle Code A 15 Air Flow System Capacitor MFD Volts 5 370 15 370 RPM CFM EVAP High 1100 235 1375 305 RPM CFM EVAP Medium 900 185 114...

Страница 6: ...buse of the plug can result in electrical shock or overheating For your personal safety this appliance must be grounded This air conditioner includes a power supply cord with a three prong grounding p...

Страница 7: ...f the window where the unit will be installed Be sure it will support the weight of the unit This appliance must be installed according to all applicable codes and ordinances Handle the air conditione...

Страница 8: ...his angle installed Figures B C show alternate treatments On the sash side of the opening the leading corner of the inner sash becomes the flange You can purchase the angle strip locally Flush 1 x1 or...

Страница 9: ...r track or stool Alternate screw location Platform tab Window track Window seal CAUTION To avoid risk of property damage be sure the wood stool or window track is securely attached to the building con...

Страница 10: ...nt on the plastic window panel along the longer side 10 Clamp plastic window panel between a board and work table cut along the line with a fine tooth saw Remove any burrs with a file 11 Fasten side c...

Страница 11: ...frame does not fit snugly to inner window sash secure panel frame to the sash with 8x3 4 inch screws or 8 32x3 4 inch self threading screws Use partially plugged holes in panel frame to drill 1 8 inc...

Страница 12: ...bolt Support brace 1 4 hex flange nut NOTE If planning to use siding protection on the outside of the house hold the board in place when testing assembly in the window 2 Drill a 9 64 inch diameter pi...

Страница 13: ...embly Pinch off excess length so the seal is even with the bottom of cabinet side channel 12 Remove front panel frame and filter Remove 2 screws securing front panel frame in place Press down on top e...

Страница 14: ...COOL Maximum cooling speed start unit in this mode MED COOL Moderate cooling speed LOW COOL Minimum cooling speed HIGH FAN Maximum air circulation speed MED FAN Moderate air circulation speed LOW FAN...

Страница 15: ...r to direct airflow either to the left or right Night Time Cooling When outside temperatures drop below 70 F 21 C and unit is cooling frost may form on coils and block air flow into room If this occur...

Страница 16: ...of cabinet 2 Push front panel down and pull toward forward to release front panel from retaining lock 3 Gently pull filter forward off of clips 4 Wash filter using a liquid detergent and warm water Ri...

Страница 17: ...power company All units will operate and run on minimum voltage stated in Air Conditioning Voltage Limits and will perform satisfactorily if voltage remains constant Low voltage caused by defective wi...

Страница 18: ...l Fan Motor Condenser air flow restriction Condenser fins damaged Capacitor Wiring Refrigerant system Insufficient cooling Low Capacity Air filter Exhaust door open Unit undersized Excessive noise Eva...

Страница 19: ...itor 8 Remove control panel 9 Remove vent door actuator arm 10 Remove screws securing control box to bulkhead 11 Remove compressor and fan motor leads from control box and remove control box 12 Remove...

Страница 20: ...1 Rev 0 20 Component Location Illustrations Cabinet front panel Rear grille Cabinet wrapper Vertical louver Dial plate Control knobs Filter Control box Door vent Capacitor Capillary tube Fan control T...

Страница 21: ...Disassembly Procedures RS4110001 Rev 0 21 Fan blade Fan motor Blower wheel Blower housing Fan housing Compressor Evaporator Condensor Evaporator tray...

Страница 22: ...lack BR Brown R Red W White G GND Ribbed Blue R R W S BK C Start Assist Compressor Capacitor Fan Capacitor BR Compressor BK R R S W Fan Motor Compressor Overload Room Thermostat R BL BK W BK L1 3 1 2...

Отзывы: